메뉴 건너뛰기




Volumn 30, Issue 5, 2002, Pages 603-607

Correct positioning of the venous Port-A-Cath catheter: Comparison of intravascular electrocardiography signal from guidewire and sodium bicarbonate flushed catheter

Author keywords

ECG: Guidewire, sodium bicarbonate, Port A Cath, intravascular; Monitoring

Indexed keywords

ANESTHETIC AGENT; BICARBONATE;

EID: 0036798431     PISSN: 0310057X     EISSN: None     Source Type: Journal    
DOI: 10.1177/0310057x0203000510     Document Type: Article
Times cited : (12)

References (23)
  • 1
    • 0028925323 scopus 로고
    • Central venous catheters. Placement and monitoring tips
    • Kahn JK. Central venous catheters. Placement and monitoring tips. Postgrad Med 1995; 97:65-68.
    • (1995) Postgrad. Med , vol.97 , pp. 65-68
    • Kahn, J.K.1
  • 2
    • 0028276049 scopus 로고
    • Bilateral hydrothorax caused by left external jugular venous catheter
    • Ho CM, Lui PW. Bilateral hydrothorax caused by left external jugular venous catheter. J Clin Anesth 1994; 6:243-246.
    • (1994) J. Clin. Anesth , vol.6 , pp. 243-246
    • Ho, C.M.1    Lui, P.W.2
  • 3
    • 0027305715 scopus 로고
    • Superior vena cava thrombosis related to catheter malposition in cancer chemotherapy given through implanted ports
    • Puel V, Caudry M, Le Metayer P et al. Superior vena cava thrombosis related to catheter malposition in cancer chemotherapy given through implanted ports. Cancer 1993; 72:2248-2252.
    • (1993) Cancer , vol.72 , pp. 2248-2252
    • Puel, V.1    Caudry, M.2    Le Metayer, P.3
  • 4
    • 0032828317 scopus 로고    scopus 로고
    • Central venous catheter mechanical irritation of the right atrial free wall: A cause for thrombus formation
    • Fuchs S, Pollak A, Gilon D. Central venous catheter mechanical irritation of the right atrial free wall: A cause for thrombus formation. Cardiology 1999; 91:169-172.
    • (1999) Cardiology , vol.91 , pp. 169-172
    • Fuchs, S.1    Pollak, A.2    Gilon, D.3
  • 5
    • 0029965830 scopus 로고    scopus 로고
    • Accurate placement of central venous catheters using right atrial electrocardiography
    • Takebe S, Mashima Y, Yamamoto K, Yufu K, Hidaka H, Aono H. Accurate placement of central venous catheters using right atrial electrocardiography. Masui 1996; 45:326-330.
    • (1996) Masui , vol.45 , pp. 326-330
    • Takebe, S.1    Mashima, Y.2    Yamamoto, K.3    Yufu, K.4    Hidaka, H.5    Aono, H.6
  • 6
    • 0023010666 scopus 로고
    • EKG guided placement of subclavian CVP catheters using J-wire
    • Starr DS, Cornicelli S. EKG guided placement of subclavian CVP catheters using J-wire. Ann Surg 1986; 204:673-676.
    • (1986) Ann. Surg , vol.204 , pp. 673-676
    • Starr, D.S.1    Cornicelli, S.2
  • 8
    • 0023870474 scopus 로고
    • Right atrial electrocardiography in placement of central venous catheters
    • Wilson RG, Gaer JA. Right atrial electrocardiography in placement of central venous catheters. Lancet 1988; 27:462-463.
    • (1988) Lancet , vol.27 , pp. 462-463
    • Wilson, R.G.1    Gaer, J.A.2
  • 9
    • 0342684473 scopus 로고    scopus 로고
    • Use of electrocardiogram to position right atrial catheters during surgery
    • Watters VA, Grant JP. Use of electrocardiogram to position right atrial catheters during surgery. Ann Surg 1997; 225:165-171.
    • (1997) Ann. Surg , vol.225 , pp. 165-171
    • Watters, V.A.1    Grant, J.P.2
  • 10
    • 0028001650 scopus 로고
    • Right atrial electrocardiography: A technique for the placement of central venous catheters for chemotherapy or intravenous nutrition
    • Madan M, Shah MV, Alexander DJ, Taylor C, McMahon MJ. Right atrial electrocardiography: a technique for the placement of central venous catheters for chemotherapy or intravenous nutrition. Br J Surg 1994; 81:1604-1605.
    • (1994) Br. J. Surg , vol.81 , pp. 1604-1605
    • Madan, M.1    Shah, M.V.2    Alexander, D.J.3    Taylor, C.4    McMahon, M.J.5
  • 11
    • 0034181046 scopus 로고    scopus 로고
    • A novel approach of intravenous electrocardiograph technique in correct position the long-term central venous catheter
    • Cheng KI, Chu KS, Yu KL et al. A novel approach of intravenous electrocardiograph technique in correct position the long-term central venous catheter. Kaohsiung J Med Sci 2000; 16:241-247.
    • (2000) Kaohsiung J. Med. Sci , vol.16 , pp. 241-247
    • Cheng, K.I.1    Chu, K.S.2    Yu, K.L.3
  • 12
    • 0027168386 scopus 로고
    • Placement of central venous catheters by cut down with electrocardiogram positioning
    • Redo SF, Dinner MH. Placement of central venous catheters by cut down with electrocardiogram positioning. Surg Gynecol Obstet 1993; 177:49-53.
    • (1993) Surg. Gynecol. Obstet , vol.177 , pp. 49-53
    • Redo, S.F.1    Dinner, M.H.2
  • 13
    • 0031656605 scopus 로고    scopus 로고
    • Failure to attain electrocardiogram-facilitated positioning of right atrial catheters when using the Arrow antecubital central venous catheterization kit
    • Lanier WL. Failure to attain electrocardiogram-facilitated positioning of right atrial catheters when using the Arrow antecubital central venous catheterization kit. J Neurosurg Anesthesiol 1998; 10:241-243.
    • (1998) J. Neurosurg. Anesthesiol , vol.10 , pp. 241-243
    • Lanier, W.L.1
  • 14
    • 0025236450 scopus 로고
    • Incidence of arrhythmia with central venous catheter insertion and exchange
    • Stuart RK, Shikora SA, Akerman P et al. Incidence of arrhythmia with central venous catheter insertion and exchange. J Parenter Enteral Nutr 1990; 14:152-155.
    • (1990) J. Parenter. Enteral. Nutr , vol.14 , pp. 152-155
    • Stuart, R.K.1    Shikora, S.A.2    Akerman, P.3
  • 15
    • 0030357958 scopus 로고    scopus 로고
    • Cardiac arrhythmias during central venous catheter procedures in acute renal failure: A prospective study
    • Fiaccadori E, Gonzi G, Zambrelli P, Tortorella G. Cardiac arrhythmias during central venous catheter procedures in acute renal failure: a prospective study. J Am Soc Nephrol 1996; 7:1079-1084.
    • (1996) J. Am. Soc. Nephrol , vol.7 , pp. 1079-1084
    • Fiaccadori, E.1    Gonzi, G.2    Zambrelli, P.3    Tortorella, G.4
  • 16
    • 0028309744 scopus 로고
    • Sudden death after central venous cannulation
    • Quiney NF. Sudden death after central venous cannulation. Can J Anaesth 1994; 41:513-515.
    • (1994) Can. J. Anaesth , vol.41 , pp. 513-515
    • Quiney, N.F.1
  • 17
    • 0032080691 scopus 로고    scopus 로고
    • Considerations in placement of right internal jugular cannulas
    • Waters JH, Gimenez K. Considerations in placement of right internal jugular cannulas. J Clin Anesth 1998; 10:232-234.
    • (1998) J. Clin. Anesth , vol.10 , pp. 232-234
    • Waters, J.H.1    Gimenez, K.2
  • 18
    • 0026848781 scopus 로고
    • Pressure monitoring can accurately position catheters for air embolism aspiration
    • Mongan P, Peterson RE, Culling RD. Pressure monitoring can accurately position catheters for air embolism aspiration. J Clin Monit 1992; 8:121-125.
    • (1992) J. Clin. Monit , vol.8 , pp. 121-125
    • Mongan, P.1    Peterson, R.E.2    Culling, R.D.3
  • 19
    • 0030222350 scopus 로고    scopus 로고
    • Incidence and risk factors of guidewire-induced arrhythmia during internal jugular venous catheterization: Comparison of marked and plain J-wires
    • Lee TY, Sung CS, Chu YC, Liou JT, Lui PW. Incidence and risk factors of guidewire-induced arrhythmia during internal jugular venous catheterization: comparison of marked and plain J-wires. J Clin Anesth 1996 8:348-351.
    • (1996) J. Clin. Anesth , vol.8 , pp. 348-351
    • Lee, T.Y.1    Sung, C.S.2    Chu, Y.C.3    Liou, J.T.4    Lui, P.W.5
  • 21
    • 0032866834 scopus 로고    scopus 로고
    • Silicone venous access devices positioned with their tips high in the superior vena cava are more likely to malfunction
    • Petersen J, Delaney JH, Brakstad MT, Rowbotham RK, Bagley CM Jr. Silicone venous access devices positioned with their tips high in the superior vena cava are more likely to malfunction. Am J Surg 1999; 178:38-41.
    • (1999) Am. J. Surg , vol.178 , pp. 38-41
    • Petersen, J.1    Delaney, J.H.2    Brakstad, M.T.3    Rowbotham, R.K.4    Bagley C.M., Jr.5
  • 22
    • 0033624671 scopus 로고    scopus 로고
    • Cost comparison of electro-cardiography versus fluoroscopy for central venous line positioning in children
    • Tierney SN, Katke J, Langer JC. Cost comparison of electro-cardiography versus fluoroscopy for central venous line positioning in children. J Am Coll Surg 2000; 191:209-211.
    • (2000) J. Am. Coll. Surg , vol.191 , pp. 209-211
    • Tierney, S.N.1    Katke, J.2    Langer, J.C.3