메뉴 건너뛰기




Volumn 42, Issue 7, 2002, Pages 413-421

The effect of the median nerve compression test on median nerve conduction across the carpal tunnel

Author keywords

Carpal tunnel syndrome; Latencies; Median nerve compression test; Median nerve conduction; Sensitivity

Indexed keywords

ADULT; AGED; ARTICLE; CARPAL TUNNEL SYNDROME; CLINICAL ARTICLE; CLINICAL FEATURE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIAGNOSTIC VALUE; ELECTROPHYSIOLOGY; EXPERIMENTATION; FEMALE; HAND; HUMAN; MALE; MEDIAN NERVE; MEDICAL RESEARCH; MOTOR NERVE CONDUCTION; NERVE COMPRESSION; PHYSICAL EXAMINATION; PROVOCATION TEST; RELIABILITY; SENSITIVITY AND SPECIFICITY; SYMPTOM; VALIDATION PROCESS;

EID: 0036789771     PISSN: 0301150X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (32)
  • 1
    • 0027484563 scopus 로고
    • Practice parameter for electrodiagnostic studies in carpal tunnel syndrome
    • (summary statement)
    • American academy of neurology, american association of electrodiagnostic medicine, american academy of physical medicine and rehabilitation: Practice parameter for electrodiagnostic studies in carpal tunnel syndrome (summary statement). Neurology, 43: 2404-2405, 1993.
    • (1993) Neurology , vol.43 , pp. 2404-2405
  • 2
    • 0028095038 scopus 로고
    • Inter- and intra-examiner reliability of nerve conduction measurements in patients with diabetic neuropathy
    • Chaudhry, V., Corse, A., Freimer, M., Glass, J., Mellits, E., Kuncl, R., Quaskey, S., and Cornblath, D.: Inter- and intra-examiner reliability of nerve conduction measurements in patients with diabetic neuropathy. Neurology, 44: 1459-1462, 1994.
    • (1994) Neurology , vol.44 , pp. 1459-1462
    • Chaudhry, V.1    Corse, A.2    Freimer, M.3    Glass, J.4    Mellits, E.5    Kuncl, R.6    Quaskey, S.7    Cornblath, D.8
  • 3
    • 0030723386 scopus 로고    scopus 로고
    • The predictive value of electrodiagnostic studies in carpal tunnel syndrome
    • Concannon, M., Gainor, B., Petroski, G., and Puckett, C.: The predictive value of electrodiagnostic studies in carpal tunnel syndrome. Plast Reconstr Surg, 100: 1452-1458, 1997.
    • (1997) Plast Reconstr Surg , vol.100 , pp. 1452-1458
    • Concannon, M.1    Gainor, B.2    Petroski, G.3    Puckett, C.4
  • 4
    • 0025190608 scopus 로고
    • Efficacy of provocative tests for diagnosis of carpal tunnel syndrome
    • DeKrom, M.C., Knipschild, P.G., Kester, A.D.M. and Spaans, F.: Efficacy of provocative tests for diagnosis of carpal tunnel syndrome. Lancet, 335: 393-395, 1990.
    • (1990) Lancet , vol.335 , pp. 393-395
    • DeKrom, M.C.1    Knipschild, P.G.2    Kester, A.D.M.3    Spaans, F.4
  • 5
    • 0025740253 scopus 로고
    • AAEM minimonograph #14: The influence of temperature in clinical neurophysiology
    • Denys, E.: AAEM minimonograph #14: The influence of temperature in clinical neurophysiology. Muscle Nerve, 14: 795-811, 1991.
    • (1991) Muscle Nerve , vol.14 , pp. 795-811
    • Denys, E.1
  • 6
    • 0025963734 scopus 로고
    • Wrist flexion as an adjunct to the diagnosis of carpal tunnel syndrome
    • Dunnan, J. and Waylonis, G.: Wrist flexion as an adjunct to the diagnosis of carpal tunnel syndrome. Arch Phys Med Rehabil, 72: 211-213, 1991.
    • (1991) Arch Phys Med Rehabil , vol.72 , pp. 211-213
    • Dunnan, J.1    Waylonis2
  • 7
    • 0025868918 scopus 로고
    • A new diagnostic test for carpal tunel syndrome
    • Durkan, J.: A new diagnostic test for carpal tunel syndrome. J Bone Joint Surg Am, 73A, 535-538, 1991.
    • (1991) J Bone Joint Surg Am , vol.73 A , pp. 535-538
    • Durkan, J.1
  • 8
    • 0031967778 scopus 로고    scopus 로고
    • The sensitivity and specificity of tests for carpal tunnel syndrome vary with the comparison subjects
    • Gerr, F. and Letz, R.: The sensitivity and specificity of tests for carpal tunnel syndrome vary with the comparison subjects. J Hand Surg [Br], 23B: 151-155, 1998.
    • (1998) J Hand Surg [Br] , vol.23 B , pp. 151-155
    • Gerr, F.1    Letz, R.2
  • 9
    • 0031047723 scopus 로고    scopus 로고
    • Value of the carpal compression test in the diagnosis of carpal tunnel syndrome
    • Gonzales Del-Pino, J., Delgado-Martinez, A., Gonzalez, I., and Lovic A.: Value of the carpal compression test in the diagnosis of carpal tunnel syndrome. J Hand Surg [Br], 22B: 38-41, 1997.
    • (1997) J Hand Surg [Br] , vol.22 B , pp. 38-41
    • Gonzales Del-Pino, J.1    Delgado-Martinez, A.2    Gonzalez, I.3    Lovic, A.4
  • 10
    • 0027452054 scopus 로고
    • Literature review of the usefulness of nerve conduction studies and electromyography for the evaluation of patients with carpal tunnel syndrome
    • Jablecki, C., Andary, M., So, Y., Wilkins, D. and Williams, F.: Literature review of the usefulness of nerve conduction studies and electromyography for the evaluation of patients with carpal tunnel syndrome. Muscle Nerve, 16: 1392-1414, 1993.
    • (1993) Muscle Nerve , vol.16 , pp. 1392-1414
    • Jablecki, C.1    Andary, M.2    So, Y.3    Wilkins, D.4    Williams, F.5
  • 11
    • 0024519753 scopus 로고
    • Electrodiagnosis of mild carpal tunnel syndrome
    • Jackson, D. and Clifford, J.: Electrodiagnosis of mild carpal tunnel syndrome. Arch Phys Med Rehabil, 70: 199-204, 1989.
    • (1989) Arch Phys Med Rehabil , vol.70 , pp. 199-204
    • Jackson, D.1    Clifford, J.2
  • 12
    • 0018734033 scopus 로고
    • The carpal tunnel syndrome: Localization of conduction abnormalities within the distal segment of the median nerve
    • Kimura, J.: The carpal tunnel syndrome: Localization of conduction abnormalities within the distal segment of the median nerve. Brain, 102: 619-635, 1979.
    • (1979) Brain , vol.102 , pp. 619-635
    • Kimura, J.1
  • 13
    • 0031279138 scopus 로고    scopus 로고
    • Sensitivity and specificity of carpal tunnel syndrome signs
    • Kuhlman, K. and Hennessey, W.: Sensitivity and specificity of carpal tunnel syndrome signs. Am J Phys Med Rehabil, 76: 451-457, 1997.
    • (1997) Am J Phys Med Rehabil , vol.76 , pp. 451-457
    • Kuhlman, K.1    Hennessey, W.2
  • 14
    • 0000500868 scopus 로고
    • Accuracy of clinical tests used in the detection of carpal tunnel syndrome: A literature review
    • MacDermid, J.: Accuracy of clinical tests used in the detection of carpal tunnel syndrome: A literature review. J Hand Ther, 169-176, 1991.
    • (1991) J Hand Ther , pp. 169-176
    • MacDermid, J.1
  • 15
    • 0020568094 scopus 로고
    • Carpal tunnel syndrome: Median nerve stress test
    • Marin, E., Vernick, S. and Friedman, L.: Carpal tunnel syndrome: median nerve stress test. Arch Phys Med Rehabil, 64: 206-208, 1983.
    • (1983) Arch Phys Med Rehabil , vol.64 , pp. 206-208
    • Marin, E.1    Vernick, S.2    Friedman, L.3
  • 16
    • 0014500627 scopus 로고
    • Serial ulnar nerve conduction velocity measurements in normal subjects
    • McQuillen, M. and Gorin, F.: Serial ulnar nerve conduction velocity measurements in normal subjects. J Neurol Neurosurg Psychiatry, 32: 144-148, 1969.
    • (1969) J Neurol Neurosurg Psychiatry , vol.32 , pp. 144-148
    • McQuillen, M.1    Gorin, F.2
  • 21
    • 0030850381 scopus 로고    scopus 로고
    • Neurophysiological classification and sensitivity in 500 carpal tunnel syndrome hands
    • Padua, L., LoMonico, M., Gregori, B., Valente, E., Padua, R. and Tonali, P.: Neurophysiological classification and sensitivity in 500 carpal tunnel syndrome hands. Acta Neurol Scand, 96: 211-217, 1997.
    • (1997) Acta Neurol Scand , vol.96 , pp. 211-217
    • Padua, L.1    LoMonico, M.2    Gregori, B.3    Valente, E.4    Padua, R.5    Tonali, P.6
  • 22
    • 9044240862 scopus 로고    scopus 로고
    • A useful electrophysiologic parameter for diagnosis of carpal tunnel syndrome
    • Padua, L., Monaco, M., Valente, E., and Tonali, P.: A useful electrophysiologic parameter for diagnosis of carpal tunnel syndrome. Muscle Nerve, 19: 48-53, 1996.
    • (1996) Muscle Nerve , vol.19 , pp. 48-53
    • Padua, L.1    Monaco, M.2    Valente, E.3    Tonali, P.4
  • 23
    • 0022255202 scopus 로고
    • Median nerve compression test in carpal tunnel syndrome diagnosis reproduces signs and symptoms in affected wrist
    • Paley, D. and McMurtry, R.: Median nerve compression test in carpal tunnel syndrome diagnosis reproduces signs and symptoms in affected wrist. Orthopaedic review, 14: 411-415, 1985.
    • (1985) Orthopaedic Review , vol.14 , pp. 411-415
    • Paley, D.1    McMurtry, R.2
  • 24
    • 0013893339 scopus 로고
    • The carpal tunnel syndrome
    • Phalen, G.: The carpal tunnel syndrome. J Bone Joint Surg Am, 48A: 211-228, 1966.
    • (1966) J Bone Joint Surg Am , vol.48 A , pp. 211-228
    • Phalen, G.1
  • 25
    • 0015302811 scopus 로고
    • The carpal tunnel syndrome
    • Phalen, G.: The carpal tunnel syndrome. Clin Orthop, 83: 29-40, 1972.
    • (1972) Clin Orthop , vol.83 , pp. 29-40
    • Phalen, G.1
  • 27
    • 0032889292 scopus 로고    scopus 로고
    • Sensitive median-ulnar motor comparative techniques in carpal tunnel syndrome
    • Sander, H., Quinto, C., Saadeh, P. and Chokroverty, S.: Sensitive median-ulnar motor comparative techniques in carpal tunnel syndrome. Muscle Nerve, 22: 88-98, 1999.
    • (1999) Muscle Nerve , vol.22 , pp. 88-98
    • Sander, H.1    Quinto, C.2    Saadeh, P.3    Chokroverty, S.4
  • 28
    • 0024364811 scopus 로고
    • Carpal tunnel syndrome: The new 'industrial epidemic'
    • Schenck, R.: Carpal tunnel syndrome: The new 'industrial epidemic'. AAOHN Journal, 37: 226-231, 1989.
    • (1989) AAOHN Journal , vol.37 , pp. 226-231
    • Schenck, R.1
  • 29
    • 0018829026 scopus 로고
    • Slowed nerve conduction with wrist flexion in carpal tunnel syndrome
    • Schwartz, M., Gordon, J. and Swash, M.: Slowed nerve conduction with wrist flexion in carpal tunnel syndrome. Ann Neurol, 8: 69-71, 1980.
    • (1980) Ann Neurol , vol.8 , pp. 69-71
    • Schwartz, M.1    Gordon, J.2    Swash, M.3
  • 30
    • 0030810239 scopus 로고    scopus 로고
    • AAEM minimonograph #26: The electrodiagnosis of carpal tunnel syndrome
    • Stevens, J.: AAEM minimonograph #26: The electrodiagnosis of carpal tunnel syndrome. Muscle Nerve, 20: 1477-1486, 1997.
    • (1997) Muscle Nerve , vol.20 , pp. 1477-1486
    • Stevens, J.1
  • 32
    • 0026708170 scopus 로고
    • Verification of the pressure provocative test in carpal tunnel syndrome
    • Williams, T., Mackinnon, S., Novak, C., McCabe, S. and Kelly, L.: Verification of the pressure provocative test in carpal tunnel syndrome. Ann Plast Surg, 29: 8-11, 1992.
    • (1992) Ann Plast Surg , vol.29 , pp. 8-11
    • Williams, T.1    Mackinnon, S.2    Novak, C.3    McCabe, S.4    Kelly, L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.