메뉴 건너뛰기




Volumn 17, Issue 7, 2002, Pages 820-825

The effect of partial or full weight bearing ambulation after cementless total hip arthroplasty

Author keywords

Bone ingrowth fixation; Femoral prosthesis; Fully porous coated; Postoperative weight bearing; Total hip arthroplasty (THA)

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; FOLLOW UP; FRACTURE FIXATION; FUNCTIONAL ASSESSMENT; HIP RADIOGRAPHY; HUMAN; INTRAOPERATIVE PERIOD; MALE; MOBILIZATION; POSTOPERATIVE PERIOD; PROSTHESIS; SURGICAL TECHNIQUE; TOTAL HIP PROSTHESIS; TREATMENT OUTCOME; TREATMENT PLANNING; WEIGHT BEARING;

EID: 0036789393     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1054/arth.2002.34809     Document Type: Article
Times cited : (45)

References (13)
  • 1
    • 0027221789 scopus 로고
    • Cemented versus cementless total hip arthroplasty: A comparative study of equivalent patient populations
    • Hozack WJ, Rothman RH, Booth RE, et al: Cemented versus cementless total hip arthroplasty: a comparative study of equivalent patient populations. Clin Orthop 289:161, 1993
    • (1993) Clin Orthop , vol.289 , pp. 161
    • Hozack, W.J.1    Rothman, R.H.2    Booth, R.E.3
  • 2
    • 0025886244 scopus 로고
    • Total hip replacement with cemented, uncemented, and hybrid prostheses: A comparison of clinical and radiographic results at 2-4 years
    • Wixson RL, Stuhlberg SD, Mehlhoff M: Total hip replacement with cemented, uncemented, and hybrid prostheses: a comparison of clinical and radiographic results at 2-4 years. J Bone Joint Surg Am 73:257, 1991
    • (1991) J Bone Joint Surg Am , vol.73 , pp. 257
    • Wixson, R.L.1    Stuhlberg, S.D.2    Mehlhoff, M.3
  • 3
    • 0020524990 scopus 로고
    • Hip arthroplasty with a Moore prosthesis with porous-coating: A 5 year study
    • Engh CA: Hip arthroplasty with a Moore prosthesis with porous-coating: a 5 year study. Clin Orthop 176:52, 1983
    • (1983) Clin Orthop , vol.176 , pp. 52
    • Engh, C.A.1
  • 4
    • 0033384674 scopus 로고    scopus 로고
    • Clinical experience with a proximally porous-coated secondgeneration cementless total hip prosthesis: Minimum 5-year follow-up
    • Mont MA, Yoon TR, Krackow KA, et al: Clinical experience with a proximally porous-coated secondgeneration cementless total hip prosthesis: minimum 5-year follow-up. J Arthroplasty 14:930, 1999
    • (1999) J Arthroplasty , vol.14 , pp. 930
    • Mont, M.A.1    Yoon, T.R.2    Krackow, K.A.3
  • 5
    • 0031958062 scopus 로고    scopus 로고
    • Immediate weightbearing after uncemented total hip arthroplasty
    • Rao RR, Sharkey PF, Hozack WJ, et al: Immediate weightbearing after uncemented total hip arthroplasty. Clin Orthop 349:156, 1998
    • (1998) Clin Orthop , vol.349 , pp. 156
    • Rao, R.R.1    Sharkey, P.F.2    Hozack, W.J.3
  • 6
    • 0026475736 scopus 로고
    • Cementless total hip arthroplasty using a porous-coated prosthesis for bone ingrowth fixation: 3 1/2 Year follow-up
    • Woolson ST, Maloney WJ: Cementless total hip arthroplasty using a porous-coated prosthesis for bone ingrowth fixation: 3 1/2 Year follow-up. J Arthroplasty 7:381, 1992
    • (1992) J Arthroplasty , vol.7 , pp. 381
    • Woolson, S.T.1    Maloney, W.J.2
  • 7
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty: An end-result study using a new method of result evaluation
    • Harris WH: Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty: an end-result study using a new method of result evaluation. J Bone Joint Surg Am 51:737, 1969
    • (1969) J Bone Joint Surg Am , vol.51 , pp. 737
    • Harris, W.H.1
  • 8
    • 0023240947 scopus 로고
    • Porous-coated hip replacement: The factors governing bone ingrowth, stress shielding, and clinical results
    • Engh CA, Bobyn JD, Glassman AH: Porous-coated hip replacement: the factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br 69:45, 1987
    • (1987) J Bone Joint Surg Br , vol.69 , pp. 45
    • Engh, C.A.1    Bobyn, J.D.2    Glassman, A.H.3
  • 9
    • 0015754154 scopus 로고
    • Ectopic ossification following total hip replacement: Incidence and a method of classification
    • Brooker AF, Bowerman JW, Robinson RA, et al: Ectopic ossification following total hip replacement: incidence and a method of classification. J Bone Joint Surg Am 55:1629, 1973
    • (1973) J Bone Joint Surg Am , vol.55 , pp. 1629
    • Brooker, A.F.1    Bowerman, J.W.2    Robinson, R.A.3
  • 10
    • 0031725839 scopus 로고    scopus 로고
    • Total hip arthroplasty with porous-coated prostheses fixed without cement in patients who are sixty-five years of age or older
    • McAuley JP, Moore KD, Culpepper WJ, et al: Total hip arthroplasty with porous-coated prostheses fixed without cement in patients who are sixty-five years of age or older. J Bone Joint Surg Am 80:1648, 1998
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 1648
    • McAuley, J.P.1    Moore, K.D.2    Culpepper, W.J.3
  • 11
    • 1842297586 scopus 로고    scopus 로고
    • Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty
    • Engh CA Jr, Culpepper WJ, Engh CA: Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty. J Bone Joint Surg Am 79:177, 1997
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 177
    • Engh C.A., Jr.1    Culpepper, W.J.2    Engh, C.A.3
  • 12
    • 0031855324 scopus 로고    scopus 로고
    • Examination of wear in Duraloc acetabular components: Two- to five-year evaluation of Hylamer and Enduron liners
    • Sychterz CJ, Shah N, Engh CA, et al: Examination of wear in Duraloc acetabular components: two- to five-year evaluation of Hylamer and Enduron liners. J Arthroplasty 13:508, 1998
    • (1998) J Arthroplasty , vol.13 , pp. 508
    • Sychterz, C.J.1    Shah, N.2    Engh, C.A.3
  • 13
    • 0032831927 scopus 로고    scopus 로고
    • Early osteolysis following total hip arthroplasty with use of a Hylamer liner in combination with a modular ceramic femoral head: A case report
    • Vaughn BK, Dameron TB. Bauer T, et al: Early osteolysis following total hip arthroplasty with use of a Hylamer liner in combination with a modular ceramic femoral head: a case report. J Bone Joint Surg Am 81:1446, 1999
    • (1999) J Bone Joint Surg Am , vol.81 , pp. 1446
    • Vaughn, B.K.1    Dameron, T.B.2    Bauer, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.