메뉴 건너뛰기




Volumn 40, Issue 4, 2002, Pages 852-855

Coronary steal from a left internal mammary artery coronary bypass graft by a left upper extremity arteriovenous hemodialysis fistula

Author keywords

Access; Arteriovenous (AV) fistula; Coronary artery bypass graft (CABG); Coronary artery disease (CAD); End stage renal disease (ESRD); Hemodialysis (HD); Left internal mammary artery (LIMA); Steal

Indexed keywords

AGED; ANGINA PECTORIS; ARTERIOVENOUS FISTULA; ARTERY STEAL SYNDROME; ARTICLE; CARDIOVASCULAR DISEASE; CASE REPORT; CORONARY ARTERY BYPASS GRAFT; HEART CATHETERIZATION; HEART MUSCLE OXYGEN CONSUMPTION; HEART OUTPUT; HEMODIALYSIS; HUMAN; INTERNAL MAMMARY ARTERY; KIDNEY FAILURE; MALE; VASCULAR ACCESS;

EID: 0036789164     PISSN: 02726386     EISSN: None     Source Type: Journal    
DOI: 10.1053/ajkd.2002.35701     Document Type: Article
Times cited : (60)

References (7)
  • 1
    • 0014020729 scopus 로고
    • Chronic hemodialysis using venipuncture and a surgically created arteriovenous fistula
    • Brescia MJ, Cimino JE, Appel K, Hurwich BJ: Chronic hemodialysis using venipuncture and a surgically created arteriovenous fistula. N Engl J Med 275:1089-1092, 1966
    • (1966) N Engl J Med , vol.275 , pp. 1089-1092
    • Brescia, M.J.1    Cimino, J.E.2    Appel, K.3    Hurwich, B.J.4
  • 3
    • 0016593074 scopus 로고
    • Value of internal mammary artery bypasss
    • Barner HB: Value of internal mammary artery bypasss. Adv Cardiol 15:170-178, 1975
    • (1975) Adv Cardiol , vol.15 , pp. 170-178
    • Barner, H.B.1
  • 4
    • 0036146328 scopus 로고    scopus 로고
    • Is "steal" present in hemodialysis patients with ipsilateral internal mammary graft?
    • Baciewicz FA Jr, Harris RJ: Is "steal" present in hemodialysis patients with ipsilateral internal mammary graft? Ann Thorac Surg 73:349-350, 2002
    • (2002) Ann Thorac Surg , vol.73 , pp. 349-350
    • Baciewicz F.A., Jr.1    Harris, R.J.2
  • 6
    • 0028087874 scopus 로고
    • Banding a hemodialysis arteriovenous fistula to decrease blood flow and resolve high output cardiac failure: Report of a case
    • Isoda S, Kajiwara H, Kondo J, Matsumoto A: Banding a hemodialysis arteriovenous fistula to decrease blood flow and resolve high output cardiac failure: Report of a case. Surg Today 24:734-736, 1994
    • (1994) Surg Today , vol.24 , pp. 734-736
    • Isoda, S.1    Kajiwara, H.2    Kondo, J.3    Matsumoto, A.4
  • 7
    • 0023802884 scopus 로고
    • An evaluation of expanded PTFE loop grafts in the thigh as vascular access for hemodialysis in patients with access problems
    • Slater ND, Raftery AT: An evaluation of expanded PTFE loop grafts in the thigh as vascular access for hemodialysis in patients with access problems. Ann R Coll Surg Engl 70:243-245, 1988
    • (1988) Ann R Coll Surg Engl , vol.70 , pp. 243-245
    • Slater, N.D.1    Raftery, A.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.