메뉴 건너뛰기




Volumn 30, Issue 8, 2002, Pages 506-509

Detection of air microbubbles in the internal jugular vein after intravenous injection of contrast agent for the diagnosis of patent foramen ovale

Author keywords

Contrast agent; Internal jugular valve; Internal jugular vein; Transcranial Doppler ultrasonography; Ultrasonography

Indexed keywords

CONTRAST MEDIUM; SODIUM CHLORIDE;

EID: 0036787767     PISSN: 00912751     EISSN: None     Source Type: Journal    
DOI: 10.1002/jcu.10105     Document Type: Article
Times cited : (5)

References (14)
  • 1
    • 0023895824 scopus 로고
    • Prevalence of patent foramen ovale in patients with stroke
    • Lechat PH, Mas JL, Lascault G, et al. Prevalence of patent foramen ovale in patients with stroke. N Engl J Med 1988;318:1148.
    • (1988) N Engl J Med , vol.318 , pp. 1148
    • Lechat, P.H.1    Mas, J.L.2    Lascault, G.3
  • 2
    • 0023879994 scopus 로고
    • Patent foramen ovale in young stroke patients
    • Webster MWI, Smith HJ, Sharpe DN, et al. Patent foramen ovale in young stroke patients. Lancet 1988;2:11.
    • (1988) Lancet , vol.2 , pp. 11
    • Webster, M.W.I.1    Smith, H.J.2    Sharpe, D.N.3
  • 3
    • 0001735680 scopus 로고
    • Validation of transcranial Doppler sonography in the assessment of patent foramen ovale
    • Anzola GP, Renaldini E, Magoni M, et al. Validation of transcranial Doppler sonography in the assessment of patent foramen ovale. Cerebrovasc Dis 1995;5:194.
    • (1995) Cerebrovasc Dis , vol.5 , pp. 194
    • Anzola, G.P.1    Renaldini, E.2    Magoni, M.3
  • 4
    • 0028337578 scopus 로고
    • A comparison of transesophageal echocardiography and transcranial Doppler sonography with contrast medium for detection of patent foramen ovale
    • Jauss M, Kaps M, Keberle M, et al. A comparison of transesophageal echocardiography and transcranial Doppler sonography with contrast medium for detection of patent foramen ovale. Stroke 1994;25:1265.
    • (1994) Stroke , vol.25 , pp. 1265
    • Jauss, M.1    Kaps, M.2    Keberle, M.3
  • 5
    • 0030481612 scopus 로고    scopus 로고
    • Patent foramen ovale and transcranial Doppler: Comparison of different procedures
    • Zanette EM, Mancini G, De Castro S, et al. Patent foramen ovale and transcranial Doppler: comparison of different procedures. Stroke 1996;27:2251.
    • (1996) Stroke , vol.27 , pp. 2251
    • Zanette, E.M.1    Mancini, G.2    De Castro, S.3
  • 6
    • 0026058959 scopus 로고
    • Transesophageal echocardiographic demonstration of distinct mechanisms for right to left shunting across a patent foramen ovale in the absence of pulmonary hypertension
    • Langholz D, Louie EK, Konstadt SN, et al. Transesophageal echocardiographic demonstration of distinct mechanisms for right to left shunting across a patent foramen ovale in the absence of pulmonary hypertension. J Am Coll Cardiol 1991;18:1112.
    • (1991) J Am Coll Cardiol , vol.18 , pp. 1112
    • Langholz, D.1    Louie, E.K.2    Konstadt, S.N.3
  • 7
    • 0023626021 scopus 로고
    • Anatomic and pathophysiology studies of the human internal jugular valve
    • Dresser LP, McKinney WM. Anatomic and pathophysiology studies of the human internal jugular valve. Am J Surg 1987;154:220.
    • (1987) Am J Surg , vol.154 , pp. 220
    • Dresser, L.P.1    McKinney, W.M.2
  • 8
    • 0020059713 scopus 로고
    • Determinants and clinical significance of jugular venous valve competence
    • Fisher J, Vaghaiwalla F, Tsitlik J, et al. Determinants and clinical significance of jugular venous valve competence. Circulation 1982;65:188.
    • (1982) Circulation , vol.65 , pp. 188
    • Fisher, J.1    Vaghaiwalla, F.2    Tsitlik, J.3
  • 10
    • 0016915520 scopus 로고
    • Cervical venous reflux in dynamic brain scintigraphy
    • Hayt DB, Perez LA. Cervical venous reflux in dynamic brain scintigraphy. J Nucl Med 1976;17:9.
    • (1976) J Nucl Med , vol.17 , pp. 9
    • Hayt, D.B.1    Perez, L.A.2
  • 11
    • 0019962859 scopus 로고
    • Mechanisms by which positive end-expiratory pressure increases cerebrospinal fluid in dogs
    • Luce JM, Huseby JS, Kirk W, et al. Mechanisms by which positive end-expiratory pressure increases cerebrospinal fluid in dogs. J Appl Physiol 1982;52:231.
    • (1982) J Appl Physiol , vol.52 , pp. 231
    • Luce, J.M.1    Huseby, J.S.2    Kirk, W.3
  • 12
    • 0034627267 scopus 로고    scopus 로고
    • Disturbance of venous flow patterns in patients with transient global amnesia
    • Sander D, Winbek K, Etgen T, et al. Disturbance of venous flow patterns in patients with transient global amnesia. Lancet 2000;356:1982.
    • (2000) Lancet , vol.356 , pp. 1982
    • Sander, D.1    Winbek, K.2    Etgen, T.3
  • 13
    • 0021961767 scopus 로고
    • Ultrasonic evaluation of jugular venous valve competence
    • Brownlow RL, McKinney WM. Ultrasonic evaluation of jugular venous valve competence. J Ultrasound Med 1985;4:169.
    • (1985) J Ultrasound Med , vol.4 , pp. 169
    • Brownlow, R.L.1    McKinney, W.M.2
  • 14
    • 0010639272 scopus 로고    scopus 로고
    • Prevalence of jugular reflux with color flow imaging
    • Alayon A, McKinney WM, Tegeler CH, et al. Prevalence of jugular reflux with color flow imaging [abstract]. J Neuroimaging 1997;7:246.
    • (1997) J Neuroimaging , vol.7 , pp. 246
    • Alayon, A.1    McKinney, W.M.2    Tegeler, C.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.