Volumn 37, Issue 10, 2002, Pages 1483-1484

Bronchial complication of a closed-tube endotracheal suction catheter

Author keywords

Bronchoscopy; Endotracheal suction catheter; Pneumothorax

Indexed keywords

ARTICLE; BRONCHOSCOPY; CASE REPORT; CATHETER; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; FOREIGN BODY; HUMAN; NEWBORN; PNEUMOTHORAX; PREMATURITY; PRIORITY JOURNAL; THORAX RADIOGRAPHY; TRACHEOBRONCHIAL TOILET; TUBE; BRONCHUS; CATHETERIZATION; ENDOTRACHEAL INTUBATION; INSTRUMENTATION; SUCTION;

EID: 0036787224     PISSN: 00223468     EISSN: None     Source Type: Journal    
DOI: 10.1053/jpsu.2002.35422     Document Type: Article
Times cited : (12)

References (12)
  • 1
    • 0022814488 scopus 로고
    • Contamination of a multiuse suction catheter in closed-circuit system compared to contamination of a disposible, single-use suction catheter
    • Ritz R, Scott LR, Coyle MB, et al: Contamination of a multiuse suction catheter in closed-circuit system compared to contamination of a disposible, single-use suction catheter. Resp Care 31:1086-1091, 1986.
    • (1986) Resp Care , vol.31 , pp. 1086-1091
    • Ritz, R.1    Scott, L.R.2    Coyle, M.B.3
  • 2
    • 0033844370 scopus 로고    scopus 로고
    • Bronchial perforation after closed-tube endotracheal suction
    • Thakur A, Buchmiller T, Atkinson J: Bronchial perforation after closed-tube endotracheal suction. J Pediatr Surg 35:1353-55, 2000
    • (2000) J Pediatr Surg , vol.35 , pp. 1353-1355
    • Thakur, A.1    Buchmiller, T.2    Atkinson, J.3
  • 3
    • 0024998773 scopus 로고
    • Effect of endotracheal suctioning on arterial blood gases in children
    • Kerem E, Yatsiv I, Goitein KJ: Effect of endotracheal suctioning on arterial blood gases in children. Int Care Med 16:95-99, 1990
    • (1990) Int Care Med , vol.16 , pp. 95-99
    • Kerem, E.1    Yatsiv, I.2    Goitein, K.J.3
  • 4
    • 0028293191 scopus 로고
    • Closed versus open endotracheal suctioning: Costs and physiologic consequences
    • Johnson KI, Kearney PA, Johnson SB, et al: Closed versus open endotracheal suctioning: Costs and physiologic consequences. Crit Care Med 22:658-666, 1994
    • (1994) Crit Care Med , vol.22 , pp. 658-666
    • Johnson, K.I.1    Kearney, P.A.2    Johnson, S.B.3
  • 5
    • 0026602921 scopus 로고
    • Fluctuations in cerebral oxygenation and blood volume during endotracheal suctioning in premature infants
    • Shah AR, Kurth CD, Gwiazdowski SG, et al: Fluctuations in cerebral oxygenation and blood volume during endotracheal suctioning in premature infants. J Pediatr 120:769-74, 1992
    • (1992) J Pediatr , vol.120 , pp. 769-774
    • Shah, A.R.1    Kurth, C.D.2    Gwiazdowski, S.G.3
  • 6
    • 0018873401 scopus 로고
    • Transient bacteraemia following endotracheal suctioning in ventilated newborns
    • Storm W: Transient bacteraemia following endotracheal suctioning in ventilated newborns. Pediatrics 65:487-490, 1980
    • (1980) Pediatrics , vol.65 , pp. 487-490
    • Storm, W.1
  • 7
    • 0025647269 scopus 로고    scopus 로고
    • Incidence of colonization, nosocomial pneumonia, and mortality in critically ill patients using a Trach Care™ closed-suction system versus an open-suction system: Prospective, randomised study
    • Deppe SA, Kelly W, Thoi LL, et al: Incidence of colonization, nosocomial pneumonia, and mortality in critically ill patients using a Trach Care™ closed-suction system versus an open-suction system: Prospective, randomised study. Crit Care Med 12:1389-1393
    • Crit Care Med , vol.12 , pp. 1389-1393
    • Deppe, S.A.1    Kelly, W.2    Thoi, L.L.3
  • 8
    • 0034167158 scopus 로고    scopus 로고
    • Comparison of a closed (Trach Care MAC) with an open endotracheal suction system in small premature infants
    • Cordero L, Sananes M, Ayers LW: Comparison of a closed (Trach Care MAC) with an open endotracheal suction system in small premature infants. J Perinatol 3:151-156, 2000
    • (2000) J Perinatol , vol.3 , pp. 151-156
    • Cordero, L.1    Sananes, M.2    Ayers, L.W.3
  • 9
    • 0017033725 scopus 로고
    • Pneumothorax secondary to perforation of sequential bronchi by suction catheters
    • Anderson MD, Chandra R: Pneumothorax secondary to perforation of sequential bronchi by suction catheters. J Pediatr Surg 11:687-693, 1976
    • (1976) J Pediatr Surg , vol.11 , pp. 687-693
    • Anderson, M.D.1    Chandra, R.2
  • 10
    • 0019493974 scopus 로고
    • Successful surgical repair of iatrogenic lung perforation in a neonate
    • Gangitano ES, Pomerance JJ, Gans SL: Successful surgical repair of iatrogenic lung perforation in a neonate. J Pediatr Surg 16:70-71, 1981
    • (1981) J Pediatr Surg , vol.16 , pp. 70-71
    • Gangitano, E.S.1    Pomerance, J.J.2    Gans, S.L.3
  • 11
    • 0024441937 scopus 로고
    • Iatrogenic perforation of the bronchus intermedius in a 1,100-g neonate
    • Holcomb GW III, Templeton JM Jr: Iatrogenic perforation of the bronchus intermedius in a 1,100-g neonate. J Pediatr Surg 24:1132-1134, 1989
    • (1989) J Pediatr Surg , vol.24 , pp. 1132-1134
    • Holcomb G.W. III1    Templeton J.M., Jr.2
  • 12
    • 0027525389 scopus 로고
    • Prognostic implications of age at detection of air leak in very low weight infants requiring ventilation support
    • Powers WF, Clemens JD: Prognostic implications of age at detection of air leak in very low weight infants requiring ventilation support. J Pediatr 123:611-617, 1993
    • (1993) J Pediatr , vol.123 , pp. 611-617
    • Powers, W.F.1    Clemens, J.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.