메뉴 건너뛰기




Volumn 46, Issue 9, 2002, Pages 1179-

No correlation between serum concentrations of S100B and cognitive function [5]

Author keywords

[No Author keywords available]

Indexed keywords

PROTEIN S100B;

EID: 0036786224     PISSN: 00015172     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1399-6576.2002.460922_7.x     Document Type: Letter
Times cited : (4)

References (6)
  • 1
    • 0036185998 scopus 로고    scopus 로고
    • Changes in serum S100 beta protein and Mini-Mental State Examination after cold and warm cardiopulmonary bypass using different blood gas strategies
    • Shaaban-Ali M, Harmer M, Vaughan RS, Dunne JA, Latto IP, Haaverstad R et al. Changes in serum S100 beta protein and Mini-Mental State Examination after cold and warm cardiopulmonary bypass using different blood gas strategies. Acta Anaesth Scand 2002: 46: 10-16.
    • (2002) Acta Anaesth Scand , vol.46 , pp. 10-16
    • Shaaban-Ali, M.1    Harmer, M.2    Vaughan, R.S.3    Dunne, J.A.4    Latto, I.P.5    Haaverstad, R.6
  • 2
    • 0036235125 scopus 로고    scopus 로고
    • Serum concentration of S-100 protein in assessment of cognitive dysfunction after general anesthesia in different types of surgery
    • Linstedt U, Meyer O, Kropp P, Berkau A, Tapp E, Zenz M. Serum concentration of S-100 protein in assessment of cognitive dysfunction after general anesthesia in different types of surgery. Acta Anaesth Scand 2002: 46: 384-389.
    • (2002) Acta Anaesth Scand , vol.46 , pp. 384-389
    • Linstedt, U.1    Meyer, O.2    Kropp, P.3    Berkau, A.4    Tapp, E.5    Zenz, M.6
  • 3
    • 0033233110 scopus 로고    scopus 로고
    • S100β after coronary surgery. Release pattern, source of contamination, and relation to neuropsychological outcome
    • Jönsson H, Johnsson P, Alling C, Bäckström M, Bergh C, Blomquist S. S100β after coronary surgery. Release pattern, source of contamination, and relation to neuropsychological outcome. Ann Thorac Surg 1999: 68: 2202-2208.
    • (1999) Ann Thorac Surg , vol.68 , pp. 2202-2208
    • Jönsson, H.1    Johnsson, P.2    Alling, C.3    Bäckström, M.4    Bergh, C.5    Blomquist, S.6
  • 4
    • 0034031859 scopus 로고    scopus 로고
    • The effect of the cardiotomy suction on the brain injury marker S100β after cardiopulmonary bypass
    • Anderson R, Hansson L-O, Liska J, Settergren G, Vaage J. The effect of the cardiotomy suction on the brain injury marker S100β after cardiopulmonary bypass. Ann Thorac Surg 2000: 69: 847-850.
    • (2000) Ann Thorac Surg , vol.69 , pp. 847-850
    • Anderson, R.1    Hansson, L.-O.2    Liska, J.3    Settergren, G.4    Vaage, J.5
  • 5
    • 0034998431 scopus 로고    scopus 로고
    • High serum S100B levels for trauma patients without head injuries
    • discussion 1258-1260; letters 49: 1272-1273, and 1490-1493
    • Anderson R, Hansson L-O, Dijlai-Merzoug R, Settergren G. High serum S100B levels for trauma patients without head injuries. Neurosurgery 2001: 48: 1255-1258, discussion 1258-1260; letters 49: 1272-1273, and 1490-1493.
    • (2001) Neurosurgery , vol.48 , pp. 1255-1258
    • Anderson, R.1    Hansson, L.-O.2    Dijlai-Merzoug, R.3    Settergren, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.