-
1
-
-
0029612812
-
Thin-section three-dimensional spiral CT: Is isotropic imaging possible?
-
Kalender WA. Thin-section three-dimensional spiral CT: is isotropic imaging possible? Radiology 1995:197:578-580
-
(1995)
Radiology
, vol.197
, pp. 578-580
-
-
Kalender, W.A.1
-
2
-
-
0028912092
-
Reconstructed helical CT scans: Improvement in z-axis resolution compared with overlapped and nonoverlapped conventional CT scans
-
Kasales CJ, Hopper KD, Ariola DN, et al. Reconstructed helical CT scans: improvement in z-axis resolution compared with overlapped and nonoverlapped conventional CT scans. AJR 1995;164:1281-1284
-
(1995)
AJR
, vol.164
, pp. 1281-1284
-
-
Kasales, C.J.1
Hopper, K.D.2
Ariola, D.N.3
-
3
-
-
0028230441
-
Stair-step artifacts in three-dimensional helical CT: An experimental study
-
Wang G, Vannier MW. Stair-step artifacts in three-dimensional helical CT: an experimental study. Radiology 1994;191:79-83
-
(1994)
Radiology
, vol.191
, pp. 79-83
-
-
Wang, G.1
Vannier, M.W.2
-
4
-
-
0032924568
-
Multi-slice helical CT: Scan and reconstruction
-
Hu H. Multi-slice helical CT: scan and reconstruction. Med Phys 1999;26:5-18
-
(1999)
Med Phys
, vol.26
, pp. 5-18
-
-
Hu, H.1
-
5
-
-
0033919451
-
Stair-step artifacts with single versus multiple detector-row helical CT
-
Fleischmann D, Rubin GD, Paik DS. Stair-step artifacts with single versus multiple detector-row helical CT. Radiology 2000;216:185-196
-
(2000)
Radiology
, vol.216
, pp. 185-196
-
-
Fleischmann, D.1
Rubin, G.D.2
Paik, D.S.3
-
7
-
-
0029122209
-
Technical aspects of helical (spiral) CT
-
Brink JA. Technical aspects of helical (spiral) CT Radiol Clin North Am 1995;33:825-841
-
(1995)
Radiol Clin North Am
, vol.33
, pp. 825-841
-
-
Brink, J.A.1
-
8
-
-
0033016205
-
Temporal bone: Comparison of isotropic helical CT and conventional direct axial and coronal CT
-
Caldemeyer KS, Sandrasegaran K, Shinaver CN, Mathews VP, Smith RR, Kopecky KK. Temporal bone: comparison of isotropic helical CT and conventional direct axial and coronal CT. AJR 1999;172:1675-1682
-
(1999)
AJR
, vol.172
, pp. 1675-1682
-
-
Caldemeyer, K.S.1
Sandrasegaran, K.2
Shinaver, C.N.3
Mathews, V.P.4
Smith, R.R.5
Kopecky, K.K.6
-
9
-
-
0032712877
-
Petrosal bone: Coronal reconstructions from axial spiral CT data obtained with 0.5-mm collimation can replace direct coronal sequential CT scans
-
Venema HW, Phoa SS, Mirck PG, Hulsmans FJ, Majoie CB, Verbeeten B Jr. Petrosal bone: coronal reconstructions from axial spiral CT data obtained with 0.5-mm collimation can replace direct coronal sequential CT scans. Radiology 1999;213:375-382
-
(1999)
Radiology
, vol.213
, pp. 375-382
-
-
Venema, H.W.1
Phoa, S.S.2
Mirck, P.G.3
Hulsmans, F.J.4
Majoie, C.B.5
Verbeeten B., Jr.6
-
10
-
-
0034829189
-
High-resolution CT using multidetector CT equipment: Evaluation of image quality in 11 cadaveric lungs and a phantom
-
Honda O, Johkoh T, Tomiyama N, et al. High-resolution CT using multidetector CT equipment: evaluation of image quality in 11 cadaveric lungs and a phantom. AJR 2001;177:875-879
-
(2001)
AJR
, vol.177
, pp. 875-879
-
-
Honda, O.1
Johkoh, T.2
Tomiyama, N.3
|