메뉴 건너뛰기




Volumn 179, Issue 4, 2002, Pages 875-879

Comparison of quality of multiplanar reconstructions and direct coronal multidetector CT scans of the lung

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHM; ARTICLE; ARTIFACT; AUTOPSY; COLLIMATOR; COMPARATIVE STUDY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; HUMAN; HUMAN TISSUE; IMAGE QUALITY; IMAGE RECONSTRUCTION; LUNG; NORMAL HUMAN; PRIORITY JOURNAL;

EID: 0036783772     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/ajr.179.4.1790875     Document Type: Article
Times cited : (53)

References (10)
  • 1
    • 0029612812 scopus 로고
    • Thin-section three-dimensional spiral CT: Is isotropic imaging possible?
    • Kalender WA. Thin-section three-dimensional spiral CT: is isotropic imaging possible? Radiology 1995:197:578-580
    • (1995) Radiology , vol.197 , pp. 578-580
    • Kalender, W.A.1
  • 2
    • 0028912092 scopus 로고
    • Reconstructed helical CT scans: Improvement in z-axis resolution compared with overlapped and nonoverlapped conventional CT scans
    • Kasales CJ, Hopper KD, Ariola DN, et al. Reconstructed helical CT scans: improvement in z-axis resolution compared with overlapped and nonoverlapped conventional CT scans. AJR 1995;164:1281-1284
    • (1995) AJR , vol.164 , pp. 1281-1284
    • Kasales, C.J.1    Hopper, K.D.2    Ariola, D.N.3
  • 3
    • 0028230441 scopus 로고
    • Stair-step artifacts in three-dimensional helical CT: An experimental study
    • Wang G, Vannier MW. Stair-step artifacts in three-dimensional helical CT: an experimental study. Radiology 1994;191:79-83
    • (1994) Radiology , vol.191 , pp. 79-83
    • Wang, G.1    Vannier, M.W.2
  • 4
    • 0032924568 scopus 로고    scopus 로고
    • Multi-slice helical CT: Scan and reconstruction
    • Hu H. Multi-slice helical CT: scan and reconstruction. Med Phys 1999;26:5-18
    • (1999) Med Phys , vol.26 , pp. 5-18
    • Hu, H.1
  • 5
    • 0033919451 scopus 로고    scopus 로고
    • Stair-step artifacts with single versus multiple detector-row helical CT
    • Fleischmann D, Rubin GD, Paik DS. Stair-step artifacts with single versus multiple detector-row helical CT. Radiology 2000;216:185-196
    • (2000) Radiology , vol.216 , pp. 185-196
    • Fleischmann, D.1    Rubin, G.D.2    Paik, D.S.3
  • 7
    • 0029122209 scopus 로고
    • Technical aspects of helical (spiral) CT
    • Brink JA. Technical aspects of helical (spiral) CT Radiol Clin North Am 1995;33:825-841
    • (1995) Radiol Clin North Am , vol.33 , pp. 825-841
    • Brink, J.A.1
  • 9
    • 0032712877 scopus 로고    scopus 로고
    • Petrosal bone: Coronal reconstructions from axial spiral CT data obtained with 0.5-mm collimation can replace direct coronal sequential CT scans
    • Venema HW, Phoa SS, Mirck PG, Hulsmans FJ, Majoie CB, Verbeeten B Jr. Petrosal bone: coronal reconstructions from axial spiral CT data obtained with 0.5-mm collimation can replace direct coronal sequential CT scans. Radiology 1999;213:375-382
    • (1999) Radiology , vol.213 , pp. 375-382
    • Venema, H.W.1    Phoa, S.S.2    Mirck, P.G.3    Hulsmans, F.J.4    Majoie, C.B.5    Verbeeten B., Jr.6
  • 10
    • 0034829189 scopus 로고    scopus 로고
    • High-resolution CT using multidetector CT equipment: Evaluation of image quality in 11 cadaveric lungs and a phantom
    • Honda O, Johkoh T, Tomiyama N, et al. High-resolution CT using multidetector CT equipment: evaluation of image quality in 11 cadaveric lungs and a phantom. AJR 2001;177:875-879
    • (2001) AJR , vol.177 , pp. 875-879
    • Honda, O.1    Johkoh, T.2    Tomiyama, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.