메뉴 건너뛰기




Volumn 35, Issue 5, 2002, Pages 381-391

Dose measurements in space by the Hungarian Pille TLD system

Author keywords

[No Author keywords available]

Indexed keywords

COSMIC RAYS; EARTH (PLANET); ENERGY UTILIZATION; PROBLEM SOLVING;

EID: 0036772002     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1350-4487(02)00071-9     Document Type: Article
Times cited : (24)

References (11)
  • 2
    • 0030326490 scopus 로고    scopus 로고
    • Microprocessor controlled portable TLD system
    • Apáthy I., Deme S., Fehér I. Microprocessor controlled portable TLD system. Radiat. Prot. Dosim. 66:1996;441-444.
    • (1996) Radiat. Prot. Dosim. , vol.66 , pp. 441-444
    • Apáthy, I.1    Deme, S.2    Fehér, I.3
  • 4
    • 0036772032 scopus 로고    scopus 로고
    • Passive dosimetry abroad the Mir Orbital Station: Part I - Internal measurements
    • X ref: S1350-4487(02)00075-6
    • Benton, E.R., Benton, E.V., Frank, A.L., 2002. Passive dosimetry abroad the Mir Orbital Station: Part I - Internal measurements. Radiat. Meas. X ref: S1350-4487(02)00075-6.
    • (2002) Radiat. Meas.
    • Benton, E.R.1    Benton, E.V.2    Frank, A.L.3
  • 5
    • 0032767564 scopus 로고    scopus 로고
    • Doses due to the South Atlantic anomaly during the Euromir'95 Mission measured by an on-board TLD system
    • Deme S., Reitz G., Apáthy I., Héjja I., Láng E., Fehér I. Doses due to the South Atlantic anomaly during the Euromir'95 Mission measured by an on-board TLD system. Radiat. Prot. Dosim. 85:1999;301-304.
    • (1999) Radiat. Prot. Dosim. , vol.85 , pp. 301-304
    • Deme, S.1    Reitz, G.2    Apáthy, I.3    Héjja, I.4    Láng, E.5    Fehér, I.6
  • 6
    • 0032809879 scopus 로고    scopus 로고
    • Extra dose due to EVA during the NASA4 mission measured by an on-board TLD system
    • Deme S., Apáthy I., Héjja I., Láng E., Fehér I. Extra dose due to EVA during the NASA4 mission measured by an on-board TLD system. Radiat. Prot. Dosim. 85:1999;121-124.
    • (1999) Radiat. Prot. Dosim. , vol.85 , pp. 121-124
    • Deme, S.1    Apáthy, I.2    Héjja, I.3    Láng, E.4    Fehér, I.5
  • 11
    • 0032810136 scopus 로고    scopus 로고
    • The LET dependence of LiF:Mg,Ti dosemeters and its application for LET measurements in mixed radiation fields
    • Schöner W., Vana N., Fugger M. The LET dependence of LiF:Mg,Ti dosemeters and its application for LET measurements in mixed radiation fields. Radiat. Prot. Dosim. 85:1999;263-266.
    • (1999) Radiat. Prot. Dosim. , vol.85 , pp. 263-266
    • Schöner, W.1    Vana, N.2    Fugger, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.