메뉴 건너뛰기




Volumn 47, Issue 3, 2002, Pages 179-180

A new source of allergic contact dermatitis from UV-cured (meth)acrylate adhesive

Author keywords

(Meth)acrylates occupational; Adhesive allergic contact dermatitis; UV cured

Indexed keywords

2 HYDROXYETHYL METHACRYLATE; 2 PROPANOL; GLASS; GLUE; LATEX; METHACRYLIC ACID; SOLVENT;

EID: 0036765741     PISSN: 01051873     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1600-0536.2002.47030815.x     Document Type: Article
Times cited : (15)

References (10)
  • 1
    • 0022471816 scopus 로고
    • Contact dermatitis in printing tradesmen
    • Nethercott J R, Nosal R. Contact dermatitis in printing tradesmen. Contact Dermatitis 1986: 14: 280-228.
    • (1986) Contact Dermatitis , vol.14 , pp. 280-228
    • Nethercott, J.R.1    Nosal, R.2
  • 2
    • 0027475563 scopus 로고
    • Allergic contact dermatitis due to an amino-substituted diacrylate in a UV-cured lacquer
    • Carmichael A J, Foulds I S. Allergic contact dermatitis due to an amino-substituted diacrylate in a UV-cured lacquer. Contact Dermatitis 1993: 28: 45-46.
    • (1993) Contact Dermatitis , vol.28 , pp. 45-46
    • Carmichael, A.J.1    Foulds, I.S.2
  • 3
    • 0024502652 scopus 로고
    • Allergic contact dermatitis from dental composite resins due to aromatic epoxy acrylates and aliphatic acrylates
    • Kanerva L, Estlander T, Jolanki R. Allergic contact dermatitis from dental composite resins due to aromatic epoxy acrylates and aliphatic acrylates. Contact Dermatitis 1989: 20: 201-211.
    • (1989) Contact Dermatitis , vol.20 , pp. 201-211
    • Kanerva, L.1    Estlander, T.2    Jolanki, R.3
  • 4
    • 0027264585 scopus 로고
    • Allergy caused by light-cured ear moulds
    • Koefoed-Nielsen B, Pedersen B. Allergy caused by light-cured ear moulds. Scand Audiol 1993: 22: 193-194.
    • (1993) Scand Audiol , vol.22 , pp. 193-194
    • Koefoed-Nielsen, B.1    Pedersen, B.2
  • 5
    • 0025302314 scopus 로고
    • Adverse nail reactions and paraesthesia from "photobonded acrylate 'sculptured' nails"
    • Fisher A A. Adverse nail reactions and paraesthesia from "photobonded acrylate 'sculptured' nails". Cutis 1990: 45: 293-294.
    • (1990) Cutis , vol.45 , pp. 293-294
    • Fisher, A.A.1
  • 6
    • 0015230085 scopus 로고
    • Contact dermatitis from penetration of rubber gloves by acrylic monomer
    • Pegum J S, Medhurst F A. Contact dermatitis from penetration of rubber gloves by acrylic monomer. Br Med J 1971: 2: 141-143.
    • (1971) Br Med J , vol.2 , pp. 141-143
    • Pegum, J.S.1    Medhurst, F.A.2
  • 7
    • 0018673349 scopus 로고
    • Penetration of protective gloves by epoxy resin
    • Pegum J S. Penetration of protective gloves by epoxy resin. Contact Dermatitis 1979: 5: 281-283.
    • (1979) Contact Dermatitis , vol.5 , pp. 281-283
    • Pegum, J.S.1
  • 8
    • 0032935744 scopus 로고    scopus 로고
    • A 15-year study of patch testing to (meth) acrylates
    • Tucker S C, Beck Mh. A 15-year study of patch testing to (meth) acrylates. Contact Dermatitis 1999: 40: 278-279.
    • (1999) Contact Dermatitis , vol.40 , pp. 278-279
    • Tucker, S.C.1    Beck, M.2
  • 9
    • 0031443053 scopus 로고    scopus 로고
    • 10 years of patch testing with the (meth) acrylate series
    • Kanerva L, Jolanki R, Estlander T. 10 years of patch testing with the (meth) acrylate series. Contact Dermatitis 1997: 37: 255-258.
    • (1997) Contact Dermatitis , vol.37 , pp. 255-258
    • Kanerva, L.1    Jolanki, R.2    Estlander, T.3
  • 10
    • 0030898588 scopus 로고    scopus 로고
    • Product analysis of acrylic resins compared to information given in material safety data sheets
    • Henriks-Eckerman M-L, Kanerva L. Product analysis of acrylic resins compared to information given in material safety data sheets. Contact Dermatitis 1997: 36: 164-165.
    • (1997) Contact Dermatitis , vol.36 , pp. 164-165
    • Henriks-Eckerman, M.-L.1    Kanerva, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.