메뉴 건너뛰기




Volumn 38, Issue 5 I, 2002, Pages 3365-3367

A biochip based on magnetoresistive sensors

Author keywords

Biomagnetics; Biomedical measurements; Magnetoresistive devices; Sensors

Indexed keywords

DATA REDUCTION; DNA; SENSORS; SURFACE PHENOMENA;

EID: 0036762530     PISSN: 00189464     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMAG.2002.802290     Document Type: Article
Times cited : (83)

References (8)
  • 1
    • 33750860386 scopus 로고
    • Giant magnetoresistance of (001)Fe/(001)Cr magnetic superlattices
    • M.N. Baibich, J.M. Broto, A. Fert, F.N. Van Dau, and F. Petroff et al., "Giant magnetoresistance of (001)Fe/(001)Cr magnetic superlattices," Phys. Rev. Lett., vol 61, pp. 2472-2475, 1988.
    • (1988) Phys. Rev. Lett. , vol.61 , pp. 2472-2475
    • Baibich, M.N.1    Broto, J.M.2    Fert, A.3    Van Dau, F.N.4    Petroff, F.5
  • 2
    • 11944262717 scopus 로고
    • Large magnetoresistance at room temperature in ferromagnetic thin film tunnel junctions
    • J.S. Moodera, L.R. Kinder, T.M. Wong, and R. Meservey, "Large magnetoresistance at room temperature in ferromagnetic thin film tunnel junctions," Phys. Rev. Lett., vol. 4, pp. 3273-3276, 1995.
    • (1995) Phys. Rev. Lett. , vol.4 , pp. 3273-3276
    • Moodera, J.S.1    Kinder, L.R.2    Wong, T.M.3    Meservey, R.4
  • 4
  • 5
    • 0034227805 scopus 로고    scopus 로고
    • Model for detection of immobilized superparamagnetic nanosphere assay labels using giant magnetoresistive sensors
    • M. Tondra, M. Porter, and R.J. Lipert, "Model for detection of immobilized superparamagnetic nanosphere assay labels using giant magnetoresistive sensors," J. Vac. Sci. Technol. A, Vac. Surf. Films, vol. 18, no. 4, pp. 1125-1129, 2000.
    • (2000) J. Vac. Sci. Technol. A, Vac. Surf. Films , vol.18 , Issue.4 , pp. 1125-1129
    • Tondra, M.1    Porter, M.2    Lipert, R.J.3
  • 6
    • 0037094859 scopus 로고    scopus 로고
    • Single magnetic microsphere placement and detection on-chip using current line design with integrated spin valve sensors: Biotechnical applications
    • to be published
    • D.L. Graham, H. Ferreira, J. Bernardo, P.P. Freitas, and J.M.S. Cabral, "Single magnetic microsphere placement and detection on-chip using current line design with integrated spin valve sensors: Biotechnical applications," J. Appl. Phys., to be published.
    • J. Appl. Phys.
    • Graham, D.L.1    Ferreira, H.2    Bernardo, J.3    Freitas, P.P.4    Cabral, J.M.S.5
  • 7
    • 0011963859 scopus 로고    scopus 로고
    • Products CM01N/4620 and CM01N/5062. Bangs Laboratories, Inc., Fishers, IN. Online
    • Products CM01N/4620 and CM01N/5062. Bangs Laboratories, Inc., Fishers, IN. [Online]. Available: http://www.bangslabs.com.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.