메뉴 건너뛰기




Volumn 36, Issue 5, 2002, Pages 385-387

Technique for retrieval of a guidewire lodged in a vena cava filter

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; CASE REPORT; CENTRAL VENOUS CATHETERIZATION; CLINICAL FEATURE; DEEP VEIN THROMBOSIS; FLUOROSCOPY; GUIDE WIRE; HUMAN; JUGULAR VEIN; MALE; SURGICAL TECHNIQUE; VENA CAVA FILTER;

EID: 0036752296     PISSN: 15385744     EISSN: None     Source Type: Journal    
DOI: 10.1177/153857440203600509     Document Type: Article
Times cited : (4)

References (6)
  • 1
    • 0027689776 scopus 로고
    • Percutaneous retrieval of foreign bodies: Experience with the nitinol goose neck snare
    • Cekirge S, Weiss JP, Foster RG, et al: Percutaneous retrieval of foreign bodies: Experience with the nitinol goose neck snare. J Vasc Intervent Radiol 4:805-810, 1993.
    • (1993) J Vasc Intervent Radiol , vol.4 , pp. 805-810
    • Cekirge, S.1    Weiss, J.P.2    Foster, R.G.3
  • 2
    • 0026905794 scopus 로고
    • Retrieval of intravascular foreign bodies with the snare and catheter capture technique
    • Park JH, Yoon DY, Han HY, et al: Retrieval of intravascular foreign bodies with the snare and catheter capture technique. J Vasc Intervent Radiol 3:581-582, 1992.
    • (1992) J Vasc Intervent Radiol , vol.3 , pp. 581-582
    • Park, J.H.1    Yoon, D.Y.2    Han, H.Y.3
  • 3
    • 0026691034 scopus 로고
    • Wallstent misplaced during transjugular placement of an intrahepatic portosystemic shunt: Retrieval with a loop snare
    • Sanchez RB, Roberts AC, Valji K, et al: Wallstent misplaced during transjugular placement of an intrahepatic portosystemic shunt: Retrieval with a loop snare. AJR 159:129-130, 1992.
    • (1992) AJR , vol.159 , pp. 129-130
    • Sanchez, R.B.1    Roberts, A.C.2    Valji, K.3
  • 4
    • 0026071057 scopus 로고
    • Nitinol gooseneck snare for removal of foreign bodies: Experimental study and clinical evaluation
    • Yedlicka JW Jr, Carlson JE, Hunter DW, et al: Nitinol gooseneck snare for removal of foreign bodies: Experimental study and clinical evaluation. Radiology 178:691-693, 1991.
    • (1991) Radiology , vol.178 , pp. 691-693
    • Yedlicka, J.W.1    Carlson, J.E.2    Hunter, D.W.3
  • 5
    • 0033795721 scopus 로고    scopus 로고
    • Monorail technique for removal of entrapped exchange wire in a greenfield filter - Revisited
    • Morgan JT: Monorail technique for removal of entrapped exchange wire in a greenfield filter - revisited. J Vasc Intervent Radiol 11:1098-1099, 2000.
    • (2000) J Vasc Intervent Radiol , vol.11 , pp. 1098-1099
    • Morgan, J.T.1
  • 6
    • 0344447081 scopus 로고    scopus 로고
    • Monorail technique for removal of entrapped exchange wire in a Greenfield filter
    • Morgan JT, Sussman SK: Monorail technique for removal of entrapped exchange wire in a Greenfield filter. J Vasc Intervent Radiol 9:469-470, 1998.
    • (1998) J Vasc Intervent Radiol , vol.9 , pp. 469-470
    • Morgan, J.T.1    Sussman, S.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.