Volumn 5, Issue 3, 2002, Pages 313-318

Comparison of two hologic DXA systems (QDR 1000 and QDR 4500/A) for in vivo bone mass measurement in the baboon (Papio ursinus)

Author keywords

Bone densitometry; Bone mass; DXA system; Primates; Systemic bone loss

Indexed keywords

ANIMAL EXPERIMENT; ARTICLE; BABOON; BONE DENSITY; BONE MASS; BONE MINERAL; CALIBRATION; CONTROLLED STUDY; CORRELATION COEFFICIENT; DUAL ENERGY X RAY ABSORPTIOMETRY; FEMALE; IN VIVO STUDY; INTERMETHOD COMPARISON; LONGITUDINAL STUDY; LUMBAR SPINE; NONHUMAN; OVARIECTOMY; PHANTOM; PRIORITY JOURNAL; REGRESSION ANALYSIS;

EID: 0036750485     PISSN: 10946950     EISSN: None     Source Type: Journal    
DOI: 10.1385/JCD:5:3:313     Document Type: Article
Times cited : (6)

References (14)
  • 1
    • 9344263428 scopus 로고    scopus 로고
    • Noninvasive assessment of bone mineral and structure: State of the art
    • Genant HK, Engelke K, Fuerst T, et al. 1996 Noninvasive assessment of bone mineral and structure: state of the art. J Bone Miner Res 11:707-730.
    • (1996) J Bone Miner Res , vol.11 , pp. 707-730
    • Genant, H.K.1    Engelke, K.2    Fuerst, T.3
  • 2
    • 0026675710 scopus 로고
    • Assessment of spinal and femoral bone density by dual x-ray absorptiometry: Comparison of Lunar and Hologic instruments
    • Pocock NA, Sambrook PN, Nguyen T, Kelly P, Freund J, Eisman JA. 1992 Assessment of spinal and femoral bone density by dual x-ray absorptiometry: comparison of Lunar and Hologic instruments. J Bone Miner Res 7:1081-1084.
    • (1992) J Bone Miner Res , vol.7 , pp. 1081-1084
    • Pocock, N.A.1    Sambrook, P.N.2    Nguyen, T.3    Kelly, P.4    Freund, J.5    Eisman, J.A.6
  • 3
    • 0027532266 scopus 로고
    • Cross-calibration of DXA equipment: Upgrading from Hologic QDR 1000/W to QDR 2000
    • Faulkner KG, Glüer CC, Estilo M, Genant HK. 1993 Cross-calibration of DXA equipment: upgrading from Hologic QDR 1000/W to QDR 2000. Calcif Tissue Int 52:79-89.
    • (1993) Calcif Tissue Int , vol.52 , pp. 79-89
    • Faulkner, K.G.1    Glüer, C.C.2    Estilo, M.3    Genant, H.K.4
  • 5
    • 0031044738 scopus 로고    scopus 로고
    • Decreased bone mass and strength in ovariectomized Cynomolgus monkeys (Macacafascicularis)
    • Jerome CP, Turner CH, Lees CJ. 1997 Decreased bone mass and strength in ovariectomized Cynomolgus monkeys (Macacafascicularis). Calcif Tissue Int 60:265-270.
    • (1997) Calcif Tissue Int , vol.60 , pp. 265-270
    • Jerome, C.P.1    Turner, C.H.2    Lees, C.J.3
  • 6
    • 0030037280 scopus 로고    scopus 로고
    • Replacing DXA scanners: Cross-calibration with phantoms may be misleading
    • Blake GM. 1996 Replacing DXA scanners: cross-calibration with phantoms may be misleading. Calcif Tissue Int 59:1-5.
    • (1996) Calcif Tissue Int , vol.59 , pp. 1-5
    • Blake, G.M.1
  • 7
    • 0026319113 scopus 로고
    • Bone induction in non-human primates. An experimental study on the baboon (Papio ursinus)
    • Ripamonti U. 1991 Bone induction in non-human primates. An experimental study on the baboon (Papio ursinus). Clin Orthop 269:284-294.
    • (1991) Clin Orthop , vol.269 , pp. 284-294
    • Ripamonti, U.1
  • 9
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. 1986 Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 8:307-310.
    • (1986) Lancet , vol.8 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 0025358771 scopus 로고
    • Accuracy of dual-energy radiographic absorptiometry of the lumbar spine: Cadaver study
    • Ho CP, Kim RW, Schaffer MB, Sartoris DJ. 1990 Accuracy of dual-energy radiographic absorptiometry of the lumbar spine: cadaver study. Radiology 176:171-173.
    • (1990) Radiology , vol.176 , pp. 171-173
    • Ho, C.P.1    Kim, R.W.2    Schaffer, M.B.3    Sartoris, D.J.4
  • 11
    • 0027504762 scopus 로고
    • Dual x-ray absorptiometry: A comparison between fan beam and pencil beam scans
    • Blake GM, Parker JC, Buxton FMA, Fogelman I. 1993 Dual x-ray absorptiometry: a comparison between fan beam and pencil beam scans. Br J Radiol 66:902-906.
    • (1993) Br J Radiol , vol.66 , pp. 902-906
    • Blake, G.M.1    Parker, J.C.2    Buxton, F.M.A.3    Fogelman, I.4
  • 13
    • 0029123724 scopus 로고
    • Cross calibration of QDR-2000 and QDR-1000 dual energy x-ray densitometers for bone mineral and soft-tissue measurements
    • Abrahamsen B, Gram J, Hansen TB, Beck-Nielsen H. 1995. Cross calibration of QDR-2000 and QDR-1000 dual energy x-ray densitometers for bone mineral and soft-tissue measurements. Bone 16:385-390.
    • (1995) Bone , vol.16 , pp. 385-390
    • Abrahamsen, B.1    Gram, J.2    Hansen, T.B.3    Beck-Nielsen, H.4
  • 14
    • 0027742340 scopus 로고
    • Diagnostic tools and biological markers: Animal models in the study of osteoporosis and oral bone loss
    • Aufdemorte TB, Boyan BD, Fox WC, Miller D. 1993 Diagnostic tools and biological markers: animal models in the study of osteoporosis and oral bone loss. J Bone Miner Res 8, S529-S534.
    • (1993) J Bone Miner Res , vol.8
    • Aufdemorte, T.B.1    Boyan, B.D.2    Fox, W.C.3    Miller, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.