메뉴 건너뛰기




Volumn 16, Issue 5, 2002, Pages 552-556

Partial coherence laser interferometry vs conventional ultrasound biometry in intraocular lens power calculations

Author keywords

A constant; Biometry; Intraocular lens; IOL power formulae; Partial coherence laser interferometry; Ultrasound A scan

Indexed keywords

ACCURACY; ADULT; AGED; ANALYTICAL ERROR; ARTICLE; BIOMETRY; CALCULATION; CATARACT; CATARACT EXTRACTION; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; EYE REFRACTION; HUMAN; INTERFEROMETRY; INTERMETHOD COMPARISON; LASER; LENS IMPLANT; LENS POWER; MAJOR CLINICAL STUDY; PHACOEMULSIFICATION; POSTOPERATIVE PERIOD; PREOPERATIVE EVALUATION; PROSPECTIVE STUDY; RANDOMIZED CONTROLLED TRIAL; RETINA MACULA DEGENERATION; RETROSPECTIVE STUDY; STANDARDIZATION; STATISTICAL ANALYSIS; ULTRASOUND;

EID: 0036740708     PISSN: 0950222X     EISSN: None     Source Type: Journal    
DOI: 10.1038/sj.eye.6700157     Document Type: Article
Times cited : (189)

References (24)
  • 1
    • 0026990947 scopus 로고
    • Sources of error in intraocular lens power calculation
    • Olsen T. Sources of error in intraocular lens power calculation. J Cataract Refract Surg 1992; 18: 125-129.
    • (1992) J. Cataract Refract. Surg , vol.18 , pp. 125-129
    • Olsen, T.1
  • 2
    • 0027442385 scopus 로고
    • The Hoffer Q formula: A comparison of theoretic and regression formulas
    • Hoffer KJ. The Hoffer Q formula: a comparison of theoretic and regression formulas. J Cataract Refract Surg 1993; 19: 700-712.
    • (1993) J. Cataract Refract. Surg , vol.19 , pp. 700-712
    • Hoffer, K.J.1
  • 3
    • 0019432970 scopus 로고
    • The accuracy of ultrasonic measurement of the axial length of the eye
    • Binkhorst RD. The accuracy of ultrasonic measurement of the axial length of the eye. Ophthalmic Surg 1981; 12: 363-365.
    • (1981) Ophthalmic Surg , vol.12 , pp. 363-365
    • Binkhorst, R.D.1
  • 4
    • 0022449921 scopus 로고
    • Improving the predictability of intraocular lens power calculations
    • Holladay JT, Prager TC et al. Improving the predictability of intraocular lens power calculations. Arch Ophthalmol 1986; 104: 539-541.
    • (1986) Arch. Ophthalmol , vol.104 , pp. 539-541
    • Holladay, J.T.1    Prager, T.C.2
  • 5
    • 0023105263 scopus 로고
    • Theoretical approach to intraocular lens calculation using Gaussian optics
    • Olsen T. Theoretical approach to intraocular lens calculation using Gaussian optics. J Cataract Refract Surg 1987; 13: 141-145.
    • (1987) J. Cataract Refract. Surg , vol.13 , pp. 141-145
    • Olsen, T.1
  • 6
    • 0024309262 scopus 로고
    • The accuracy of ultrasonic determination of axial length in pseudophakic eyes
    • Oslen T. The accuracy of ultrasonic determination of axial length in pseudophakic eyes. Acta Ophthalmol (Copenh) 1990; 67: 141-144.
    • (1990) Acta Ophthalmol. (Copenh) , vol.67 , pp. 141-144
    • Oslen, T.1
  • 7
    • 0001990533 scopus 로고
    • Diagnostic ultrasound
    • Webb S (ed). Philadelphia: Adam Hilger
    • Bamber JC, Tristam M. Diagnostic ultrasound. In: Webb S (ed). The Physics of Medical Imaging. Philadelphia: Adam Hilger, 1988, pp 319-388.
    • (1988) The Physics of Medical Imaging , pp. 319-388
    • Bamber, J.C.1    Tristam, M.2
  • 8
    • 84975538971 scopus 로고
    • Eye length measurement by interferometry with partial coherent light
    • Fercher AF, Mengedoht K, Werner W. Eye length measurement by interferometry with partial coherent light. Opt Lett 1988; 13: 186-188.
    • (1988) Opt. Lett , vol.13 , pp. 186-188
    • Fercher, A.F.1    Mengedoht, K.2    Werner, W.3
  • 9
    • 0026254046 scopus 로고
    • Optical coherence tomography
    • Huang D, Swanson EA, Lin CP et al. Optical coherence tomography. Science 1991; 254: 1178-1181.
    • (1991) Science , vol.254 , pp. 1178-1181
    • Huang, D.1    Swanson, E.A.2    Lin, C.P.3
  • 10
    • 0026101781 scopus 로고
    • Optical measurement of the axial length by laser Doppler interferometer
    • Hitzenberger CK. Optical measurement of the axial length by laser Doppler interferometer. Invest Ophthalmol Vis Sci 1991; 32: 616-624.
    • (1991) Invest. Ophthalmol. Vis. Sci , vol.32 , pp. 616-624
    • Hitzenberger, C.K.1
  • 11
    • 0027196531 scopus 로고
    • Measurement of the axial length of cataract eyes by laser Doppler interferometry
    • Hitzenberger CK et al. Measurement of the axial length of cataract eyes by laser Doppler interferometry. Invest Ophthalmol Vis Sci 1993; 34: 1886-1893.
    • (1993) Invest. Ophthalmol. Vis. Sci , vol.34 , pp. 1886-1893
    • Hitzenberger, C.K.1
  • 12
    • 0031673184 scopus 로고    scopus 로고
    • Dual beam optical coherence tomography: Signal identification for ophthalmologic diagnosis
    • Drexler W, Findl O et al. Dual beam optical coherence tomography: signal identification for ophthalmologic diagnosis. J Biomed Opt 1998; 3: 55-65.
    • (1998) J. Biomed. Opt , vol.3 , pp. 55-65
    • Drexler, W.1    Findl, O.2
  • 13
    • 0001788489 scopus 로고    scopus 로고
    • Measurements of the posterior structures of the human eye in vivo by partial coherence interferometry using diffractive optics
    • Baumgartner A et al. Measurements of the posterior structures of the human eye in vivo by partial coherence interferometry using diffractive optics. Proc SPIE 1997; 2981: 85-91.
    • (1997) Proc. SPIE , vol.2981 , pp. 85-91
    • Baumgartner, A.1
  • 14
    • 0031928879 scopus 로고    scopus 로고
    • High precision biometry of pseudophakic eyes using partial coherence interferometry
    • Findl O et al. High precision biometry of pseudophakic eyes using partial coherence interferometry. J Cataract Refract Surg 1998; 24: 1087-1093.
    • (1998) J. Cataract Refract. Surg , vol.24 , pp. 1087-1093
    • Findl, O.1
  • 15
    • 0004077521 scopus 로고    scopus 로고
    • Cataract Surgery Guidelines
    • The Royal College of Ophthalmologists RCO: UK, Feb
    • The Royal College of Ophthalmologists. Cataract Surgery Guidelines. RCO: UK, Feb 2001.
    • (2001)
  • 16
    • 0032190258 scopus 로고    scopus 로고
    • Partial coherence interferometry: A novel approach to biometry in cataract surgery
    • Drexler W et al. Partial coherence interferometry: a novel approach to biometry in cataract surgery. Am J Ophthalmol 1998; 126: 524-534.
    • (1998) Am. J. Ophthalmol , vol.126 , pp. 524-534
    • Drexler, W.1
  • 17
    • 0034965748 scopus 로고    scopus 로고
    • Improved prediction of intraocular lens power using partial coherence interferometry
    • Findl O et al. Improved prediction of intraocular lens power using partial coherence interferometry. J Cataract Refract Surg 2001; 27: 861-867.
    • (2001) J. Cataract Refract. Surg , vol.27 , pp. 861-867
    • Findl, O.1
  • 18
    • 0021246896 scopus 로고
    • Influence of intraocular lenses on ultrasound axial length measurement: In vitro and in vivo studies
    • Freudiger H et al. Influence of intraocular lenses on ultrasound axial length measurement: in vitro and in vivo studies. Am Intraocular Implant Soc J 1984; 10: 29-34.
    • (1984) Am. Intraocular Implant. Soc. J , vol.10 , pp. 29-34
    • Freudiger, H.1
  • 19
    • 0018937490 scopus 로고
    • Biometry on 7500 cataractous eyes
    • Hoffer KJ. Biometry on 7500 cataractous eyes. Am J Ophthal 1980; 90: 360-368.
    • (1980) Am. J. Ophthal , vol.90 , pp. 360-368
    • Hoffer, K.J.1
  • 20
    • 0016722639 scopus 로고
    • Determination of the expected power of the implant lens by ultrasound
    • Oguchi Y et al. Determination of the expected power of the implant lens by ultrasound. Ophthalmologica 1975; 171: 281-283.
    • (1975) Ophthalmologica , vol.171 , pp. 281-283
    • Oguchi, Y.1
  • 21
    • 0016800292 scopus 로고
    • Ultrasonography and lens implantation
    • Leonard PAM. Ultrasonography and lens implantation. Ophthalmologica 1975; 171: 276-277.
    • (1975) Ophthalmologica , vol.171 , pp. 276-277
    • Leonard, P.A.M.1
  • 22
    • 0024398757 scopus 로고
    • Axial length following implantation of posterior chamber lenses
    • Naeser K et al. Axial length following implantation of posterior chamber lenses. J Cataract Refract Surg 1989; 15: 673-675.
    • (1989) J. Cataract Refract. Surg , vol.15 , pp. 673-675
    • Naeser, K.1
  • 23
    • 0031915674 scopus 로고    scopus 로고
    • Investigation of dispersive effects in ocular media by multiple wavelength partial coherence interferometer
    • Drexler W et al. Investigation of dispersive effects in ocular media by multiple wavelength partial coherence interferometer. Exp Eye Res 1998; 66: 25-33.
    • (1998) Exp. Eye Res , vol.66 , pp. 25-33
    • Drexler, W.1
  • 24
    • 0036168821 scopus 로고    scopus 로고
    • Refractive outcome of cataract surgery using partial coherence interferometry and ultrasound biometry; clinical feasibility study of a commercial prototype II
    • Kiss B et al. Refractive outcome of cataract surgery using partial coherence interferometry and ultrasound biometry; clinical feasibility study of a commercial prototype II. J Cataract Refract Surg 2002; 28: 230-234.
    • (2002) J. Cataract. Refract. Surg , vol.28 , pp. 230-234
    • Kiss, B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.