Volumn 45, Issue 9, 2002, Pages 1154-1163
|
Artificial anal sphincter: Complications and functional results of a large personal series
a a a a a a a a |
Author keywords
ABS; Acticon ; Anal incontinence; Artificial anal sphincter; Fecal incontinence
|
Indexed keywords
ADOLESCENT;
ADULT;
AGED;
ANORECTAL PRESSURE;
ANUS SPHINCTER;
ARTICLE;
ARTIFICIAL ANUS SPHINCTER;
BLEEDING;
COLOSTOMY;
DEVICE;
ENDOSCOPIC ECHOGRAPHY;
FECES IMPACTION;
FECES INCONTINENCE;
FEMALE;
HUMAN;
IMPLANT;
INFECTION;
MAJOR CLINICAL STUDY;
MALE;
MANOMETRY;
MORBIDITY;
PERFORATION;
POSTOPERATIVE COMPLICATION;
PREOPERATIVE EVALUATION;
PROSTHESIS FAILURE;
QUALITY OF LIFE;
RECTOCELE;
RECTUM PERFORATION;
RISK FACTOR;
SCORING SYSTEM;
SEPSIS;
SKIN ULCER;
SPHINCTEROPLASTY;
STOMA;
SURGICAL TECHNIQUE;
URETHRA PERFORATION;
VAGINA INJURY;
WOUND DEHISCENCE;
WOUND INFECTION;
ADOLESCENT;
ADULT;
AGED;
ANAL CANAL;
FECAL INCONTINENCE;
FEMALE;
HUMANS;
MALE;
MANOMETRY;
MIDDLE AGED;
POSTOPERATIVE COMPLICATIONS;
PROSTHESES AND IMPLANTS;
PROSTHESIS IMPLANTATION;
QUALITY OF LIFE;
RETROSPECTIVE STUDIES;
STATISTICS, NONPARAMETRIC;
TREATMENT OUTCOME;
|
EID: 0036734291
PISSN: 00123706
EISSN: None
Source Type: Journal
DOI: 10.1007/s10350-004-6382-y Document Type: Article |
Times cited : (90)
|
References (9)
|