Volumn 44, Issue 9, 2002, Pages 2131-2151

Determination of instantaneous corrosion rates and runoff rates of copper from naturally patinated copper during continuous rain events

Author keywords

A. copper; Artificial rain; C. atmospheric corrosion; Corrosion rate; Electrochemical impedance spectroscopy; Runoff rate

Indexed keywords

COPPER; ELECTRIC CONDUCTIVITY; ELECTROCHEMISTRY; PAINTING; RAIN; RUNOFF; SPECTROSCOPY;

EID: 0036721861     PISSN: 0010938X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0010-938X(02)00015-X     Document Type: Article
Times cited : (90)

References (36)
  • 29
    • 2142850467 scopus 로고    scopus 로고
    • UN/ECE International Co-operative programme on effects on materials, including historic and cultural monuments, Evaluation after 8 years of exposure. Report No. 23, Bavarian state conservation office Munich, Germany, May