메뉴 건너뛰기




Volumn 31, Issue 5, 2002, Pages 468-474

A comparison of the accuracy and safety of vertebral body pin placement using a fluoroscopically guided versus an open surgical approach: An in vitro study

Author keywords

[No Author keywords available]

Indexed keywords

ANIMALIA;

EID: 0036717791     PISSN: 01613499     EISSN: 1532950X     Source Type: Journal    
DOI: 10.1053/jvet.2002.33616     Document Type: Article
Times cited : (33)

References (25)
  • 1
    • 28644446689 scopus 로고    scopus 로고
    • Use of an external skeletal fixator to correct spinal fracture/luxation and instability in three dogs
    • Lanz OI, Jones JC, Bergman R: Use of an external skeletal fixator to correct spinal fracture/luxation and instability in three dogs. Vet Neuro and Neuro Surg 2(1): 2000 http:// www.neurovet.org/LanzSpinslFixator/LANZ1final.htm accessed 3/12/2001
    • (2000) Vet Neuro and Neuro Surg , vol.2 , Issue.1
    • Lanz, O.I.1    Jones, J.C.2    Bergman, R.3
  • 2
    • 0024708939 scopus 로고
    • Combined Kirschner-Ehmer device and dorsal spinal plate fixation technique for caudal lumbar vertebral fractures in dogs
    • Shores A, Nichols C, Rochat M, et al: Combined Kirschner-Ehmer device and dorsal spinal plate fixation technique for caudal lumbar vertebral fractures in dogs. J Am Vet Med Assoc 195:335-339, 1989
    • (1989) J Am Vet Med Assoc , vol.195 , pp. 335-339
    • Shores, A.1    Nichols, C.2    Rochat, M.3
  • 3
    • 0041297444 scopus 로고
    • Kirschner-Ehmer device alone to stabilize caudal lumbar fractures in small dogs
    • Philips L, Blackmore J: Kirschner-Ehmer device alone to stabilize caudal lumbar fractures in small dogs. Vet Comp Orthop Trauma 4:112-115, 1991
    • (1991) Vet Comp Orthop Trauma , vol.4 , pp. 112-115
    • Philips, L.1    Blackmore, J.2
  • 4
    • 0026456273 scopus 로고
    • Fractures and luxations of the vertebral column
    • Shores A: Fractures and luxations of the vertebral column. Vet Clin North Am Small Anim Pract 22:171-181, 1992
    • (1992) Vet Clin North Am Small Anim Pract , vol.22 , pp. 171-181
    • Shores, A.1
  • 5
    • 0042260560 scopus 로고    scopus 로고
    • Managing spinal fractures and luxations in dogs
    • Lanz OI, Bergman R, Shell L: Managing spinal fractures and luxations in dogs. Vet Med 95:868-875, 2000
    • (2000) Vet Med , vol.95 , pp. 868-875
    • Lanz, O.I.1    Bergman, R.2    Shell, L.3
  • 6
    • 0036517493 scopus 로고    scopus 로고
    • External fixation of the lumbar spine in a canine model
    • Walker TM, Pierce WA, Welch RD: External fixation of the lumbar spine in a canine model. Vet Surg 31:181-188, 2002
    • (2002) Vet Surg , vol.31 , pp. 181-188
    • Walker, T.M.1    Pierce, W.A.2    Welch, R.D.3
  • 7
    • 85030735519 scopus 로고    scopus 로고
    • Fluoroscopic placement of transfixation pins for the external skeletal fixation of the canine spine: An anatomic study
    • Lake Louise, Canada, February 24- March 3
    • Walker TM, Tucker R, Welch RD, et al: Fluoroscopic placement of transfixation pins for the external skeletal fixation of the canine spine: An anatomic study. Proceedings Veterinary Orthopedic Society 28th Annual Conference. Lake Louise, Canada, February 24- March 3, 2001
    • (2001) Proceedings Veterinary Orthopedic Society 28th Annual Conference
    • Walker, T.M.1    Tucker, R.2    Welch, R.D.3
  • 8
    • 84995132436 scopus 로고
    • Spinal fixation in dogs using steinmann pins and methylmethacrylate
    • Blass CE, Seim HB: Spinal fixation in dogs using steinmann pins and methylmethacrylate. Vet Surg 13:203-210, 1984
    • (1984) Vet Surg , vol.13 , pp. 203-210
    • Blass, C.E.1    Seim, H.B.2
  • 10
    • 0040863401 scopus 로고
    • Thoracolumbar spinal fractures/luxations: Surgical management
    • Matthiesen DT: Thoracolumbar spinal fractures/luxations: surgical management. Compend Contin Educ Pract Vet 5:867-878, 1983
    • (1983) Compend Contin Educ Pract Vet , vol.5 , pp. 867-878
    • Matthiesen, D.T.1
  • 11
    • 0016758253 scopus 로고
    • The use of methylmethacrylate for spinal stabilization
    • Rouse GP, Miller JI: The use of methylmethacrylate for spinal stabilization. Vet Surg 11:418-425, 1975
    • (1975) Vet Surg , vol.11 , pp. 418-425
    • Rouse, G.P.1    Miller, J.I.2
  • 13
    • 0035865652 scopus 로고    scopus 로고
    • Virtual fluoroscopy: Computer assisted fluoroscopic navigation
    • Foley KT, Simon DA, Rampersaund YR: Virtual fluoroscopy: Computer assisted fluoroscopic navigation. Spine 26:347-351, 2001
    • (2001) Spine , vol.26 , pp. 347-351
    • Foley, K.T.1    Simon, D.A.2    Rampersaund, Y.R.3
  • 14
    • 0034491195 scopus 로고    scopus 로고
    • Computer-assisted fluoroscopic targeting system for pedicle screw insertion
    • Choi WVV, Green BA, Levi AD: Computer-assisted fluoroscopic targeting system for pedicle screw insertion. Neurosurgery 47:872-878, 2000
    • (2000) Neurosurgery , vol.47 , pp. 872-878
    • Choi, W.V.V.1    Green, B.A.2    Levi, A.D.3
  • 15
    • 0033127496 scopus 로고    scopus 로고
    • Closed reduction and lag screw fixation of sacroiliac luxations and fractures
    • Tomlinson JL, Cook JL, Payne JT, et al: Closed reduction and lag screw fixation of sacroiliac luxations and fractures. Vet Surg 28:188-193, 1999
    • (1999) Vet Surg , vol.28 , pp. 188-193
    • Tomlinson, J.L.1    Cook, J.L.2    Payne, J.T.3
  • 16
    • 22444455850 scopus 로고    scopus 로고
    • Closed toggle pinning for canine traumatic coxofemoral luxation
    • Serdy MG, Schulz KS, Hornof W, et al: Closed toggle pinning for canine traumatic coxofemoral luxation. Vet Comp Orthop Traumatol 12:6-14, 1999
    • (1999) Vet Comp Orthop Traumatol , vol.12 , pp. 6-14
    • Serdy, M.G.1    Schulz, K.S.2    Hornof, W.3
  • 17
    • 0033191011 scopus 로고    scopus 로고
    • Fluoroscopically guided closed reduction and internal fixation of fractures of the lateral portion of the humeral condyle: Prospective clinical study of the technique and results in ten dogs
    • Cook JL, Tomlinson JL, Reed AL: Fluoroscopically guided closed reduction and internal fixation of fractures of the lateral portion of the humeral condyle: Prospective clinical study of the technique and results in ten dogs. Vet Surg 28:315-321, 1999
    • (1999) Vet Surg , vol.28 , pp. 315-321
    • Cook, J.L.1    Tomlinson, J.L.2    Reed, A.L.3
  • 19
    • 0028507325 scopus 로고
    • Biomechanical study of canine spinal fracture fixation using pins or bone screws with polymethylmethacrylate
    • Garcia JN, Bruce MK, Russell D, et al: Biomechanical study of canine spinal fracture fixation using pins or bone screws with polymethylmethacrylate. Vet Surg 23:322-329, 1994
    • (1994) Vet Surg , vol.23 , pp. 322-329
    • Garcia, J.N.1    Bruce, M.K.2    Russell, D.3
  • 22
    • 0029156076 scopus 로고
    • Placement of pedicle screws in the thoracic spine. Part I: Morphometric analysis of the thoracic vertebrae
    • Vaccaro AR, Rizzolo SJ, Allardyce TJ, et al: Placement of pedicle screws in the thoracic spine. Part I: Morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am 77:1193-1199, 1995
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1193-1199
    • Vaccaro, A.R.1    Rizzolo, S.J.2    Allardyce, T.J.3
  • 23
    • 0029098570 scopus 로고
    • Placement of pedicle screws in the thoracic spine. Part II: An anatomic and radiographic assessment
    • Vaccaro AR, Rizzolo SJ, Balderston RA, et al: Placement of pedicle screws in the thoracic spine. Part II: An anatomic and radiographic assessment. J Bone Joint Surg Am 77:1200-1206, 1995
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1200-1206
    • Vaccaro, A.R.1    Rizzolo, S.J.2    Balderston, R.A.3
  • 24
    • 0031204509 scopus 로고    scopus 로고
    • Radiation exposure to the orthopaedic surgical team during fluoroscopy: "How far is far enough?"
    • Mehlman CT, DiPasquale TG: Radiation exposure to the orthopaedic surgical team during fluoroscopy: "How far is far enough?" J Orthop Trauma 11:392-398, 1997
    • (1997) J Orthop Trauma , vol.11 , pp. 392-398
    • Mehlman, C.T.1    DiPasquale, T.G.2
  • 25
    • 0034667336 scopus 로고    scopus 로고
    • Radiation exposure to the spinal surgeon during fluoroscopically assisted pedicle screw insertion
    • Rampersaud YR, Foley KT, Shen AC, et al: Radiation exposure to the spinal surgeon during fluoroscopically assisted pedicle screw insertion. Spine 25:2637-2645, 2000
    • (2000) Spine , vol.25 , pp. 2637-2645
    • Rampersaud, Y.R.1    Foley, K.T.2    Shen, A.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.