메뉴 건너뛰기




Volumn 49, Issue 3-4, 2002, Pages 156-162

Feasibility of a new hollow fiber silicone membrane oxygenator for long-term ECMO application

Author keywords

Extracorporeal membrane oxygenation; Hollow fiber; Long term ex vivo study; Oxygenator; Silicone membrane

Indexed keywords

HEMOGLOBIN; SILICONE;

EID: 0036704517     PISSN: 13431420     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (19)
  • 2
    • 0015186961 scopus 로고
    • Extended term (to 16 days) partial extracorporeal blood gas exchange with the spiral membrane lung in unanesthetized lambs
    • Kolobow T, Spragg RG, Pierce JE, Zapol WM: Extended term (to 16 days) partial extracorporeal blood gas exchange with the spiral membrane lung in unanesthetized lambs. ASAIO Trans 17: 350-354, 1971
    • (1971) ASAIO Trans , vol.17 , pp. 350-354
    • Kolobow, T.1    Spragg, R.G.2    Pierce, J.E.3    Zapol, W.M.4
  • 4
    • 0009403642 scopus 로고    scopus 로고
    • Protain adsorption and platelet adhesion on the surface of an oxygenator membrane
    • Niimi Y, Yamane S, Yamaji K, Tayama E, Sueoka A, Nosé Y: Protain adsorption and platelet adhesion on the surface of an oxygenator membrane. ASAIO J 43: M706-M710, 1997
    • (1997) ASAIO J , vol.43
    • Niimi, Y.1    Yamane, S.2    Yamaji, K.3    Tayama, E.4    Sueoka, A.5    Nosé, Y.6
  • 5
    • 0032170059 scopus 로고    scopus 로고
    • Development of a silicone hollow fiber membrane oxygenator for ECMO application
    • Yamane S, Ohashi Y, Sueoka A, Sato K, Kuwana J, Nosé Y: Development of a silicone hollow fiber membrane oxygenator for ECMO application. ASAIO J 44: M384-M387, 1998
    • (1998) ASAIO J , vol.44
    • Yamane, S.1    Ohashi, Y.2    Sueoka, A.3    Sato, K.4    Kuwana, J.5    Nosé, Y.6
  • 11
    • 0023701091 scopus 로고
    • Prolonged extracorporeal membrane oxtgenation in sheep with a hollow fiber oxygenator and a centrifugal pump
    • Palder SB, Shaheen KW, Whittelessy GC, Nowlen TT, Kundu SK, Klein MD: Prolonged extracorporeal membrane oxtgenation in sheep with a hollow fiber oxygenator and a centrifugal pump. Trans ASAIO 34: 820-822, 1988
    • (1988) Trans ASAIO , vol.34 , pp. 820-822
    • Palder, S.B.1    Shaheen, K.W.2    Whittelessy, G.C.3    Nowlen, T.T.4    Kundu, S.K.5    Klein, M.D.6
  • 13
    • 0026499671 scopus 로고
    • Plasma leakage through microporous membranes: Role of phospholipids
    • Montoya JP, Shanley CJ, Merz SI, Bartlett RH: Plasma leakage through microporous membranes: Role of phospholipids. ASAIO J 38: M399-M405, 1992
    • (1992) ASAIO J , vol.38
    • Montoya, J.P.1    Shanley, C.J.2    Merz, S.I.3    Bartlett, R.H.4
  • 14
    • 0025907947 scopus 로고
    • Bloodless testing for microporous membrane oxygenator failure: A preliminary study
    • Tamari Y, Tortolani AJ, Lee-Sensiba KJ: Bloodless testing for microporous membrane oxygenator failure: A preliminary study. Int J Artif Organs 14: 154-160, 1991
    • (1991) Int J Artif Organs , vol.14 , pp. 154-160
    • Tamari, Y.1    Tortolani, A.J.2    Lee-Sensiba, K.J.3
  • 15
    • 0025882264 scopus 로고
    • An in vitro technique to assess oxygenator potential for respiratory failure therapies
    • Kawak AM, Gaylor JDS, Simpson K, Kirkland M: An in vitro technique to assess oxygenator potential for respiratory failure therapies. Int J Artif Organs 14: 234-238, 1991
    • (1991) Int J Artif Organs , vol.14 , pp. 234-238
    • Kawak, A.M.1    Gaylor, J.D.S.2    Simpson, K.3    Kirkland, M.4
  • 17
    • 0026587075 scopus 로고
    • An approach to the microporous hollow fiber for the ECMO oxygenator-micropore characteristics of the gas exchange performance, plasma leakage, and hydrophilization of the inner surface of fibers
    • Hagiwara K, Innami K, Yokoyama K, Kitoh H, Nogawa A, Muramoto T, Tatebe K, Seita Y, Fukasawa H: An approach to the microporous hollow fiber for the ECMO oxygenator-micropore characteristics of the gas exchange performance, plasma leakage, and hydrophilization of the inner surface of fibers. Jpn J Artif Organs (in Japanese) 21: 720-726, 1992
    • (1992) Jpn J Artif Organs (in Japanese) , vol.21 , pp. 720-726
    • Hagiwara, K.1    Innami, K.2    Yokoyama, K.3    Kitoh, H.4    Nogawa, A.5    Muramoto, T.6    Tatebe, K.7    Seita, Y.8    Fukasawa, H.9
  • 18
    • 0029878984 scopus 로고    scopus 로고
    • Current status of extracorporeal membrane oxygenation for severe respiratory failure
    • Ichiba S, Bartlett RH: Current status of extracorporeal membrane oxygenation for severe respiratory failure. Artif Organs 20: 120-123, 1996
    • (1996) Artif Organs , vol.20 , pp. 120-123
    • Ichiba, S.1    Bartlett, R.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.