메뉴 건너뛰기




Volumn 29, Issue 8, 2002, Pages 1859-1866

Optimization of Ga-67 imaging for detection and estimation tasks: Dependence of imaging performance on spectral acquisition parameters

Author keywords

Bayesian estimator; Cramer Rao bound; Detection; Estimation; Ga 67 imaging; Task based optimization

Indexed keywords

CRAMER-RAO BOUNDS; ERROR DETECTION; ESTIMATION; PHANTOMS; SPHERES;

EID: 0036703560     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1493214     Document Type: Article
Times cited : (9)

References (16)
  • 1
    • 0000232569 scopus 로고    scopus 로고
    • Quantification of gallium-67 avidity as a function of the histology in patients with non-Hodgkin's lymphoma
    • A. D. Van Den Abeele, F. J. Rybicki, D. M. Cowart, and K. M. Kehoe, "Quantification of gallium-67 avidity as a function of the histology in patients with non-Hodgkin's lymphoma," J. Nucl. Med. 38, 238 (1997).
    • (1997) J. Nucl. Med. , vol.38 , pp. 238
    • Van Den Abeele, A.D.1    Rybicki, F.J.2    Cowart, D.M.3    Kehoe, K.M.4
  • 4
    • 0029006731 scopus 로고
    • Collimator optimization for lesion detection incorporating prior information about lesion size
    • S. C. Moore, D. J. de Vries, B. Nandram, M. F. Kijewski, and S. P. Mueller, "Collimator optimization for lesion detection incorporating prior information about lesion size," Med. Phys. 22, 703-713 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 703-713
    • Moore, S.C.1    De Vries, D.J.2    Nandram, B.3    Kijewski, M.F.4    Mueller, S.P.5
  • 6
    • 0035355162 scopus 로고    scopus 로고
    • Realistic Monte Carlo simulation of Ga-67 SPECT imaging
    • S. C. Moore and G. El Fakhri, "Realistic Monte Carlo simulation of Ga-67 SPECT imaging," IEEE Trans. Nucl. Sci. 48, 720-724 (2001).
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , pp. 720-724
    • Moore, S.C.1    El Fakhri, G.2
  • 9
    • 0025083990 scopus 로고
    • Maximum-likelihood estimation: A mathematical model for quantitation in nuclear medicine
    • S. P. Müller, M. F. Kijewski, S. C. Moore, and B. L. Holman, "Maximum-likelihood estimation: A mathematical model for quantitation in nuclear medicine," J. Nucl. Med. 31, 1693-1701 (1989).
    • (1989) J. Nucl. Med. , vol.31 , pp. 1693-1701
    • Müller, S.P.1    Kijewski, M.F.2    Moore, S.C.3    Holman, B.L.4
  • 10
    • 0021848431 scopus 로고
    • Unified SNR analysis of medical imaging systems
    • R. F. Wagner and D. G. Brown, "Unified SNR analysis of medical imaging systems," Phys. Med. Biol. 30, 489-518 (1985).
    • (1985) Phys. Med. Biol. , vol.30 , pp. 489-518
    • Wagner, R.F.1    Brown, D.G.2
  • 11
    • 0011694871 scopus 로고
    • Generalized ideal observer models for design and evaluation of medical imaging systems
    • M. Kijewski, S. Müller, S. Moore, and F. Rybicki, "Generalized ideal observer models for design and evaluation of medical imaging systems," Radiology 177, 208 (1990).
    • (1990) Radiology , vol.177 , pp. 208
    • Kijewski, M.1    Müller, S.2    Moore, S.3    Rybicki, F.4
  • 12
    • 0026572462 scopus 로고
    • Collimator design for single photon emission tomography
    • S. C. Moore, K. Kouris, and I. Cullum, "Collimator design for single photon emission tomography," Eur. J. Nucl. Med. 19, 138-150 (1992).
    • (1992) Eur. J. Nucl. Med. , vol.19 , pp. 138-150
    • Moore, S.C.1    Kouris, K.2    Cullum, I.3
  • 13
    • 0018194574 scopus 로고
    • A comparison of optimum detector spatial resolution in nuclear imaging based on statistical theory and on observer performance
    • B. M. W. Tsui, C. E. Metz, F. B. Atkins, S. J. Starr, and R. N. Beck, "A comparison of optimum detector spatial resolution in nuclear imaging based on statistical theory and on observer performance," Phys. Med. Biol. 23, 654-676 (1978).
    • (1978) Phys. Med. Biol. , vol.23 , pp. 654-676
    • Tsui, B.M.W.1    Metz, C.E.2    Atkins, F.B.3    Starr, S.J.4    Beck, R.N.5
  • 14
    • 0018119383 scopus 로고
    • A correction to 'A comparison of optimum detector spatial resolution in nuclear imaging based on statistical theory and on observer performance'
    • B. M. W. Tsui, "A correction to 'A comparison of optimum detector spatial resolution in nuclear imaging based on statistical theory and on observer performance,'" Phys. Med. Biol. 23, 1203 (1978).
    • (1978) Phys. Med. Biol. , vol.23 , pp. 1203
    • Tsui, B.M.W.1
  • 15
    • 0023502720 scopus 로고
    • Addition of a channel mechanism to the ideal-observer model
    • K. J. Myers and H. H. Barrett, "Addition of a channel mechanism to the ideal-observer model," J. Opt. Soc. Am. A 4, 2447-2457 (1987).
    • (1987) J. Opt. Soc. Am. A , vol.4 , pp. 2447-2457
    • Myers, K.J.1    Barrett, H.H.2
  • 16
    • 0035286822 scopus 로고    scopus 로고
    • Human- and model-observer performance in ramp-spectrum noise: Effects of regularization and object variability
    • C. Abbey and H. Barrett, "Human- and model-observer performance in ramp-spectrum noise: effects of regularization and object variability," J. Opt. Soc. Am. A 18, 473-488 (2001).
    • (2001) J. Opt. Soc. Am. A , vol.18 , pp. 473-488
    • Abbey, C.1    Barrett, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.