메뉴 건너뛰기




Volumn 124, Issue 3, 2002, Pages 293-302

Embedded active sensors for in-situ structural health monitoring of thin-wall structures

Author keywords

[No Author keywords available]

Indexed keywords

AIRCRAFT; CRACKS; PIEZOELECTRIC DEVICES; THIN WALLED STRUCTURES; ULTRASONIC WAVES;

EID: 0036700996     PISSN: 00949930     EISSN: None     Source Type: Journal    
DOI: 10.1115/1.1484117     Document Type: Article
Times cited : (67)

References (21)
  • 1
    • 0036398636 scopus 로고    scopus 로고
    • Embedded self-sensing piezoelectric active sensors for on-line structural identification
    • Jan.
    • Giurgiutiu, V., and Zagrai, A., 2002, "Embedded Self-Sensing Piezoelectric Active Sensors for On-Line Structural Identification," ASME J. Vibr. Acoust. 124, Jan., pp. 116-125.
    • (2002) ASME J. Vibr. Acoust. , vol.124 , pp. 116-125
    • Giurgiutiu, V.1    Zagrai, A.2
  • 4
    • 0035360397 scopus 로고    scopus 로고
    • Ways and options for aircraft structural health monitoring
    • Boller, C., 2001, "Ways and Options for Aircraft Structural Health Monitoring," Smart Mater. Struct., 10, pp. 432-440.
    • (2001) Smart Mater. Struct. , vol.10 , pp. 432-440
    • Boller, C.1
  • 5
    • 0004048477 scopus 로고
    • ANSI/IEEE Std. 176, The Institute of Electrical and Electronics Engineers, Inc.
    • ANSI/IEEE Std. 176, 1987, IEEE Standard on Piezoelectricity, The Institute of Electrical and Electronics Engineers, Inc.
    • (1987) IEEE Standard on Piezoelectricity
  • 8
    • 0021412026 scopus 로고
    • The impedance method for non-destructive inspection
    • Cawley, P., 1984, "The Impedance Method for Non-Destructive Inspection," NDT Int., 17, No. 2, pp. 59-65.
    • (1984) NDT Int. , vol.17 , Issue.2 , pp. 59-65
    • Cawley, P.1
  • 9
    • 0034769681 scopus 로고    scopus 로고
    • Electro-mechanical impedance method for crack detection in metallic plates
    • March 4-8, Newport Beach, CA, Paper No. 4335-22 (in press)
    • Giurgiutiu, V., and Zagrai, A., 2001, "Electro-Mechanical Impedance Method for Crack Detection in Metallic Plates," SPIE's 8th Annual International Symposium on Smart Structures and Materials, March 4-8, Newport Beach, CA, Paper No. 4335-22 (in press).
    • (2001) SPIE's 8th Annual International Symposium on Smart Structures and Materials
    • Giurgiutiu, V.1    Zagrai, A.2
  • 11
    • 0034248967 scopus 로고    scopus 로고
    • Performance of smart piezoelectric patches in health monitoring of an RC bridge
    • Aug.
    • Soh, C.K., Tseng, K.K.-H., Bhalla, S., and Gupta, A., 2000, "Performance of Smart Piezoelectric Patches in Health Monitoring of an RC Bridge," Smart Mater. Struct., 9, Aug., pp. 533-542.
    • (2000) Smart Mater. Struct. , vol.9 , pp. 533-542
    • Soh, C.K.1    Tseng, K.K.-H.2    Bhalla, S.3    Gupta, A.4
  • 12
    • 0036610654 scopus 로고    scopus 로고
    • Non-parametric damage detection and characterization using smart piezoceramic material
    • in press
    • Tseng, K.K.-H., Soh, C.K., and Naidu, A.S.K., 2002, "Non-Parametric Damage Detection and Characterization Using Smart Piezoceramic Material," Smart Mater. Struct. (in press).
    • (2002) Smart Mater. Struct.
    • Tseng, K.K.-H.1    Soh, C.K.2    Naidu, A.S.K.3
  • 16
    • 0002288201 scopus 로고    scopus 로고
    • Damage localization in composite plates using wavelet transform processing on lamb wave signals
    • Stanford University, September 8-10
    • Lemistre, M., Gouyon, R., Kaczmarek, H., and Balageas, D., 1999, "Damage Localization in Composite Plates Using Wavelet Transform Processing on Lamb Wave Signals," 2nd International Workshop of StructuraI Health Monitoring, Stanford University, September 8-10, pp. 861-870.
    • (1999) 2nd International Workshop of StructuraI Health Monitoring , pp. 861-870
    • Lemistre, M.1    Gouyon, R.2    Kaczmarek, H.3    Balageas, D.4
  • 17
    • 0029370143 scopus 로고
    • Identifying delaminations in composite beams using built-in piezoelectrics: Part I - Experiments and analysis; Part II an identification method
    • Sept.
    • Keilers, C.H., and Chang, F.-K., 1995, "Identifying Delaminations in Composite Beams Using Built-in Piezoelectrics: Part I-Experiments and Analysis; Part II An Identification Method," J. Intell. Mater. Syst. Struct., 6, Sept., pp. 649-672.
    • (1995) J. Intell. Mater. Syst. Struct. , vol.6 , pp. 649-672
    • Keilers, C.H.1    Chang, F.-K.2
  • 18
    • 0003271159 scopus 로고    scopus 로고
    • Manufacturing and design of built-in diagnostics for composite structures
    • Virginia Beach, VA, March 30 - April 3
    • Chang, F.-K., 1998, "Manufacturing and Design of Built-in Diagnostics for Composite Structures," 52nd Meeting of Society for Machinery Failure Prevention Technology, Virginia Beach, VA, March 30 - April 3.
    • (1998) 52nd Meeting of Society for Machinery Failure Prevention Technology
    • Chang, F.-K.1
  • 19
    • 0012598895 scopus 로고    scopus 로고
    • Quick inspection of large structures using low frequency ultrasound
    • Fu-Kuo Chang, ed., Technomic, Inc.
    • Cawley, P., 1997, "Quick Inspection of Large Structures Using Low Frequency Ultrasound," Structural Health Monitoring - Current Status and Perspective, Fu-Kuo Chang, ed., Technomic, Inc.
    • (1997) Structural Health Monitoring - Current Status and Perspective
    • Cawley, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.