메뉴 건너뛰기




Volumn 88, Issue 2, 2002, Pages 151-158

Internal porosity of cast titanium removable partial dentures: Influence of sprue direction on porosity in circumferential clasps of a clinical framework design

Author keywords

[No Author keywords available]

Indexed keywords

TITANIUM; WAX;

EID: 0036676377     PISSN: 00223913     EISSN: None     Source Type: Journal    
DOI: 10.1067/mpr.2002.127400     Document Type: Article
Times cited : (14)

References (21)
  • 1
    • 0030227540 scopus 로고    scopus 로고
    • Ten-year evaluation of removable partial dentures: Survival rates based on retreatment, not wearing and replacement
    • Vermeulen AH, Keltjens HM, van't Hof MA, Kayser AF. Ten-year evaluation of removable partial dentures: survival rates based on retreatment, not wearing and replacement. J Prosthet Dent 1996;76:267-72.
    • (1996) J Prosthet Dent , vol.76 , pp. 267-272
    • Vermeulen, A.H.1    Keltjens, H.M.2    Van't Hof, M.A.3    Kayser, A.F.4
  • 2
    • 1842677897 scopus 로고
    • Fractures of cobalt-chromium castings
    • Harcourt HJ. Fractures of cobalt-chromium castings. Br Dent J 1961;110: 43-50.
    • (1961) Br Dent J , vol.110 , pp. 43-50
    • Harcourt, H.J.1
  • 3
    • 0017936951 scopus 로고
    • Failure of removable partial denture castings during service
    • Lewis AJ. Failure of removable partial denture castings during service. J Prosthet Dent 1978;39:147-9.
    • (1978) J Prosthet Dent , vol.39 , pp. 147-149
    • Lewis, A.J.1
  • 4
    • 0031159917 scopus 로고    scopus 로고
    • Titanium for removable dentures. II. Two-year clinical observations
    • Thomas CJ, Lechner S, Mori T. Titanium for removable dentures. II. Two-year clinical observations. J Oral Rehabil 1997;24:414-8.
    • (1997) J Oral Rehabil , vol.24 , pp. 414-418
    • Thomas, C.J.1    Lechner, S.2    Mori, T.3
  • 5
    • 0014020907 scopus 로고
    • Studies related to the fracture of partial dentures. The functional strain in cobalt-chromium dentures. A preliminary report
    • Bates JF. Studies related to the fracture of partial dentures. The functional strain in cobalt-chromium dentures. A preliminary report. Br Dent J 1966; 120:79-83.
    • (1966) Br Dent J , vol.120 , pp. 79-83
    • Bates, J.F.1
  • 6
    • 0023014817 scopus 로고
    • The fracture of cobalt-chromium alloy removable partial dentures
    • Ben-Ur Z, Patael H, Cardash HS, Baharav H. The fracture of cobalt-chromium alloy removable partial dentures. Quintessence Int 1986;17: 797-801.
    • (1986) Quintessence Int , vol.17 , pp. 797-801
    • Ben-Ur, Z.1    Patael, H.2    Cardash, H.S.3    Baharav, H.4
  • 7
    • 0022148350 scopus 로고
    • Radiographic detection of porosities in removable partial denture castings
    • Elarbi EA, Ismail YH, Azarbal M, Saini TS. Radiographic detection of porosities in removable partial denture castings. J Prosthet Dent 1985;54: 674-7.
    • (1985) J Prosthet Dent , vol.54 , pp. 674-677
    • Elarbi, E.A.1    Ismail, Y.H.2    Azarbal, M.3    Saini, T.S.4
  • 8
    • 0027584617 scopus 로고
    • Radiographic and metallographic evaluation of porosity defects and grain structure of cast chromium cobalt removable partial dentures
    • Dharmar S, Rathnasamy RJ, Swaminathan TN. Radiographic and metallographic evaluation of porosity defects and grain structure of cast chromium cobalt removable partial dentures. J Prosthet Dent 1993;69:369-73.
    • (1993) J Prosthet Dent , vol.69 , pp. 369-373
    • Dharmar, S.1    Rathnasamy, R.J.2    Swaminathan, T.N.3
  • 10
    • 0033160248 scopus 로고    scopus 로고
    • Investigation of the effect of three sprue designs on the porosity and the completeness of titanium cast removable partial denture frameworks
    • al-Mesmar HS, Morgano SM, Mark LE. Investigation of the effect of three sprue designs on the porosity and the completeness of titanium cast removable partial denture frameworks. J Prosthet Dent 1999;82:15-21.
    • (1999) J Prosthet Dent , vol.82 , pp. 15-21
    • Al-Mesmar, H.S.1    Morgano, S.M.2    Mark, L.E.3
  • 11
    • 0029311645 scopus 로고
    • Porosity and accuracy of multiple-unit titanium castings
    • Chai TI, Stein RS. Porosity and accuracy of multiple-unit titanium castings. J Prosthet Dent 1995;73:534-41.
    • (1995) J Prosthet Dent , vol.73 , pp. 534-541
    • Chai, T.I.1    Stein, R.S.2
  • 12
    • 0029421281 scopus 로고
    • Enhancement of a titanium denture frame model: Mold temperature and spruing factors
    • Vidovic Y, Chung HG, Mori T. Enhancement of a titanium denture frame model: mold temperature and spruing factors. Dent Mater J 1995;14:256-62.
    • (1995) Dent Mater J , vol.14 , pp. 256-262
    • Vidovic, Y.1    Chung, H.G.2    Mori, T.3
  • 13
    • 0031255468 scopus 로고    scopus 로고
    • The effects of sprue design on the roughness and porosity of titanium castings
    • Chan D, Guillory V, Blackman R, Chung KH. The effects of sprue design on the roughness and porosity of titanium castings. J Prosthet Dent 1997; 78:400-4.
    • (1997) J Prosthet Dent , vol.78 , pp. 400-404
    • Chan, D.1    Guillory, V.2    Blackman, R.3    Chung, K.H.4
  • 18
    • 0017944124 scopus 로고
    • Radiographic evaluation of porosities in removable partial denture castings
    • Lewis AJ. Radiographic evaluation of porosities in removable partial denture castings. J Prosthet Dent 1978;39:278-81.
    • (1978) J Prosthet Dent , vol.39 , pp. 278-281
    • Lewis, A.J.1
  • 21
    • 16144367589 scopus 로고
    • Mold filling of Ti castings using investments with different gas permeability
    • Syverud M, Herø H. Mold filling of Ti castings using investments with different gas permeability. Dent Mater 1995;11:14-8.
    • (1995) Dent Mater , vol.11 , pp. 14-18
    • Syverud, M.1    Herø, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.