메뉴 건너뛰기




Volumn 25, Issue 7, 2002, Pages 765-766

Internal fixation of a capitellum fracture using a biodegradable screw

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BIODEGRADABLE IMPLANT; BONE SCREW; CASE REPORT; ELBOW FLEXION; ELBOW FRACTURE; ELBOW RADIOGRAPHY; FEMALE; FRACTURE FIXATION; FRACTURE HEALING; FRACTURE REDUCTION; HUMAN; JOINT MOBILITY; OPEN REDUCTION; OSTEOSYNTHESIS; POSTOPERATIVE PERIOD; TREATMENT OUTCOME;

EID: 0036665355     PISSN: 01477447     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (12)
  • 1
    • 0029986978 scopus 로고    scopus 로고
    • Absorbable devices in the fixation of fractures
    • Rokkanen P, Bostman O, Vainionpaa S, et al. Absorbable devices in the fixation of fractures. J Trauma. 1996; 40:S123-S127.
    • (1996) J. Trauma , vol.40
    • Rokkanen, P.1    Bostman, O.2    Vainionpaa, S.3
  • 2
    • 3142600580 scopus 로고    scopus 로고
    • Absorbable implants in the treatment of distal humeral fractures in adolescents and adults
    • Pelto-Vasenius K, Hirvensalo E, Rokkanen P. Absorbable implants in the treatment of distal humeral fractures in adolescents and adults. Acta Orthop Belg. 1996; 62:93-102.
    • (1996) Acta Orthop. Belg. , vol.62 , pp. 93-102
    • Pelto-Vasenius, K.1    Hirvensalo, E.2    Rokkanen, P.3
  • 3
    • 0027416128 scopus 로고
    • Fracture of the humeral capitellum fixed with absorbable polyglycolide pins. 1-year follow-up of 8 adults
    • Hirvensalo E, Bostman O, Partio E, Tormala P, Rokkanen P. Fracture of the humeral capitellum fixed with absorbable polyglycolide pins. 1-year follow-up of 8 adults. Acta Orthop Scand. 1993; 64:85-86.
    • (1993) Acta Orthop. Scand. , vol.64 , pp. 85-86
    • Hirvensalo, E.1    Bostman, O.2    Partio, E.3    Tormala, P.4    Rokkanen, P.5
  • 4
  • 7
    • 0032104571 scopus 로고    scopus 로고
    • Fractures of the capitellum-a comparison of two fixation methods
    • Poynton AR, Kelly IP, O'Rourke SK. Fractures of the capitellum-a comparison of two fixation methods. Injury. 1998; 29:341-343.
    • (1998) Injury , vol.29 , pp. 341-343
    • Poynton, A.R.1    Kelly, I.P.2    O'Rourke, S.K.3
  • 8
    • 0030056334 scopus 로고    scopus 로고
    • Closed reduction of coronal fractures of the capitellum
    • Ochner RS, Bloom H, Palumbo RC, Coyle MP. Closed reduction of coronal fractures of the capitellum. J Trauma. 1996; 40:199-203.
    • (1996) J. Trauma , vol.40 , pp. 199-203
    • Ochner, R.S.1    Bloom, H.2    Palumbo, R.C.3    Coyle, M.P.4
  • 9
    • 0023196977 scopus 로고
    • Internal fixation of capitellar fractures using Herberts screws: A report of four cases
    • Richards RR, Khourry GW, Burke FD, Waddell JP. Internal fixation of capitellar fractures using Herberts screws: a report of four cases. Can J Surg. 1987; 30:188-191.
    • (1987) Can. J. Surg. , vol.30 , pp. 188-191
    • Richards, R.R.1    Khourry, G.W.2    Burke, F.D.3    Waddell, J.P.4
  • 10
    • 0028281555 scopus 로고
    • Herbert screw fixation of a capitellum fracture. A case report and review
    • Silveri CP, Corso SJ, Roofeh H. Herbert screw fixation of a capitellum fracture. A case report and review. Clin Orthop. 1994; 300:123-126.
    • (1994) Clin. Orthop. , vol.300 , pp. 123-126
    • Silveri, C.P.1    Corso, S.J.2    Roofeh, H.3
  • 11
    • 0026641588 scopus 로고
    • Biodegradable fixation of distal humeral physeal fractures
    • Makela EA, Bostman O, Kekomaki M. Biodegradable fixation of distal humeral physeal fractures. Clin Orthop. 1992; 283:237-243.
    • (1992) Clin. Orthop. , vol.283 , pp. 237-243
    • Makela, E.A.1    Bostman, O.2    Kekomaki, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.