메뉴 건너뛰기




Volumn 88, Issue 4, 2002, Pages 331-337

Clinical application and dosimetric calibration procedure of the superficial and orthovoltage therapy unit Therapax DXT300

Author keywords

Clinical indications; Dosimetric calibration; Orthovoltage therapy; Superficial therapy

Indexed keywords

ARTICLE; BEAM THERAPY; BIOMEDICAL TECHNOLOGY ASSESSMENT; CALIBRATION; COLLIMATOR; DOCUMENTATION; DOSIMETRY; MELANOMA; PALLIATIVE THERAPY; RADIATION APPLICATOR; RADIATION DOSE; SKIN CANCER; TREATMENT INDICATION;

EID: 0036658558     PISSN: 03008916     EISSN: None     Source Type: Journal    
DOI: 10.1177/030089160208800416     Document Type: Article
Times cited : (4)

References (17)
  • 2
    • 0002727404 scopus 로고
    • Carcinoma of the skin
    • Million RR, Cassisi NJ (Eds), JB Lippincot Company, Philadelphia
    • Million RR, Cassisi NJ: Carcinoma of the skin. In: Management of head and neck cancer, Million RR, Cassisi NJ (Eds), pp 643, JB Lippincot Company, Philadelphia, 1994.
    • (1994) Management of head and neck cancer , pp. 643
    • Million, R.R.1    Cassisi, N.J.2
  • 3
    • 4243521406 scopus 로고
    • Electron therapy for cutaneous epitheliomas
    • Zuppinger A et al. (Eds), Springer-Verlag, Berlin
    • Pourquier H: Electron therapy for cutaneous epitheliomas. In: High energy electrons in radiation therapy, Zuppinger A et al. (Eds), pp 48-51, Springer-Verlag, Berlin, 1980.
    • (1980) High energy electrons in radiation therapy , pp. 48-51
    • Pourquier, H.1
  • 4
    • 0025222621 scopus 로고
    • Aspetti fisico-tecnici dell'irradiazione cutanea totale con elettroni in alta intensità di dose
    • Scielzo G, Grillo Ruggeri F, Brunelli B, Bistolfi F: Aspetti fisico-tecnici dell'irradiazione cutanea totale con elettroni in alta intensità di dose. Radiol Med, 147-150, 1990.
    • (1990) Radiol Med , pp. 147-150
    • Scielzo, G.1    Grillo Ruggeri, F.2    Brunelli, B.3    Bistolfi, F.4
  • 5
    • 0028934336 scopus 로고
    • Randomized trial of hyperthermia as adjuvant to radiotherapy for recurrent or metastatic malignant melanoma
    • Overgaard J: Randomized trial of hyperthermia as adjuvant to radiotherapy for recurrent or metastatic malignant melanoma. The Lancet, 345: 540-543, 1995.
    • (1995) The Lancet , vol.345 , pp. 540-543
    • Overgaard, J.1
  • 6
    • 0010555524 scopus 로고    scopus 로고
    • Combination hyperthermia and radiation therapy for cutaneous malignant melanoma
    • Gabriele P, Ruo Redda MG, Nassisi D: Combination hyperthermia and radiation therapy for cutaneous malignant melanoma. PanMinerva Medica, 38 (2 Suppl 1): 18-19, 1996.
    • (1996) PanMinerva Medica , vol.38 , Issue.2 SUPPL. 1 , pp. 18-19
    • Gabriele, P.1    Ruo Redda, M.G.2    Nassisi, D.3
  • 8
    • 35348984002 scopus 로고    scopus 로고
    • Radiotherapy associated with hyperthermia in degenerative and inflammatory disorders: A prospective randomized trial
    • Gabriele P, Malinverni G, Delmastro E, Melossi L, Dal Fior S, Cutellè M: Radiotherapy associated with hyperthermia in degenerative and inflammatory disorders: a prospective randomized trial. Radioter Oncol, 53 (Suppl 1): S28, 1999.
    • (1999) Radioter Oncol , vol.53 , Issue.SUPPL. 1
    • Gabriele, P.1    Malinverni, G.2    Delmastro, E.3    Melossi, L.4    Dal Fior, S.5    Cutellè, M.6
  • 9
    • 25344473704 scopus 로고    scopus 로고
    • Radiotherapy in degenerative and inflammatory disorders: Retrospective analysis of our experience
    • Malinverni G, Rosmino C, Giordana C, Gabriele P: Radiotherapy in degenerative and inflammatory disorders: retrospective analysis of our experience. Radioter Oncol, 53 (Suppl 1): S27, 1999.
    • (1999) Radioter Oncol , vol.53 , Issue.SUPPL. 1
    • Malinverni, G.1    Rosmino, C.2    Giordana, C.3    Gabriele, P.4
  • 10
    • 25344468170 scopus 로고    scopus 로고
    • Cost and organization of radiotherapy for benign disease
    • Gabriele P: Cost and organization of radiotherapy for benign disease. Radioter Oncol, 53 (Suppl 1): S2, 1999.
    • (1999) Radioter Oncol , vol.53 , Issue.SUPPL. 1
    • Gabriele, P.1
  • 12
    • 0003484991 scopus 로고
    • Absorbed dose determination in photon and electron beams. An international code pratice
    • IAEA, Absorbed dose determination in photon and electron beams. An international code pratice. International Atomic Energy Agency Technical Report 277, 1987.
    • (1987) International Atomic Energy Agency Technical Report 277
  • 13
    • 0010637211 scopus 로고
    • Measurements of absorbed dose in a phantom irradiated by a single beam of X- or gamma rays
    • ICRU, Measurements of absorbed dose in a phantom irradiated by a single beam of X- or gamma rays. ICRU Report 23, 1973.
    • (1973) ICRU Report 23
  • 14
    • 0028024203 scopus 로고
    • Beam characteristics of the Therapax DXT300 orthovoltage therapy unit
    • Gregig L, Soubra M, Salhani D: Beam characteristics of the Therapax DXT300 orthovoltage therapy unit. Phys Med Biol, 39: 1377-1392, 1994.
    • (1994) Phys Med Biol , vol.39 , pp. 1377-1392
    • Gregig, L.1    Soubra, M.2    Salhani, D.3
  • 17
    • 25344477240 scopus 로고    scopus 로고
    • A quality control program in dermatological radiotherapy with external beam treatment units
    • Scielzo G, Gabriele P: A quality control program in dermatological radiotherapy with external beam treatment units. JEADV, 14: S141, 2000.
    • (2000) JEADV , vol.14
    • Scielzo, G.1    Gabriele, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.