메뉴 건너뛰기




Volumn 20, Issue 4, 2002, Pages 169-179

Routine MR imaging protocol with breath-hold fast scans: Diagnostic efficacy for focal liver lesions

Author keywords

Contrast media, gadolinium; Liver, neoplasm; Magnetic resonance, diagnosis; Magnetic resonance, fast scan

Indexed keywords

GADODIAMIDE; GADOLINIUM PENTETATE;

EID: 0036657153     PISSN: 02882043     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (19)
  • 1
    • 0027509489 scopus 로고
    • Fast multiplanar spoiled gradient-recalled imaging of the liver: Pulse sequence optimization and comparison with spin-echo MR imaging
    • Low RN, Francis IR, Herfkens RJ, et al. Fast multiplanar spoiled gradient-recalled imaging of the liver: pulse sequence optimization and comparison with spin-echo MR imaging. AJR Am J Roentgenol, 160: 501-509, 1993.
    • (1993) AJR Am J Roentgenol , vol.160 , pp. 501-509
    • Low, R.N.1    Francis, I.R.2    Herfkens, R.J.3
  • 2
    • 0029953063 scopus 로고    scopus 로고
    • Liver masses: Replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging
    • Gaa J, Hatabu H, Jenkins RL, Finn JP, Edelman RR. Liver masses: replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging. Radiology, 200: 459-464, 1996.
    • (1996) Radiology , vol.200 , pp. 459-464
    • Gaa, J.1    Hatabu, H.2    Jenkins, R.L.3    Finn, J.P.4    Edelman, R.R.5
  • 3
    • 0031001798 scopus 로고    scopus 로고
    • Liver T2-weighted MR imaging: Comparison of fast and conventional half-Fourier single-shot turbo spin-echo, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences
    • Tang Y, Yamashita Y, Namimoto T, Abe Y, Takahashi M. Liver T2-weighted MR imaging: comparison of fast and conventional half-Fourier single-shot turbo spin-echo, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences. Radiology, 203: 766-772, 1997.
    • (1997) Radiology , vol.203 , pp. 766-772
    • Tang, Y.1    Yamashita, Y.2    Namimoto, T.3    Abe, Y.4    Takahashi, M.5
  • 4
    • 0030943691 scopus 로고    scopus 로고
    • Non-breath-hold fast spin-echo versus breath-hold fast spin-echo and spoiled gradient-recalled echo MR imaging in the detection of hepatic tumors: Correlation with surgical findings
    • Soyer P, Gouhiri M, Rondeau Y, Mosnier H, Scherrer A. Non-breath-hold fast spin-echo versus breath-hold fast spin-echo and spoiled gradient-recalled echo MR imaging in the detection of hepatic tumors: correlation with surgical findings. AJR Am J Roentgenol, 168: 1199-1204, 1997.
    • (1997) AJR Am J Roentgenol , vol.168 , pp. 1199-1204
    • Soyer, P.1    Gouhiri, M.2    Rondeau, Y.3    Mosnier, H.4    Scherrer, A.5
  • 5
    • 0029851612 scopus 로고    scopus 로고
    • Focal liver lesions: Fast T2-weighted MR imaging with half-Fourier rapid acquisition with relaxation enhancement
    • Van Hoe L, Bosmans H, Aerts P, et al. Focal liver lesions: fast T2-weighted MR imaging with half-Fourier rapid acquisition with relaxation enhancement. Radiology, 201: 817-823, 1996.
    • (1996) Radiology , vol.201 , pp. 817-823
    • Van Hoe, L.1    Bosmans, H.2    Aerts, P.3
  • 6
    • 0025269074 scopus 로고
    • Free-response methodology: Alternate analysis and a new observer-performance experiment
    • Chakraborty DP, Winter LH. Free-response methodology: alternate analysis and a new observer-performance experiment. Radiology, 174: 873-881, 1990.
    • (1990) Radiology , vol.174 , pp. 873-881
    • Chakraborty, D.P.1    Winter, L.H.2
  • 7
    • 0024462154 scopus 로고
    • Maximum likelihood analysis of free-response receiver operating characteristic (FROC) data
    • Chakraborty DP. Maximum likelihood analysis of free-response receiver operating characteristic (FROC) data. Med Phys, 16: 561-568, 1989.
    • (1989) Med Phys , vol.16 , pp. 561-568
    • Chakraborty, D.P.1
  • 8
    • 0027957235 scopus 로고
    • Abdominal MR imaging: Evaluation of a fast spin echo sequence
    • Outwater EK, Mitchell DG, Vinitski S. Abdominal MR imaging: evaluation of a fast spin echo sequence, Radiology, 190: 425-429, 1994.
    • (1994) Radiology , vol.190 , pp. 425-429
    • Outwater, E.K.1    Mitchell, D.G.2    Vinitski, S.3
  • 9
    • 0031882612 scopus 로고    scopus 로고
    • Focal hepatic lesion detection: Comparison of four T2-weighted MR imaging sequences
    • Kanematsu M, Hoshi H, Murakami T, et al. Focal hepatic lesion detection: comparison of four T2-weighted MR imaging sequences. Radiology, 206: 167-175, 1998.
    • (1998) Radiology , vol.206 , pp. 167-175
    • Kanematsu, M.1    Hoshi, H.2    Murakami, T.3
  • 10
    • 0031835935 scopus 로고    scopus 로고
    • Hepatic T2-weighted MRI: A prospective comparison of sequences, including breath-hold, half-Fourier turbo spin echo (HASTE)
    • Coates GG, Borrello JA, McFarland EG, Mirowitz SA, Brown JJ. Hepatic T2-weighted MRI: a prospective comparison of sequences, including breath-hold, half-Fourier turbo spin echo (HASTE). J Magn Reson Imaging, 8: 642-649, 1998.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 642-649
    • Coates, G.G.1    Borrello, J.A.2    McFarland, E.G.3    Mirowitz, S.A.4    Brown, J.J.5
  • 11
    • 0344474664 scopus 로고    scopus 로고
    • Comparison of multishot turbo spin echo and HASTE sequences for T2-weighted MRI of liver lesions
    • Yu JS, Kim KW, Kim YH, Jeong EK, Chien D. Comparison of multishot turbo spin echo and HASTE sequences for T2-weighted MRI of liver lesions. J Magn Reson Imaging, 8: 1079-1084, 1998.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 1079-1084
    • Yu, J.S.1    Kim, K.W.2    Kim, Y.H.3    Jeong, E.K.4    Chien, D.5
  • 12
    • 0030820223 scopus 로고    scopus 로고
    • Hepatic lesions: Discrimination of nonsolid, benign lesions from solid, malignant lesions with heavily T2-weighted fast spin-echo MR imaging
    • Ito K, Mitchell DG, Outwater EK, Szklaruk J, Sadek AG. Hepatic lesions: discrimination of nonsolid, benign lesions from solid, malignant lesions with heavily T2-weighted fast spin-echo MR imaging. Radiology, 204: 729-737, 1997.
    • (1997) Radiology , vol.204 , pp. 729-737
    • Ito, K.1    Mitchell, D.G.2    Outwater, E.K.3    Szklaruk, J.4    Sadek, A.G.5
  • 13
    • 0030033316 scopus 로고    scopus 로고
    • Dynamic MR imaging and early-phase helical CT for detecting small intrahepatic metastases of hepatocellular carcinoma
    • Oi H, Murakami T, Kim T, Matsushita M, Kishimoto H, Nakamura H. Dynamic MR imaging and early-phase helical CT for detecting small intrahepatic metastases of hepatocellular carcinoma. AJR Am J Roentgenol, 166: 369-374, 1996.
    • (1996) AJR Am J Roentgenol , vol.166 , pp. 369-374
    • Oi, H.1    Murakami, T.2    Kim, T.3    Matsushita, M.4    Kishimoto, H.5    Nakamura, H.6
  • 14
    • 0033008011 scopus 로고    scopus 로고
    • Detection of hepatocellular carcinoma: Comparison of T2-weighted breath-hold fast spin-echo sequences and high-resolution dynamic MR imaging with a phased-array body coil
    • Fujita T, Ito K, Honjo K, Okazaki H, Matsumoto T, Matsunaga N. Detection of hepatocellular carcinoma: comparison of T2-weighted breath-hold fast spin-echo sequences and high-resolution dynamic MR imaging with a phased-array body coil. J Magn Reson Imaging, 9: 274-279, 1999.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 274-279
    • Fujita, T.1    Ito, K.2    Honjo, K.3    Okazaki, H.4    Matsumoto, T.5    Matsunaga, N.6
  • 15
    • 0030043691 scopus 로고    scopus 로고
    • Fatty tissue on out-of-phase MR images: Paradoxical suppression of signal intensity by paramagnetic contrast agents
    • Mitchell DG, Stolpen AH, Siegelman ES, Bolinger L, Outwater EK. Fatty tissue on out-of-phase MR images: paradoxical suppression of signal intensity by paramagnetic contrast agents. Radiology, 198: 351-357, 1996.
    • (1996) Radiology , vol.198 , pp. 351-357
    • Mitchell, D.G.1    Stolpen, A.H.2    Siegelman, E.S.3    Bolinger, L.4    Outwater, E.K.5
  • 17
    • 0029045556 scopus 로고
    • Magnetic resonance imaging in the detection of focal liver lesions: Comparison of dynamic contrast-enhanced TurboFLASH and T2-weighted spin-echo images
    • Ward J, Baudouin CJ, Ridgway JP, Robinson PJ. Magnetic resonance imaging in the detection of focal liver lesions: comparison of dynamic contrast-enhanced TurboFLASH and T2-weighted spin-echo images. Br J Radiol, 68: 463-470, 1995.
    • (1995) Br J Radiol , vol.68 , pp. 463-470
    • Ward, J.1    Baudouin, C.J.2    Ridgway, J.P.3    Robinson, P.J.4
  • 18
    • 0032935493 scopus 로고    scopus 로고
    • Evaluation of a 10-minute comprehensive MR imaging examination of the upper abdomen
    • Semelka RC, Balci NC, de Beeck BO, Reinhold C. Evaluation of a 10-minute comprehensive MR imaging examination of the upper abdomen. Radiology, 211: 189-195, 1999.
    • (1999) Radiology , vol.211 , pp. 189-195
    • Semelka, R.C.1    Balci, N.C.2    De Beeck, B.O.3    Reinhold, C.4
  • 19
    • 0035142169 scopus 로고    scopus 로고
    • Dynamic contrast-enhanced three-dimensional MR imaging of liver parenchyma: Source images and angiographic reconstructions to define hepatic arterial anatomy
    • Lavelle MT, Lee VS, Rofsky NM, Krinsky GA, Weinreb JC. Dynamic contrast-enhanced three-dimensional MR imaging of liver parenchyma: source images and angiographic reconstructions to define hepatic arterial anatomy. Radiology, 218: 389-394, 2001.
    • (2001) Radiology , vol.218 , pp. 389-394
    • Lavelle, M.T.1    Lee, V.S.2    Rofsky, N.M.3    Krinsky, G.A.4    Weinreb, J.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.