Volumn 35, Issue 5, 2002, Pages 279-286

Acoustic microscopy measurement of elastic constants by using an optimization method on measured and calculated SAW velocities: Effect of initial cij values on the calculation convergence and influence of the LFI transducer parameters on the determination of the SAW velocity

Author keywords

Anisotropic solids; Elastic constants; Line focus acoustic microscopy; Simplex method; Surface acoustic wave velocity

Indexed keywords

ACOUSTIC MICROSCOPES; ACOUSTIC TRANSDUCERS; ACOUSTIC WAVE PROPAGATION; ACOUSTIC WAVE VELOCITY; ANISOTROPY; CRYSTALLINE MATERIALS; OPTIMIZATION; TIN;

EID: 0036643106     PISSN: 09638695     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0963-8695(01)00051-2     Document Type: Article
Times cited : (13)

References (14)
  • 7
    • 0032643322 scopus 로고    scopus 로고
    • Determination of elastic constants of composites by time-resolved acoustic microscopy
    • (1999) Ultrasonics , vol.37 , Issue.4 , pp. 283-289
    • Wang, L.1
  • 9
    • 0002358126 scopus 로고
    • Elastic wave reflection from liquid-anisotropic substrate interfaces
    • (1991) Wave Motion , vol.14 , pp. 55-67
    • Nayfeh, A.H.1