메뉴 건너뛰기




Volumn 50, Issue 7, 2002, Pages 298-301

Total Aortic Arch Aneurysm Repair using a Stent Graft without Cardiac or Cerebral Ischemia

Author keywords

Aortic arch aneurysm; Ischemia; Near infrared oxymetry; Stent graft

Indexed keywords

AGED; ANASTOMOSIS; ANEURYSM SURGERY; AORTA ARCH ANOMALY; AORTA CLAMPING; AORTA DISSECTION; AORTIC ARCH ANEURYSM REPAIR; ASCENDING AORTA; ATHEROMATOSIS; BRAIN ISCHEMIA; BRAIN PERFUSION; CARDIOPULMONARY BYPASS; CASE REPORT; CONFERENCE PAPER; HEART MUSCLE ISCHEMIA; HIGH RISK PATIENT; HUMAN; INDUCED HYPOTHERMIA; MALE; NEAR INFRARED OXYMETRY; OXIMETRY; PATIENT MONITORING; STENT; SURGICAL TECHNIQUE; TREATMENT INDICATION; AORTA; ARTICLE; DISSECTING ANEURYSM; HEART SURGERY; METHODOLOGY; NEAR INFRARED SPECTROSCOPY; THORACIC AORTA ANEURYSM; VASCULAR PATENCY; VASCULAR SURGERY;

EID: 0036632944     PISSN: 13444964     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03032299     Document Type: Conference Paper
Times cited : (7)

References (4)
  • 1
    • 4243631207 scopus 로고    scopus 로고
    • New graft-implanting method for thoracic aortic aneurysm or dissection with a stented graft
    • Kato M, Ohnishi K, Kaneko M, Ueda T, Kishi D, Mizushima T, et al. New graft-implanting method for thoracic aortic aneurysm or dissection with a stented graft. Circulation 1996; 94 (Suppl II): 188-93.
    • (1996) Circulation , vol.94 , Issue.SUPPL. II , pp. 188-193
    • Kato, M.1    Ohnishi, K.2    Kaneko, M.3    Ueda, T.4    Kishi, D.5    Mizushima, T.6
  • 2
    • 0032907831 scopus 로고    scopus 로고
    • New operative method for distal aortic arch aneurysm: Combined cervical branch bypass and endovascular stent-graft implantation
    • Kato M, Kaneko M, Kuratani T, Horiguchi K, Ikushima H, Ohnishi K. New operative method for distal aortic arch aneurysm: combined cervical branch bypass and endovascular stent-graft implantation. J Thorac Cardiovasc Surg 1999; 117: 832-4.
    • (1999) J Thorac Cardiovasc Surg , vol.117 , pp. 832-834
    • Kato, M.1    Kaneko, M.2    Kuratani, T.3    Horiguchi, K.4    Ikushima, H.5    Ohnishi, K.6
  • 3
    • 0032175932 scopus 로고    scopus 로고
    • Clinical results of endovascular stent graft repair for fifty cases of thoracic aortic aneurysms
    • Kawaguchi S, Ishimaru S, Shimazaki T, Yokoi Y, Koizumi N, Obitsu Y, et al. Clinical results of endovascular stent graft repair for fifty cases of thoracic aortic aneurysms (Eng abstr). J Jpn Assn Thorac Surg 1998; 46: 971-5.
    • (1998) J Jpn Assn Thorac Surg , vol.46 , pp. 971-975
    • Kawaguchi, S.1    Ishimaru, S.2    Shimazaki, T.3    Yokoi, Y.4    Koizumi, N.5    Obitsu, Y.6
  • 4
    • 0842277571 scopus 로고    scopus 로고
    • Monitoring oxyhemoglobin levels in the brain using a near-infrared oxygen monitor during selective cerebral perfusion
    • Kawashima Y, Takamoto S, ed. Amsterdam: Elsevier Science
    • Ueda T, Ito T, Goto T, Mitsumaru A, Yozu R, Kawada S. Monitoring oxyhemoglobin levels in the brain using a near-infrared oxygen monitor during selective cerebral perfusion. In: Kawashima Y, Takamoto S, ed. Brain protection in aortic surgery. Amsterdam: Elsevier Science, 1997: 91-6.
    • (1997) Brain Protection in Aortic Surgery , pp. 91-96
    • Ueda, T.1    Ito, T.2    Goto, T.3    Mitsumaru, A.4    Yozu, R.5    Kawada, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.