-
1
-
-
0022701703
-
Maxillary sinus implant reconstructions
-
Tatum H. Maxillary sinus implant reconstructions. Dent Clin North Am 1986;30: 207-229.
-
(1986)
Dent Clin North Am
, vol.30
, pp. 207-229
-
-
Tatum, H.1
-
2
-
-
0019197813
-
Grafting of maxillary sinus floor with autogenous marrow and bone
-
Boyne P, James RA. Grafting of maxillary sinus floor with autogenous marrow and bone. J Oral Surg 1980;38:613-616.
-
(1980)
J Oral Surg
, vol.38
, pp. 613-616
-
-
Boyne, P.1
James, R.A.2
-
3
-
-
0023499767
-
Chemical implant fixation using hydroxyapatite coatings
-
Geesink RGT, De Groot K, Klein CPAT. Chemical implant fixation using hydroxyapatite coatings. Clin Orthop 1987;225: 147-170.
-
(1987)
Clin Orthop
, vol.225
, pp. 147-170
-
-
Geesink, R.G.T.1
De Groot, K.2
Klein, C.P.A.T.3
-
4
-
-
0023688524
-
Hydroxyapatite-coated titanium for orthopaedic implant applications
-
Cook SD, Thomas KA, Kay JF, Jarcho M. Hydroxyapatite-coated titanium for orthopaedic implant applications. Clin Orthop 1988;232:225-243.
-
(1988)
Clin Orthop
, vol.232
, pp. 225-243
-
-
Cook, S.D.1
Thomas, K.A.2
Kay, J.F.3
Jarcho, M.4
-
5
-
-
0025900565
-
Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs
-
Buser D, Schenk RK, Steinemann S, Fiorellini JP, Fox CH, Stich H. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mater Res 1991;25:889-902.
-
(1991)
J Biomed Mater Res
, vol.25
, pp. 889-902
-
-
Buser, D.1
Schenk, R.K.2
Steinemann, S.3
Fiorellini, J.P.4
Fox, C.H.5
Stich, H.6
-
6
-
-
0027022484
-
Histomorphometry of bone apposition around three types of endosseous dental implants
-
Weinlaender M, Kenney EB, Lekovic V, Beumer J, Moy PK, Lewis S. Histomorphometry of bone apposition around three types of endosseous dental implants. Int J Oral Maxillofac Implants 1992;7:491-496.
-
(1992)
Int J Oral Maxillofac Implants
, vol.7
, pp. 491-496
-
-
Weinlaender, M.1
Kenney, E.B.2
Lekovic, V.3
Beumer, J.4
Moy, P.K.5
Lewis, S.6
-
7
-
-
0027604298
-
Histologic investigation of the biologic behavior of different hydroxyapatite plasma-sprayed coatings in rabbits
-
Jansen JA, van der Waerden JP, Wolke JG. Histologic investigation of the biologic behavior of different hydroxyapatite plasma-sprayed coatings in rabbits. J Biomed Mater Res 1993;27:603-610.
-
(1993)
J Biomed Mater Res
, vol.27
, pp. 603-610
-
-
Jansen, J.A.1
Van Der Waerden, J.P.2
Wolke, J.G.3
-
8
-
-
0028057227
-
Long-term in vivo study of plasma-sprayed coatings on titanium alloys of tetracalciumphosphate, hydroxyapatite and alpha-tricalciumphosphate
-
Klein CPAT, Patka P, Wolke JG, de Blieck-Hogervorst JMA, de Groot K. Long-term in vivo study of plasma-sprayed coatings on titanium alloys of tetracalciumphosphate, hydroxyapatite and alpha-tricalciumphosphate. Biomaterials 1994;15:146-150.
-
(1994)
Biomaterials
, vol.15
, pp. 146-150
-
-
Klein, C.P.A.T.1
Patka, P.2
Wolke, J.G.3
De Blieck-Hogervorst, J.M.A.4
De Groot, K.5
-
9
-
-
0031127109
-
A histological and histomorphometrical evaluation of the application of screw designed calcium phosphate (Ca-P) coated implants in the cancellous maxillary bone of the goat
-
Caulier H, van der Waerden JP, Wolke JG, Kalk W, Naert I, Jansen JA. A histological and histomorphometrical evaluation of the application of screw designed calcium phosphate (Ca-P) coated implants in the cancellous maxillary bone of the goat. J Biomed Mater Res 1997;35:19-30.
-
(1997)
J Biomed Mater Res
, vol.35
, pp. 19-30
-
-
Caulier, H.1
Van Der Waerden, J.P.2
Wolke, J.G.3
Kalk, W.4
Naert, I.5
Jansen, J.A.6
-
10
-
-
0032135409
-
Bone healing capacity of titanium plasma-sprayed and hydroxylapatite-coated oral implants
-
Vercaigne S, Wolke JG, Naert I, Jansen JA. Bone healing capacity of titanium plasma-sprayed and hydroxylapatite-coated oral implants. Clin Oral Implants Res 1998;9:261-271.
-
(1998)
Clin Oral Implants Res
, vol.9
, pp. 261-271
-
-
Vercaigne, S.1
Wolke, J.G.2
Naert, I.3
Jansen, J.A.4
-
11
-
-
0030144537
-
Eight-year clinical retrospective study of titanium plasma-sprayed and hydroxyapatite-coated cylinder implants
-
Wheeler SL. Eight-year clinical retrospective study of titanium plasma-sprayed and hydroxyapatite-coated cylinder implants. Int J Oral Maxillofac Implants 1996;11:340-350.
-
(1996)
Int J Oral Maxillofac Implants
, vol.11
, pp. 340-350
-
-
Wheeler, S.L.1
-
12
-
-
0032200352
-
A 3- To 6-year study of overdentures supported by hydroxyapatite-coated endosseous dental implants
-
Watson CJ, Ogden AR, Tinsley D, Russel JL, Davidson EM. A 3-to 6-year study of overdentures supported by hydroxyapatite-coated endosseous dental implants. Int J Prosthodont 1998;11:610-619.
-
(1998)
Int J Prosthodont
, vol.11
, pp. 610-619
-
-
Watson, C.J.1
Ogden, A.R.2
Tinsley, D.3
Russel, J.L.4
Davidson, E.M.5
-
13
-
-
1542265433
-
Treatment planning for the edentulous maxillary posterior region
-
St Louis: Mosby Year Book
-
Misch CE. Treatment planning for the edentulous maxillary posterior region. In: Contemporary Implant Dentistry. St Louis: Mosby Year Book, 1987:241-255.
-
(1987)
Contemporary Implant Dentistry
, pp. 241-255
-
-
Misch, C.E.1
-
14
-
-
84983897712
-
Clinical results and guidelines in Steri-Oss endosseous implants
-
Saadoun AP, Le Gall ML. Clinical results and guidelines in Steri-Oss endosseous implants. Int J Periodontics Restorative Dent 1992;12:487-499.
-
(1992)
Int J Periodontics Restorative Dent
, vol.12
, pp. 487-499
-
-
Saadoun, A.P.1
Le Gall, M.L.2
-
15
-
-
0025453290
-
Biointegrated hydroxylapatite-coated dental implants: 5 year clinical observations
-
Kent JN, Block MS, Finger IM, Guerra L, Larsen H, Misiek DJ. Biointegrated hydroxylapatite-coated dental implants: 5 year clinical observations. J Am Dent Assoc 1990;121:138-144.
-
(1990)
J Am Dent Assoc
, vol.121
, pp. 138-144
-
-
Kent, J.N.1
Block, M.S.2
Finger, I.M.3
Guerra, L.4
Larsen, H.5
Misiek, D.J.6
-
16
-
-
0028074972
-
Long-term follow-up on hydroxylapatite-coated cylindrical dental implants: A comparison between development and recent periods
-
Block M, Kent JN. Long-term follow-up on hydroxylapatite-coated cylindrical dental implants: A comparison between development and recent periods. Int J Oral Maxillofac Surg 1994;52:937-943.
-
(1994)
Int J Oral Maxillofac Surg
, vol.52
, pp. 937-943
-
-
Block, M.1
Kent, J.N.2
-
17
-
-
0027353784
-
Five-year statistical and clinical observations with the IMZ two-stage osseointegrated implant system
-
Babbush CA, Shimura M. Five-year statistical and clinical observations with the IMZ two-stage osseointegrated implant system. Int J Oral Maxillofac Implants 1993;8:245-253.
-
(1993)
Int J Oral Maxillofac Implants
, vol.8
, pp. 245-253
-
-
Babbush, C.A.1
Shimura, M.2
-
18
-
-
0038243974
-
The application of HA-coated dental implants in patients with severe bone defects
-
Andersson ÖH, Yli-Urpo A (eds) London: Butterworth-Heinemann
-
De Lange GL, Kuiper L, Blijdorp PA. The application of HA-coated dental implants in patients with severe bone defects. In: Andersson ÖH, Yli-Urpo A (eds). Bioceramics, vol 7. London: Butterworth-Heinemann, 1994:430-434.
-
(1994)
Bioceramics
, vol.7
, pp. 430-434
-
-
De Lange, G.L.1
Kuiper, L.2
Blijdorp, P.A.3
-
19
-
-
0031244133
-
Short- And long-term animal studies with plasma-sprayed calcium phosphate-coated implants
-
Gottlander M, Johansson CB, Albrektsson T. Short-and long-term animal studies with plasma-sprayed calcium phosphate-coated implants. Clin Oral Implants Res 1997;8:345-351.
-
(1997)
Clin Oral Implants Res
, vol.8
, pp. 345-351
-
-
Gottlander, M.1
Johansson, C.B.2
Albrektsson, T.3
-
20
-
-
0028414098
-
Histological observations of coated and prestressed dental implants under flexible or rigid loading conditions
-
Hong L, Klein CPAT, De Groot K. Histological observations of coated and prestressed dental implants under flexible or rigid loading conditions. Biomaterials 1994;15:390-395.
-
(1994)
Biomaterials
, vol.15
, pp. 390-395
-
-
Hong, L.1
Klein, C.P.A.T.2
De Groot, K.3
-
21
-
-
0024518642
-
Interface between bone and implants of solid hydroxylapatite or hydroxylapatite coated titanium implants
-
De Lange GL, Donath K. Interface between bone and implants of solid hydroxylapatite or hydroxylapatite coated titanium implants. Biomaterials 1989;10-.121-125.
-
(1989)
Biomaterials
, vol.10
, pp. 121-125
-
-
De Lange, G.L.1
Donath, K.2
-
22
-
-
51649146401
-
Studies on the thermal spraying of apatite bioceramics
-
Wolke JG, de Blieck-Hogervorst JMA, Dhert WJA, Klein CPAT, De Groot K. Studies on the thermal spraying of apatite bioceramics. J Thermal Spray Technol 1992;1:75-82.
-
(1992)
J Thermal Spray Technol
, vol.1
, pp. 75-82
-
-
Wolke, J.G.1
De Blieck-Hogervorst, J.M.A.2
Dhert, W.J.A.3
Klein, C.P.A.T.4
De Groot, K.5
-
23
-
-
0003046623
-
Calcium phosphates in oral biology and medicine
-
Meyers HM (ed) Basel, Switzerland: Karger
-
LeGeros RL. Calcium phosphates in oral biology and medicine. In: Meyers HM (ed). Monographs in Oral Science. Basel, Switzerland: Karger, 1991:154-171.
-
(1991)
Monographs in Oral Science
, pp. 154-171
-
-
LeGeros, R.L.1
-
24
-
-
0030932204
-
Effects of hydroxyapatite particles on periodontal ligament fibroblast-like cell behavior
-
Alliot-Licht B, De Lange GL, Grégoire M. Effects of hydroxyapatite particles on periodontal ligament fibroblast-like cell behavior. J Periodontol 1997;68:158-165.
-
(1997)
J Periodontol
, vol.68
, pp. 158-165
-
-
Alliot-Licht, B.1
De Lange, G.L.2
Grégoire, M.3
-
25
-
-
0033089291
-
Bone-hydroxyapatite interface in retrieved hydroxyapatite-coated titanium implants: A clinical and histologic report
-
Piattelli A, Scarano A, Di Alberti L, Piattelli M. Bone-hydroxyapatite interface in retrieved hydroxyapatite-coated titanium implants: A clinical and histologic report. Int J Oral Maxillofac Implants 1999;14: 233-238.
-
(1999)
Int J Oral Maxillofac Implants
, vol.14
, pp. 233-238
-
-
Piattelli, A.1
Scarano, A.2
Di Alberti, L.3
Piattelli, M.4
-
26
-
-
0034252926
-
Histological observations on biopsies harvested following sinus floor elevation using a bioactive glass material of narrow size range
-
Tadjoedin ES, De Lange GL, Holzmann P, Kuiper L, Burger EH. Histological observations on biopsies harvested following sinus floor elevation using a bioactive glass material of narrow size range. Clin Oral Implants Res 2000;11:334-344.
-
(2000)
Clin Oral Implants Res
, vol.11
, pp. 334-344
-
-
Tadjoedin, E.S.1
De Lange, G.L.2
Holzmann, P.3
Kuiper, L.4
Burger, E.H.5
-
27
-
-
0033113160
-
Clinical outcome of screw vent implants. A 7-year prospective follow-up study
-
De Bruyn H, Colaert B, Lindén U, Johansson C, Albrektsson T. Clinical outcome of screw vent implants. A 7-year prospective follow-up study. Clin Oral Implants Res 1999;10:139-148.
-
(1999)
Clin Oral Implants Res
, vol.10
, pp. 139-148
-
-
De Bruyn, H.1
Colaert, B.2
Lindén, U.3
Johansson, C.4
Albrektsson, T.5
|