Photoelastic and thermoelastic measurement of stress on the proximal femur before and after implantation of a hip prosthesis with retention of the femoral neck

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BIOMECHANICS; CADAVER; CONTROLLED STUDY; ELASTICITY; FEMUR; FEMUR NECK; FORCE TRANSDUCER; FROZEN SECTION; HIP PROSTHESIS; HUMAN; HUMAN TISSUE; IMPLANTATION; LOAD CARRYING CAPACITY; POSTOPERATIVE PERIOD; PREOPERATIVE EVALUATION; RELIABILITY; SENSITIVITY ANALYSIS; STRESS; SURGICAL TECHNIQUE; WEIGHT BEARING;

EID: 0036590572     PISSN: 01477447     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (72)
  • 2
    • 0012682752 scopus 로고
    • Effect of repeated loading on torsional fixation of cementless total hip femoral components
    • Arima J, McCarty D, White SE, Whiteside MD. Effect of repeated loading on torsional fixation of cementless total hip femoral components. Orthopeadic Transactions. 1994; 17:1117.
    • (1994) Orthopeadic Transactions , vol.17 , pp. 1117
    • Arima, J.1    McCarty, D.2    White, S.E.3    Whiteside, M.D.4
  • 3
    • 0012634531 scopus 로고
    • Rotational stability of non-cemented total hip femoral components
    • McCarthy DS, Whiteside LA, Rotational stability of non-cemented total hip femoral components. Orthopaedic Transactions. 1994; 17:1110.
    • (1994) Orthopaedic Transactions , vol.17 , pp. 1110
    • McCarthy, D.S.1    Whiteside, L.A.2
  • 4
    • 0024591258 scopus 로고
    • Torsional stability of the femoral component of hip arthroplasty. Response to an anterriorly applied load
    • Nunn D, Freeman MA, Tanner KE, Bonfield W. Torsional stability of the femoral component of hip arthroplasty. Response to an anterriorly applied load. J Bone Joint Surg Am. 1989; 71:452-455.
    • (1989) J. Bone Joint Surg. Am. , vol.71 , pp. 452-455
    • Nunn, D.1    Freeman, M.A.2    Tanner, K.E.3    Bonfield, W.4
  • 5
    • 0012679283 scopus 로고
    • Effect of retaining the femoral neck on torsional stability of the femoral component in total hip arthroplasty
    • White SE, McCarty DS, Whiteside LA. Effect of retaining the femoral neck on torsional stability of the femoral component in total hip arthroplasty. Orthopaedic Transactions. 1994; 17:1117.
    • (1994) Orthopaedic Transactions , vol.17 , pp. 1117
    • White, S.E.1    McCarty, D.S.2    Whiteside, L.A.3
  • 6
    • 0023901068 scopus 로고
    • Femoral neck retention in hip arthoplasty. A cadaver study of mechanical effects
    • Carlson L, Albrektsson B, Freeman MA. Femoral neck retention in hip arthoplasty. A cadaver study of mechanical effects. Acta Orthop Scand. 1988; 59:6-8.
    • (1988) Acta Orthop. Scand. , vol.59 , pp. 6-8
    • Carlson, L.1    Albrektsson, B.2    Freeman, M.A.3
  • 7
    • 0023819296 scopus 로고
    • The effect of drying and rewetting on some mechanical properties of cortical bone
    • Currey JD. The effect of drying and rewetting on some mechanical properties of cortical bone. J. Biomech. 1988; 21:439-441.
    • (1988) J. Biomech. , vol.21 , pp. 439-441
    • Currey, J.D.1
  • 9
    • 0012634202 scopus 로고
    • Photoelastic studies of bone forms
    • Milch H. Photoelastic studies of bone forms. J Bone Joint Surg Am. 1940; 22:621-626.
    • (1940) J. Bone Joint Surg. Am. , vol.22 , pp. 621-626
    • Milch, H.1
  • 10
    • 41149164285 scopus 로고
    • Über die bedeutung der bauprinzipien des stütz-und bewegungsapparates für die beanspruchung der röhrenknocken
    • Pauwels F. Über die bedeutung der bauprinzipien des stütz-und bewegungsapparates für die beanspruchung der röhrenknocken. Acta Anatomica. 1951; 12:207-227.
    • (1951) Acta Anatomica , vol.12 , pp. 207-227
    • Pauwels, F.1
  • 14
    • 0019415986 scopus 로고
    • In vivo strain measurements from bone and prosthesis folliwing total hip replacement. An experimental study in sheep
    • Lanyon LE, Paul IL, Rubin CT, et al. In vivo strain measurements from bone and prosthesis folliwing total hip replacement. An experimental study in sheep. J Bone Joint Surg Am. 1981; 63:989-1001.
    • (1981) J. Bone Joint Surg. Am. , vol.63 , pp. 989-1001
    • Lanyon, L.E.1    Paul, I.L.2    Rubin, C.T.3
  • 15
    • 0017837076 scopus 로고
    • Proximal strain distribution in the loaded femur. An in vitro comparison of the distributions in the intact femur and after insertion of different hip-replacement femoral components
    • Oh I, Harris WH. Proximal strain distribution in the loaded femur. An in vitro comparison of the distributions in the intact femur and after insertion of different hip-replacement femoral components. J Bone Joint Surg Am. 1978; 60:75-85.
    • (1978) J. Bone Joint Surg. Am. , vol.60 , pp. 75-85
    • Oh, I.1    Harris, W.H.2
  • 16
    • 0023161998 scopus 로고
    • Strains and micromotions of press-fit femoral stem prostheses
    • Walker PS, Schneeweis D, Murphy S, Nelson P. Strains and micromotions of press-fit femoral stem prostheses. J Biomech. 1987; 20:693-702.
    • (1987) J. Biomech. , vol.20 , pp. 693-702
    • Walker, P.S.1    Schneeweis, D.2    Murphy, S.3    Nelson, P.4
  • 17
    • 0020963921 scopus 로고
    • A survey of finite element analysis in orthopedic biomechanics: The first decade
    • Huiskes R, Chao EY. A survey of finite element analysis in orthopedic biomechanics: The first decade. J. Biomech. 1983; 16:385-409.
    • (1983) J. Biomech. , vol.16 , pp. 385-409
    • Huiskes, R.1    Chao, E.Y.2
  • 18
    • 0021064911 scopus 로고
    • Finite-element analysis and experimental investigation in a femur with hip endoprosthesis
    • Rohlmann A, Mossner U, Bergmann G, Kolbel R. Finite-element analysis and experimental investigation in a femur with hip endoprosthesis. J Biomech. 1983; 16:727-742.
    • (1983) J. Biomech. , vol.16 , pp. 727-742
    • Rohlmann, A.1    Mossner, U.2    Bergmann, G.3    Kolbel, R.4
  • 19
    • 0027641060 scopus 로고
    • Hip joint loading during walking and running, measured in two patients
    • Bergmann G, Graichen F, Rohlmann A. Hip joint loading during walking and running, measured in two patients. J Biomech. 1993; 26:969-990.
    • (1993) J. Biomech. , vol.26 , pp. 969-990
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 21
    • 0012724359 scopus 로고
    • Instruction Bulletins. Raleigh, NC: Measurements Groups Inc. Photolastic Division
    • Instruction Bulletins. Raleigh, NC: Measurements Groups Inc. Photolastic Division; 1982.
    • (1982)
  • 22
    • 0042836379 scopus 로고
    • Über die spezifische wärme fester körper insbesondere der metalle
    • Weber W. Über die spezifische wärme fester körper insbesondere der metalle. Poggendorfs Annalen der Physik. 1830; 20:177-213.
    • (1830) Poggendorfs Annalen Der Physik , vol.20 , pp. 177-213
    • Weber, W.1
  • 24
    • 0012633920 scopus 로고
    • Beschreibung des Meßsystems SPATE 9000 zur experimentellen Spannungs-analyse Diplomarbeit
    • BMW AG München
    • Backert D. Beschreibung des Meßsystems SPATE 9000 zur experimentellen Spannungs-analyse Diplomarbeit. BMW AG München; 1989.
    • (1989)
    • Backert, D.1
  • 25
    • 0004615512 scopus 로고
    • Infrared radiometric stress intrumentation application range study
    • NASA-Report CR-1067
    • Belgen MH. Infrared radiometric stress intrumentation application range study. NASA-Report CR-1067. 1967.
    • (1967)
    • Belgen, M.H.1
  • 26
    • 0002117118 scopus 로고
    • Structural stress management with an infrared radiometer
    • Belgen MH. Structural stress management with an infrared radiometer. ISA Transactions. 1967; 6:49-53.
    • (1967) ISA Transactions , vol.6 , pp. 49-53
    • Belgen, M.H.1
  • 27
    • 36849124387 scopus 로고
    • Thermoelasticity and reversible thermodynamics
    • Blot MA. Thermoelasticity and reversible thermodynamics. J Appl Phys. 1956; 27:240-253.
    • (1956) J. Appl. Phys. , vol.27 , pp. 240-253
    • Blot, M.A.1
  • 28
    • 0012635379 scopus 로고
    • Calibration and qualitative assessment of the Spate stress measurement system
    • East Kilbride, Glasgow: United Kingdom NEL Report No. 705
    • Harwood N, Cummings WM. Calibration and qualitative assessment of the Spate stress measurement system. East Kilbride, Glasgow: United Kingdom; 1986. NEL Report No. 705.
    • (1986)
    • Harwood, N.1    Cummings, W.M.2
  • 29
    • 0012635380 scopus 로고
    • Thermoelastische spannungsmessung
    • Rohrbach C, ed. Düsseldorf, Germany: VDI-Verlag
    • Oliver DE. Thermoelastische spannungsmessung. In: Rohrbach C, ed. Handbuch für Experimentelle Spannugnsanalyse. Düsseldorf, Germany: VDI-Verlag; 1989:630-640.
    • (1989) Handbuch Für Experimentelle Spannugnsanalyse , pp. 630-640
    • Oliver, D.E.1
  • 30
    • 0021624094 scopus 로고
    • Absolute calibration of the SPATE-technique for non-contacting stress measurement
    • Proceedings from the 5th International Congress on experimental mechanics. Montreal, Canada
    • Oliver DE, Webber JMD. Absolute calibration of the SPATE-technique for non-contacting stress measurement. Proceedings from the 5th International Congress on experimental mechanics. Montreal, Canada: 1984:539-546
    • (1984) , pp. 539-546
    • Oliver, D.E.1    Webber, J.M.D.2
  • 32
    • 0023089423 scopus 로고
    • Appraisal of a new infrared-based stress analysis technique
    • Stanley P. Appraisal of a new infrared-based stress analysis technique. Optical Engineering. 1987; 26:75-80.
    • (1987) Optical Engineering , vol.26 , pp. 75-80
    • Stanley, P.1
  • 33
    • 0012679207 scopus 로고
    • Optimierung der versuchsdurchführung bei der thermoelastischen spannungsanalyse
    • Woelfel HP, Feickert W, Steenhoff T. Optimierung der versuchsdurchführung bei der thermoelastischen spannungsanalyse. VDI-Berichte. 1991; 282:275-289.
    • (1991) VDI-Berichte , vol.282 , pp. 275-289
    • Woelfel, H.P.1    Feickert, W.2    Steenhoff, T.3
  • 34
    • 0012724360 scopus 로고
    • Stress analysis of complex structures using the thermoplastic effect
    • Cox LJ, Holbourn PE, Oliver DE, Webber JME. Stress analysis of complex structures using the thermoplastic effect. VDI-Berichte. 1982; 439:165-166.
    • (1982) VDI-Berichte , vol.439 , pp. 165-166
    • Cox, L.J.1    Holbourn, P.E.2    Oliver, D.E.3    Webber, J.M.E.4
  • 36
    • 0012741401 scopus 로고
    • SPATE 9000 Manual. London, England: Ometron Ltd
    • SPATE 9000 Manual. London, England: Ometron Ltd; 1990.
    • (1990)
  • 37
    • 4243576346 scopus 로고
    • Thermoelastic stress analysis of fresh bone
    • Paper presented: at the First International Conference of Stress Analysis by Thermoelastic Techniques (N.10) London, England
    • Duncan JL, Cummings WM. Thermoelastic stress analysis of fresh bone. Paper presented: at the First International Conference of Stress Analysis by Thermoelastic Techniques (N.10); 1984; London, England.
    • (1984)
    • Duncan, J.L.1    Cummings, W.M.2
  • 38
    • 28144446620 scopus 로고
    • A comparative study of stress distribution in human bone under simple and complex loading conditions and as modified by the insertion of a metallic prosthesis
    • Paper presented: at the International Conference of Stress and Vibration London, England
    • Duncan JL, MacKenzie A. A comparative study of stress distribution in human bone under simple and complex loading conditions and as modified by the insertion of a metallic prosthesis. Paper presented: at the International Conference of Stress and Vibration; 1989; London, England.
    • (1989)
    • Duncan, J.L.1    MacKenzie, A.2
  • 39
    • 0012679284 scopus 로고
    • Stress analysis of the pelvis by thermoelasticity
    • Bourgois R, Reymen L. Stress analysis of the pelvis by thermoelasticity. VDI-Berichte. 1986; 523-530.
    • (1986) VDI-Berichte , pp. 523-530
    • Bourgois, R.1    Reymen, L.2
  • 41
    • 84958486486 scopus 로고
    • Considerations of the surface temperature response to cyclic thermoelastic heat generation
    • McKelvie J. Considerations of the surface temperature response to cyclic thermoelastic heat generation. SPIE. 1987; 731:44-53.
    • (1987) SPIE , vol.731 , pp. 44-53
    • McKelvie, J.1
  • 42
    • 0012734112 scopus 로고
    • Primäre fixation und mikromotion zementfreier femur-schaft-prothesen
    • Hipp E, Gradinger R, Ascherl R, eds. Gräfelfing, Germany: Demeter Verlag
    • Gebauer D, Refior HJ, Haake M. Primäre fixation und mikromotion zementfreier femur-schaft-prothesen. In: Hipp E, Gradinger R, Ascherl R, eds. Die Zementlose Huftprothese. Gräfelfing, Germany: Demeter Verlag; 1992:68-71.
    • (1992) Die Zementlose Huftprothese , pp. 68-71
    • Gebauer, D.1    Refior, H.J.2    Haake, M.3
  • 43
    • 0001358392 scopus 로고
    • Strains and stresses in the upper femur studied by the stresscoat method
    • Kalen R. Strains and stresses in the upper femur studied by the stresscoat method. Acta Orthop Scand. 1961; 31:103-113.
    • (1961) Acta Orthop. Scand. , vol.31 , pp. 103-113
    • Kalen, R.1
  • 44
    • 0019126005 scopus 로고
    • The effect of calcar contact on femoral component micromovement. A mechanical study
    • Markolf KL, Amstutz HC, Hirschowitz DL. The effect of calcar contact on femoral component micromovement. A mechanical study. J Bone Joint Surg Am. 1980; 62:1315-1323.
    • (1980) J. Bone Joint Surg. Am. , vol.62 , pp. 1315-1323
    • Markolf, K.L.1    Amstutz, H.C.2    Hirschowitz, D.L.3
  • 45
    • 0023759917 scopus 로고
    • Design and fabrication of cementless hip stems
    • Walker PS, Robertson DD. Design and fabrication of cementless hip stems. Clin Orthop. 1988; 235:25-34.
    • (1988) Clin. Orthop. , vol.235 , pp. 25-34
    • Walker, P.S.1    Robertson, D.D.2
  • 46
    • 0014746120 scopus 로고
    • Abduction forces in the one-legged stance
    • McLeish RD, Charnley J. Abduction forces in the one-legged stance. J Biomech. 1970; 3:191-209.
    • (1970) J. Biomech. , vol.3 , pp. 191-209
    • McLeish, R.D.1    Charnley, J.2
  • 47
  • 48
    • 0027262466 scopus 로고
    • Forces acting on the juvenile hip joint in the one-legged stance
    • Heimkes B, Posel P, Plitz W, Jansson V. Forces acting on the juvenile hip joint in the one-legged stance. J Pediatr Orthop. 1993; 13:431-436.
    • (1993) J. Pediatr. Orthop. , vol.13 , pp. 431-436
    • Heimkes, B.1    Posel, P.2    Plitz, W.3    Jansson, V.4
  • 49
    • 0003835651 scopus 로고
    • Gesammelte Abhandlungen zur Funktionellen Anatomie des Bewegungsapparats
    • Berlin, Germany: Springer Verlag
    • Pauwels F. Gesammelte Abhandlungen zur Funktionellen Anatomie des Bewegungsapparats. Berlin, Germany: Springer Verlag; 1965.
    • (1965)
    • Pauwels, F.1
  • 50
    • 0023869835 scopus 로고
    • Telemetric force measurements across the hip after total arthroplasty
    • Davy DT, Kotzar GM, Brown RH, et al. Telemetric force measurements across the hip after total arthroplasty. J Bone Joint Surg Am. 1988; 70:45-50.
    • (1988) J. Bone Joint Surg. Am. , vol.70 , pp. 45-50
    • Davy, D.T.1    Kotzar, G.M.2    Brown, R.H.3
  • 51
    • 0012641843 scopus 로고
    • Comparison of strain patterns in femora implanted with straight and curved stem uncemented prostheses
    • Hipp E, Gradinger R, Ascherl R, eds. Huftprothese. Gräfelfing, Germany: Demeter Verlag
    • Glisson RR, Fulghum CS, Stranne SK, Fyda M, Seaber AV, Callaghan JJ. Comparison of strain patterns in femora implanted with straight and curved stem uncemented prostheses. In: Hipp E, Gradinger R, Ascherl R, eds. Die Zementlos. Huftprothese. Gräfelfing, Germany: Demeter Verlag; 1992:83-86.
    • (1992) Die Zementlos , pp. 83-86
    • Glisson, R.R.1    Fulghum, C.S.2    Stranne, S.K.3    Fyda, M.4    Seaber, A.V.5    Callaghan, J.J.6
  • 52
    • 0025266706 scopus 로고
    • Effect of press-fit femoral stems on strains in the femur. A photoelastic coating study
    • Zhou XM, Walker PS, Robertson DD. Effect of press-fit femoral stems on strains in the femur. A photoelastic coating study. J Arthroplasty. 1990; 5:71-82.
    • (1990) J. Arthroplasty , vol.5 , pp. 71-82
    • Zhou, X.M.1    Walker, P.S.2    Robertson, D.D.3
  • 53
    • 0012634205 scopus 로고
    • Darstellung der kraftubertragung prothese - knochen durch photoelastische beschichtung des proximalen femurs
    • Hipp E, Gradinger R, Ascherl R, eds. Gräfelfing, Germany: Demeter Verlag
    • Fulghum CS, Glisson RR, Callaghan JJ, Seaber AV, Ascherl R, Burgkart R. Darstellung der kraftubertragung prothese - knochen durch photoelastische beschichtung des proximalen femurs. In: Hipp E, Gradinger R, Ascherl R, eds. Die Zementlose Huftprothese. Gräfelfing, Germany: Demeter Verlag; 1992:81-82.
    • (1992) Die Zementlose Huftprothese , pp. 81-82
    • Fulghum, C.S.1    Glisson, R.R.2    Callaghan, J.J.3    Seaber, A.V.4    Ascherl, R.5    Burgkart, R.6
  • 55
    • 0014813258 scopus 로고
    • Determination of the modulus of elasticity of bone by a vibration method
    • Brash JL, Skorecki J. Determination of the modulus of elasticity of bone by a vibration method. Med Biol Eng. 1970; 8:389-393.
    • (1970) Med. Biol. Eng. , vol.8 , pp. 389-393
    • Brash, J.L.1    Skorecki, J.2
  • 56
    • 0012724363 scopus 로고
    • Experimental Studies of the Nonuniformity and Anisotropy of Human Compact Bone
    • [dissertation]. Stanford, Calif: Department of Materials Science and Engineering, Stanford University
    • Bundy K. Experimental Studies of the Nonuniformity and Anisotropy of Human Compact Bone [dissertation]. Stanford, Calif: Department of Materials Science and Engineering, Stanford University; 1974.
    • (1974)
    • Bundy, K.1
  • 57
    • 0019750790 scopus 로고
    • Materialkennwerte und festigkeitsverhalten des kompakten knochengewebes am coxalen human-femur
    • Knauss P. Materialkennwerte und festigkeitsverhalten des kompakten knochengewebes am coxalen human-femur. Biomed Tech (Berl). 1981; 26:311-315.
    • (1981) Biomed Tech (Berl) , vol.26 , pp. 311-315
    • Knauss, P.1
  • 58
    • 84958492489 scopus 로고
    • Stresses in vehicle chassis joints- a comparison of spate with another analysis techniques
    • Loader AJ, Turner WB, Harwood N. Stresses in vehicle chassis joints- a comparison of spate with another analysis techniques. SPIE. 1987; 731:148-153.
    • (1987) SPIE , vol.731 , pp. 148-153
    • Loader, A.J.1    Turner, W.B.2    Harwood, N.3
  • 59
    • 0022086003 scopus 로고
    • Quantitative stress analysis by means of the thermoelastic effect
    • Stanley P, Chan WK. Quantitative stress analysis by means of the thermoelastic effect. Journal of Strain Analysis. 1985; 20:129-137.
    • (1985) Journal of Strain Analysis , vol.20 , pp. 129-137
    • Stanley, P.1    Chan, W.K.2
  • 60
    • 0017092039 scopus 로고
    • Elastic properties of cortical bone in female humane femurs
    • Helfenstein U, Anliker M, Rüegegger P. Elastic properties of cortical bone in female humane femurs. J Biomech. 1976; 9:703-710.
    • (1976) J. Biomech. , vol.9 , pp. 703-710
    • Helfenstein, U.1    Anliker, M.2    Rüegegger, P.3
  • 61
    • 0003699786 scopus 로고
    • Eine Einführung in die Technik des Messens mit Dehnungsmeßstreifen
    • Darmstadt, Germany: Hottinger Baldwin Meß-technik GmbH
    • Hoffman K. Eine Einführung in die Technik des Messens mit Dehnungsmeßstreifen. Darmstadt, Germany: Hottinger Baldwin Meß-technik GmbH; 1987.
    • (1987)
    • Hoffman, K.1
  • 62
    • 0012685556 scopus 로고
    • Dehnungsmeßstreifen
    • Muller RK. Dehnungsmeßstreifen. VDI-BVV. 1980; 1164.
    • (1980) VDI-BVV , pp. 1164
    • Muller, R.K.1
  • 63
    • 0012637735 scopus 로고
    • Dehnungsmeßstreifen mit metallischem Meßgitter
    • Düsseldorf, Germany: VDI-Verlag
    • Rohrbach C. Dehnungsmeßstreifen mit metallischem Meßgitter. In: Handbuch fur Experimentelle Spannungsanalyse. Düsseldorf, Germany: VDI-Verlag; 1989:490-519.
    • (1989) Handbuch Fur Experimentelle Spannungsanalyse , pp. 490-519
    • Rohrbach, C.1
  • 64
    • 0018991457 scopus 로고
    • The influence of design parameters on calcar stress following femoral head arthroplasty
    • Cook SD, Klawitter JJ, Weinstein AM. The influence of design parameters on calcar stress following femoral head arthroplasty. J Biomed Mater Res. 1980; 14:133-144.
    • (1980) J. Biomed. Mater. Res. , vol.14 , pp. 133-144
    • Cook, S.D.1    Klawitter, J.J.2    Weinstein, A.M.3
  • 65
    • 0003386214 scopus 로고
    • Relativbewegungen und stress-shielding bei zementfreien hüftendoprothesen-eine analyse mit der methode der finite elemente
    • Hipp E, Gradinger R, Ascherl R, eds. Gräfelfing, Germany: Demeter Verlag
    • Gese H, Tensi HM, Ortloff S. Relativbewegungen und stress-shielding bei zementfreien hüftendoprothesen-eine analyse mit der methode der finite elemente. In: Hipp E, Gradinger R, Ascherl R, eds. Die Zementlose Huftprothese. Gräfelfing, Germany: Demeter Verlag; 1992:75-80.
    • (1992) Die Zementlose Huftprothese , pp. 75-80
    • Gese, H.1    Tensi, H.M.2    Ortloff, S.3
  • 66
    • 0012633747 scopus 로고
    • The relevance of stress computation in the femur with and without endoprostheses
    • Rohlmann A, Bergmann G, Kolbel R. The relevance of stress computation in the femur with and without endoprostheses. Finite Elements in Biomechanics. 1982; 361-377.
    • (1982) Finite Elements in Biomechanics , pp. 361-377
    • Rohlmann, A.1    Bergmann, G.2    Kolbel, R.3
  • 67
    • 0012641845 scopus 로고
    • Theoretical considerations for determining stress intensity factors via thermoelastic stress analysis
    • Pukas SR. Theoretical considerations for determining stress intensity factors via thermoelastic stress analysis. SPIE. 1987; 731:88-101.
    • (1987) SPIE , vol.731 , pp. 88-101
    • Pukas, S.R.1
  • 68
    • 0026812770 scopus 로고
    • Transmission of force to the trabecular structures of the proximal end of the femur
    • [German]
    • Elke R, Marugg S. Transmission of force to the trabecular structures of the proximal end of the femur [German]. Orthopade. 1992; 21:51-56.
    • (1992) Orthopade , vol.21 , pp. 51-56
    • Elke, R.1    Marugg, S.2
  • 69
    • 0000673438 scopus 로고
    • Regional differences in some of the physical properties of the human femur
    • Evans FG, Lebow M. Regional differences in some of the physical properties of the human femur. J Appl Physiol. 1950; 3:563-572.
    • (1950) J. Appl. Physiol. , vol.3 , pp. 563-572
    • Evans, F.G.1    Lebow, M.2
  • 70
    • 0012688812 scopus 로고
    • Messung der mikrobewegungen zwischen prothesenschaft und knochen bei huftgelenkersatz
    • Hipp E, Gradinger R, Ascherl R, eds. Gräfelfing, Germany: Demeter Verlag
    • Fulghum CS, Glisson RR, Callaghan JJ, Seaber AV, Ascherl R, Burgkart R. Messung der mikrobewegungen zwischen prothesenschaft und knochen bei huftgelenkersatz. In: Hipp E, Gradinger R, Ascherl R, eds. Die Zementlose Huftprothese. Gräfelfing, Germany: Demeter Verlag; 1992;62-63.
    • (1992) Die Zementlose Huftprothese , pp. 62-63
    • Fulghum, C.S.1    Glisson, R.R.2    Callaghan, J.J.3    Seaber, A.V.4    Ascherl, R.5    Burgkart, R.6
  • 71
    • 0028197667 scopus 로고
    • A new neck preserving total hip arthroplasty for the young patient
    • Krackow KA, Mont MA, Maar DC. A new neck preserving total hip arthroplasty for the young patient. Orthopedics. 1994; 17:253-259.
    • (1994) Orthopedics , vol.17 , pp. 253-259
    • Krackow, K.A.1    Mont, M.A.2    Maar, D.C.3
  • 72
    • 4243449634 scopus 로고
    • Biodynamic total hip prosthesis
    • Pipino F, Calderale PM. Biodynamic total hip prosthesis. Acta Orthop Belg. 1993; 59(suppl):S354-S355.
    • (1993) Acta Orthop. Belg. , vol.59 , Issue.SUPPL.
    • Pipino, F.1    Calderale, P.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.