메뉴 건너뛰기




Volumn 68, Issue 5, 2002, Pages 360-364

Closed versus open suctioning techniques

Author keywords

Intubation intratracheal; Pneumonia, bacterial, etiology; Respiration, artificial; Suction, instrumentation; Suction, methods; Ventilators, mechanical

Indexed keywords

ARTICLE; COST EFFECTIVENESS ANALYSIS; ENDOTRACHEAL TUBE; HUMAN; HYPOXEMIA; INFECTION; LUNG VOLUME; SUCTION; VENTILATOR ASSOCIATED PNEUMONIA; ARTIFICIAL VENTILATION; BACTERIAL PNEUMONIA; COMPARATIVE STUDY; METHODOLOGY; OXYGEN THERAPY; REVIEW;

EID: 0036580141     PISSN: 03759393     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (40)

References (16)
  • 1
    • 0025647269 scopus 로고
    • Incidence of colonization, nosocomial pneumonia, and mortality in critically ill patients using a Trach Care closed-suction system versus an open-suction system: Prospective, randomized study
    • Deppe SA, Kelly JW, Thoi LL, Chudy JH, Longfield RN, Ducey JP et al. Incidence of colonization, nosocomial pneumonia, and mortality in critically ill patients using a Trach Care closed-suction system versus an open-suction system: prospective, randomized study. Crit Care Med 1990;18:1389-93.
    • (1990) Crit Care Med , vol.18 , pp. 1389-1393
    • Deppe, S.A.1    Kelly, J.W.2    Thoi, L.L.3    Chudy, J.H.4    Longfield, R.N.5    Ducey, J.P.6
  • 2
    • 0022814488 scopus 로고
    • Contamination of a multiple-use suction catheter in a closed-circuit system compared to contamination of a disposable, single-use suction catheter
    • Ritz R, Scott LR, Coyle MB, Pierson DJ. Contamination of a multiple-use suction catheter in a closed-circuit system compared to contamination of a disposable, single-use suction catheter. Respir Care 1986;31:1086-91.
    • (1986) Respir Care , vol.31 , pp. 1086-1091
    • Ritz, R.1    Scott, L.R.2    Coyle, M.B.3    Pierson, D.J.4
  • 3
    • 0025992033 scopus 로고
    • Environmental contamination during tracheal suction
    • Cobley M, Atkins M, Jones PL. Environmental contamination during tracheal suction. Anaesthesia 1991;46:957-61.
    • (1991) Anaesthesia , vol.46 , pp. 957-961
    • Cobley, M.1    Atkins, M.2    Jones, P.L.3
  • 6
    • 0033852948 scopus 로고    scopus 로고
    • Nosocomial pneumonia in mechanically ventilated patients, a prospective randomised evaluation of the Stericath closed suctioning system
    • Combes P, Fauvage B, Oleyer C. Nosocomial pneumonia in mechanically ventilated patients, a prospective randomised evaluation of the Stericath closed suctioning system. Intensive Care Med 2000;26:878-82.
    • (2000) Intensive Care Med , vol.26 , pp. 878-882
    • Combes, P.1    Fauvage, B.2    Oleyer, C.3
  • 7
    • 0025471241 scopus 로고
    • Closed tracheal suction systems: Effectiveness and nursing implications
    • Noll ML, Hix CD, Scott G. Closed tracheal suction systems: effectiveness and nursing implications. AACN Clin Issues Crit Care Nurs 1990;1:318-28.
    • (1990) AACN Clin Issues Crit Care Nurs , vol.1 , pp. 318-328
    • Noll, M.L.1    Hix, C.D.2    Scott, G.3
  • 8
    • 0025940663 scopus 로고
    • An evaluation of the effectiveness of secretion removal with the Ballard closed-circuit suction catheter
    • Witmer MT, Hess D, Simmons M. An evaluation of the effectiveness of secretion removal with the Ballard closed-circuit suction catheter. Respir Care 1991;36:844-8.
    • (1991) Respir Care , vol.36 , pp. 844-848
    • Witmer, M.T.1    Hess, D.2    Simmons, M.3
  • 9
    • 0021713367 scopus 로고
    • Prevention of arterial oxygen desaturation during closed-airway endotracheal suction: Effect of ventilator mode
    • Craig KC, Benson MS, Pierson DJ. Prevention of arterial oxygen desaturation during closed-airway endotracheal suction: effect of ventilator mode. Respir Care 1984;29:1013-8.
    • (1984) Respir Care , vol.29 , pp. 1013-1018
    • Craig, K.C.1    Benson, M.S.2    Pierson, D.J.3
  • 10
    • 0023183788 scopus 로고
    • Evaluation of a closed-tracheal suction system
    • Carlon GC, Fox SJ, Ackerman NJ. Evaluation of a closed-tracheal suction system. Crit Care Med 1987;15:522-5.
    • (1987) Crit Care Med , vol.15 , pp. 522-525
    • Carlon, G.C.1    Fox, S.J.2    Ackerman, N.J.3
  • 11
    • 0024995695 scopus 로고
    • Effects of endotracheal suctioning on mixed venous oxygen saturation and heart rate in critically ill adults
    • Clark AP, Winslow EH, Tyler DO, White KM. Effects of endotracheal suctioning on mixed venous oxygen saturation and heart rate in critically ill adults. Heart Lung 1990;19:552-7.
    • (1990) Heart Lung , vol.19 , pp. 552-557
    • Clark, A.P.1    Winslow, E.H.2    Tyler, D.O.3    White, K.M.4
  • 12
    • 0023747264 scopus 로고
    • Airway pressures during closed system suctioning
    • Taggart JA, Sheahan JS. Airway pressures during closed system suctioning. Heart Lung 1988;17:536-42.
    • (1988) Heart Lung , vol.17 , pp. 536-542
    • Taggart, J.A.1    Sheahan, J.S.2
  • 13
    • 1642319521 scopus 로고    scopus 로고
    • Complications of endotracheal suctioning (ES) during mechanical ventilation: Incidence and risk factors
    • Maggiore S, Pigeot J, Lellouche F, Deye N, Taillé S, Blasi F et al. Complications of endotracheal suctioning (ES) during mechanical ventilation: incidence and risk factors. Intensive Care Med 2001;27(Suppl 2):S246.
    • (2001) Intensive Care Med , vol.27 , Issue.SUPPL. 2
    • Maggiore, S.1    Pigeot, J.2    Lellouche, F.3    Deye, N.4    Taillé, S.5    Blasi, F.6
  • 14
    • 0026375220 scopus 로고
    • Constant-flow insufflation prevents arterial oxygen desaturation during endotracheal suctioning
    • Brochard L, Mion G, Isabey D, Bertrand C, Messadi AA, Mancebo J et al. Constant-flow insufflation prevents arterial oxygen desaturation during endotracheal suctioning. Am Rev Respir Dis 1991;144:395-400.
    • (1991) Am Rev Respir Dis , vol.144 , pp. 395-400
    • Brochard, L.1    Mion, G.2    Isabey, D.3    Bertrand, C.4    Messadi, A.A.5    Mancebo, J.6
  • 15
    • 0035044375 scopus 로고    scopus 로고
    • Closed system endotracheal suctioning maintains lung volume during volume-controlled mechanical ventilation
    • Cereda M, Villa F, Colombo E, Greco G, Nacoti M, Pesenti A. Closed system endotracheal suctioning maintains lung volume during volume-controlled mechanical ventilation. Intensive Care Med 2001;27:648-54.
    • (2001) Intensive Care Med , vol.27 , pp. 648-654
    • Cereda, M.1    Villa, F.2    Colombo, E.3    Greco, G.4    Nacoti, M.5    Pesenti, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.