메뉴 건너뛰기




Volumn 60, Issue 5, 2002, Pages 631-634

The application of ultrasonic attenuation measurements to estimate corrosion in pipeline at support structures

Author keywords

Decibel decay rate; Pipe corrosion at support; Taguchi method; Ultrasonic attenuation; Wall loss ratio

Indexed keywords

ATTENUATION; CALCULATIONS; CORROSION; COST EFFECTIVENESS; FAILURE ANALYSIS; PETROLEUM INDUSTRY; PIPELINES;

EID: 0036565369     PISSN: 00255327     EISSN: None     Source Type: Trade Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (17)
  • 4
  • 12
    • 0032632652 scopus 로고    scopus 로고
    • Guided waves by axisymmetric and non-axisymmetric surface loading on hollow cylinders
    • (1999) Ultrasonics , vol.37 , pp. 355-363
    • Shin, H.J.1    Rose, J.L.2
  • 14
    • 0005928750 scopus 로고    scopus 로고
    • A non-destructive screening technique for the detection of metal loss in pipeline and process pipe work
    • TeleTest Technology of Plant Integrity, Ltd.; June
    • (2000)
  • 16
    • 25544475687 scopus 로고    scopus 로고
    • The development of inspection technique for corrosion under support of petroleum pipeline
    • Division of Occupational Safety and Health, Council of Labor Affairs, Executive Yuan, Taiwan
    • (1999)
    • Wu, Y.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.