메뉴 건너뛰기




Volumn 35, Issue 4, 2002, Pages 679-685

Potential impact of therapeutic warfarin treatment on type II endoleaks and sac shrinkage rates on midterm follow-up examination

Author keywords

[No Author keywords available]

Indexed keywords

WARFARIN; ANTICOAGULANT AGENT;

EID: 0036548045     PISSN: 07415214     EISSN: None     Source Type: Journal    
DOI: 10.1067/mva.2002.121570     Document Type: Article
Times cited : (52)

References (16)
  • 1
    • 0032061766 scopus 로고    scopus 로고
    • Type 1 and type 2 endoleaks: A more useful classification for reporting results of endoluminal AAA repair
    • letter to the editor
    • White GH, May J, Waugh R, Yu W. Type 1 and type 2 endoleaks: a more useful classification for reporting results of endoluminal AAA repair [letter to the editor]. J Endovasc Surg 1998;5:189-93.
    • (1998) J Endovasc Surg , vol.5 , pp. 189-193
    • White, G.H.1    May, J.2    Waugh, R.3    Yu, W.4
  • 2
    • 0034015912 scopus 로고    scopus 로고
    • Diagnosis and treatment of inferior mesenteric arterial endoleaks after endovascular repair of abdominal aortic aneurysms
    • Baum RA, Carpenter JP, Tuite CM, Velazquez OC, Soulen MC, Barker CF, et al. Diagnosis and treatment of inferior mesenteric arterial endoleaks after endovascular repair of abdominal aortic aneurysms. Radiology 2000;215:409-13.
    • (2000) Radiology , vol.215 , pp. 409-413
    • Baum, R.A.1    Carpenter, J.P.2    Tuite, C.M.3    Velazquez, O.C.4    Soulen, M.C.5    Barker, C.F.6
  • 3
    • 0035117759 scopus 로고    scopus 로고
    • The Ancure endografting system: Anupdate
    • Makaroun MS. The Ancure endografting system: anupdate. J Vasc Surg 2001;33:S129-34.
    • (2001) J Vasc Surg , vol.33
    • Makaroun, M.S.1
  • 5
    • 0033782708 scopus 로고    scopus 로고
    • Relationship between preoperative patency of the inferior mesenteric artery and subsequent occurrence of type II endoleaks in patients undergoing endovascular repair of AAA
    • Velazquez OC, Baum RA, Carpenter JP, Golden MA, Cohn M, Pyeron A, et al. Relationship between preoperative patency of the inferior mesenteric artery and subsequent occurrence of type II endoleaks in patients undergoing endovascular repair of AAA. J Vasc Surg 2000;32:777-88.
    • (2000) J Vasc Surg , vol.32 , pp. 777-788
    • Velazquez, O.C.1    Baum, R.A.2    Carpenter, J.P.3    Golden, M.A.4    Cohn, M.5    Pyeron, A.6
  • 6
    • 0031820342 scopus 로고    scopus 로고
    • Rupture of abdominal aortic aneurysm previously treated by endovascular stentgraft
    • Torsello GB, Klenk E, Kasprzak B, Umscheid T. Rupture of abdominal aortic aneurysm previously treated by endovascular stentgraft. J Vasc Surg 1998;28:184-7.
    • (1998) J Vasc Surg , vol.28 , pp. 184-187
    • Torsello, G.B.1    Klenk, E.2    Kasprzak, B.3    Umscheid, T.4
  • 9
    • 0032801835 scopus 로고    scopus 로고
    • The incidence, natural history, and outcome of secondary intervention for persistent collateral flow in the excluded abdominal aortic aneurysm
    • Darling RC III, Ozsvath K, Chang BB, Kreienberg PB, Paty PS, Lloyd WE, et al. The incidence, natural history, and outcome of secondary intervention for persistent collateral flow in the excluded abdominal aortic aneurysm. J Vasc Surg 1999;30:968-76.
    • (1999) J Vasc Surg , vol.30 , pp. 968-976
    • Darling III, R.C.1    Ozsvath, K.2    Chang, B.B.3    Kreienberg, P.B.4    Paty, P.S.5    Lloyd, W.E.6
  • 11
    • 0031849583 scopus 로고    scopus 로고
    • Endoleakage after stent graft treatment of abdominal aneurysm: Implications on pressure and imaging-an in vitro study
    • Schurink GW, Aarts NJ, Wilde J, van Baalen JM, Chuter TA, Schultze Kool LJ, et al. Endoleakage after stent graft treatment of abdominal aneurysm: implications on pressure and imaging-an in vitro study. J Vasc Surg 1998;28:234-41.
    • (1998) J Vasc Surg , vol.28 , pp. 234-241
    • Schurink, G.W.1    Aarts, N.J.2    Wilde, J.3    Van Baalen, J.M.4    Chuter, T.A.5    Schultze Kool, L.J.6
  • 12
    • 0034235576 scopus 로고    scopus 로고
    • Rate of change in abdominal aortic aneurysm diameter after endovascular repair
    • Wolf YG, Hill BB, Rubin GD, Fogarty TJ, Zarins CK. Rate of change in abdominal aortic aneurysm diameter after endovascular repair. J Vasc Surg 2000;32:108-15.
    • (2000) J Vasc Surg , vol.32 , pp. 108-115
    • Wolf, Y.G.1    Hill, B.B.2    Rubin, G.D.3    Fogarty, T.J.4    Zarins, C.K.5
  • 13
    • 0034235048 scopus 로고    scopus 로고
    • Endoleak as a predictor of outcome after endovascular aneurysm repair: AneuRx multicenter clinical trial
    • Zarins CK, White RA, Hodgson KJ, Schwarten D, Fogarty TJ. Endoleak as a predictor of outcome after endovascular aneurysm repair: AneuRx multicenter clinical trial. J Vasc Surg 2000;32:90-107.
    • (2000) J Vasc Surg , vol.32 , pp. 90-107
    • Zarins, C.K.1    White, R.A.2    Hodgson, K.J.3    Schwarten, D.4    Fogarty, T.J.5
  • 14
    • 0033867552 scopus 로고    scopus 로고
    • Aortic aneurysm size and graft behavior after endovascular stent grafting: Clinical experiences and observations over 3 years
    • Schunn CD, Krauss M, Heilberger P, Ritter W, Raithel D. Aortic aneurysm size and graft behavior after endovascular stent grafting: clinical experiences and observations over 3 years. J Endovasc Ther 2000;7:167-76.
    • (2000) J Endovasc Ther , vol.7 , pp. 167-176
    • Schunn, C.D.1    Krauss, M.2    Heilberger, P.3    Ritter, W.4    Raithel, D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.