메뉴 건너뛰기




Volumn 28, Issue 2, 2002, Pages 88-93

Visual performance of a multi-zone bifocal and a progressive multifocal contact lens

Author keywords

High contrast; High luminance; Low contrast; Low luminance; Multi zone bifocal contact lens; Multifocal contact lens; Presbyopia contact lens; Visual acuity

Indexed keywords

ARTICLE; CONTACT LENS; PRESBYOPIA; VISION; VISUAL ACUITY; ADULT; AGED; BINOCULAR VISION; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CROSSOVER PROCEDURE; DOUBLE BLIND PROCEDURE; EQUIPMENT DESIGN; HUMAN; ILLUMINATION; MIDDLE AGED; PATHOPHYSIOLOGY; RANDOMIZED CONTROLLED TRIAL;

EID: 0036527576     PISSN: 07338902     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (34)

References (21)
  • 1
    • 0001940066 scopus 로고    scopus 로고
    • The contact lens spectrum millennium report
    • Barr JT. The Contact Lens Spectrum Millennium Report. CL Spectrum 2000;14(1):24-30.
    • (2000) CL Spectrum , vol.14 , Issue.1 , pp. 24-30
    • Barr, J.T.1
  • 2
    • 0008052622 scopus 로고    scopus 로고
    • Trends in UK contact lens prescribing 2000
    • Morgan P, Efron N. Trends in UK contact lens prescribing 2000. Optician 2000;5749(219)2-23.
    • (2000) Optician , vol.5749 , Issue.219 , pp. 2-23
    • Morgan, P.1    Efron, N.2
  • 3
    • 27844478868 scopus 로고    scopus 로고
    • Contact Lenses 2000
    • Barr JT. Contact Lenses 2000. CL Spectrum 2001;16(1):23-29.
    • (2001) CL Spectrum , vol.16 , Issue.1 , pp. 23-29
    • Barr, J.T.1
  • 4
    • 38249021172 scopus 로고
    • Theoretical and practical factors influencing the optical performance of contact lenses for the presbyope
    • Charman WN, Saunders B. Theoretical and practical factors influencing the optical performance of contact lenses for the presbyope. J Brit Contact Lens Assoc 1990;13(1):67-75.
    • (1990) J Brit Contact Lens Assoc , vol.13 , Issue.1 , pp. 67-75
    • Charman, W.N.1    Saunders, B.2
  • 5
    • 0010777281 scopus 로고
    • Retinal images with centered, aspheric varifocal contact lenses
    • Charman WN, Walsh G. Retinal images with centered, aspheric varifocal contact lenses. ICLC 1988;15(3):87-93.
    • (1988) ICLC , vol.15 , Issue.3 , pp. 87-93
    • Charman, W.N.1    Walsh, G.2
  • 6
    • 0023947087 scopus 로고
    • Pupil dependency of bifocal contact lenses
    • Borish IM. Pupil dependency of bifocal contact lenses. Am J Physiol Opt 1988;65(5):417-423.
    • (1988) Am J Physiol Opt , vol.65 , Issue.5 , pp. 417-423
    • Borish, I.M.1
  • 7
    • 0025102329 scopus 로고
    • Simultaneous vision bifocal contact lenses: A comparative assessment of the in vitro optical performance
    • Young G, Grey CP, Papas EB. Simultaneous vision bifocal contact lenses: a comparative assessment of the in vitro optical performance. Optom Vis Sci 1990;67(5):339-345.
    • (1990) Optom Vis Sci , vol.67 , Issue.5 , pp. 339-345
    • Young, G.1    Grey, C.P.2    Papas, E.B.3
  • 8
    • 0000717458 scopus 로고
    • Quality of vision with hydrogel simultaneous vision bifocal contact lenses
    • McGill E, Ames K, Erickson P, Robboy M. Quality of vision with hydrogel simultaneous vision bifocal contact lenses. ICLC 1987;14(12)476-482.
    • (1987) ICLC , vol.14 , Issue.12 , pp. 476-482
    • McGill, E.1    Ames, K.2    Erickson, P.3    Robboy, M.4
  • 9
    • 0027273259 scopus 로고
    • Subjective and objective assessment of soft bifocal contact lens performance
    • Bullimore MA, Jacobs RJ. Subjective and objective assessment of soft bifocal contact lens performance. Optom Vis Sci 1993;70(6):469-475.
    • (1993) Optom Vis Sci , vol.70 , Issue.6 , pp. 469-475
    • Bullimore, M.A.1    Jacobs, R.J.2
  • 10
    • 0022356924 scopus 로고
    • Performance characteristics of a hydrophilic concentric bifocal contact lens
    • Erickson P, Robboy M. Performance characteristics of a hydrophilic concentric bifocal contact lens. Am J Optom Physiol Opt 1985;62(10):702-708.
    • (1985) Am J Optom Physiol Opt , vol.62 , Issue.10 , pp. 702-708
    • Erickson, P.1    Robboy, M.2
  • 12
    • 0033281914 scopus 로고    scopus 로고
    • Evaluation of two new soft contact lenses for correction of presbyopia
    • Fisher K, Bauman E, Schwallie J. Evaluation of two new soft contact lenses for correction of presbyopia. ICLC 1999;26:92-101.
    • (1999) ICLC , vol.26 , pp. 92-101
    • Fisher, K.1    Bauman, E.2    Schwallie, J.3
  • 13
    • 0003255160 scopus 로고    scopus 로고
    • A new 'pupil-intelligent' design for presbyopic correction
    • Meyler J, Veys J. A new 'pupil-intelligent' design for presbyopic correction. Optician 1999;217(5687):18-23.
    • (1999) Optician , vol.217 , Issue.5687 , pp. 18-23
    • Meyler, J.1    Veys, J.2
  • 14
    • 18744370930 scopus 로고
    • Precision of LogMAR visual acuity measurement
    • Costes Y, Guillon M, Guillon JP. Precision of LogMAR visual acuity measurement. Optom Vis Sci 1994;71(12S):58.
    • (1994) Optom Vis Sci , vol.71 , Issue.12 S , pp. 58
    • Costes, Y.1    Guillon, M.2    Guillon, J.P.3
  • 15
    • 0017052413 scopus 로고
    • New design principles for visual acuity letter charts
    • Bailey IL, Lovie JE. New design principles for visual acuity letter charts. Am J Physiol Opt 1976;53:740.
    • (1976) Am J Physiol Opt , vol.53 , pp. 740
    • Bailey, I.L.1    Lovie, J.E.2
  • 17
    • 0025869727 scopus 로고
    • Soft contact lens visual performance: A multicenter study
    • Guillon M, Schock SE. Soft contact lens visual performance: a multicenter study. Optom Vis Sci 1991;68(2):96-103.
    • (1991) Optom Vis Sci , vol.68 , Issue.2 , pp. 96-103
    • Guillon, M.1    Schock, S.E.2
  • 18
    • 38249004267 scopus 로고
    • Visual performance stability of disposable contact lenses
    • Guillon M, Guillon J-P, Shah D. Visual performance stability of disposable contact lenses. ICLC 1993;20:7-16.
    • (1993) ICLC , vol.20 , pp. 7-16
    • Guillon, M.1    Guillon, J.-P.2    Shah, D.3
  • 19
    • 0006820929 scopus 로고
    • Critical assessment of visual performance in contact lens practice
    • Guillon M, Sayer G. Critical assessment of visual performance in contact lens practice. Contax 1988;May:8-13.
    • (1988) Contax , vol.MAY , pp. 8-13
    • Guillon, M.1    Sayer, G.2
  • 20
    • 0025683421 scopus 로고
    • A standard practice for roadway lighting based on driver performance
    • Janoff MS. A standard practice for roadway lighting based on driver performance. J Illum Eng Soc 1990;19:47-51.
    • (1990) J Illum Eng Soc , vol.19 , pp. 47-51
    • Janoff, M.S.1
  • 21
    • 0008538139 scopus 로고    scopus 로고
    • Fitting a soft disposable bifocal lens
    • Lloyd M. Fitting a soft disposable bifocal lens. Optician 1999;217(5691):18-22.
    • (1999) Optician , vol.217 , Issue.5691 , pp. 18-22
    • Lloyd, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.