메뉴 건너뛰기




Volumn 9, Issue 2, 2002, Pages 197-205

Removal of liver activity contamination in teboroxime dynamic cardiac SPECT imaging with the use of factor analysis

Author keywords

Dynamic single photon emission computed tomography; Least squares factor analysis of dynamic structures; Liver activity; Teboroxime

Indexed keywords

TEBOROXIME TC 99M;

EID: 0036520855     PISSN: 10713581     EISSN: None     Source Type: Journal    
DOI: 10.1067/mnc.2002.120362     Document Type: Article
Times cited : (14)

References (21)
  • 2
    • 0025129197 scopus 로고
    • Comparative myocardial extraction of two technetium-labeled BATO derivatives (SQ30217, SQ32014) and thallium
    • Leppo JA, Meerdink DJ. Comparative myocardial extraction of two technetium-labeled BATO derivatives (SQ30217, SQ32014) and thallium. J Nucl Med 1990;31:67-74.
    • (1990) J. Nucl. Med , vol.31 , pp. 67-74
    • Leppo, J.A.1    Meerdink, D.J.2
  • 3
    • 0026040861 scopus 로고
    • A review of cardiac imaging with sestamibi and teboroxime
    • Leppo JA, DePuey EG, Johnson LL. A review of cardiac imaging with sestamibi and teboroxime. J Nucl Med 1991;32: 2012-21.
    • (1991) J. Nucl. Med , vol.32 , pp. 2012-2021
    • Leppo, J.A.1    DePuey, E.G.2    Johnson, L.L.3
  • 4
    • 0028264788 scopus 로고
    • Kinetic modeling of teboroxime using dynamic SPECT imaging of a canine model
    • Smith AM, Gullberg GT, Christian PE, Datz FL. Kinetic modeling of teboroxime using dynamic SPECT imaging of a canine model. J Nucl Med 1994;35:484-95.
    • (1994) J. Nucl. Med , vol.35 , pp. 484-495
    • Smith, A.M.1    Gullberg, G.T.2    Christian, P.E.3    Datz, F.L.4
  • 5
    • 0028093280 scopus 로고
    • Compartmental analysis of technetium-99m-teboroxime kinetics employing fast dynamic SPECT at rest and stress
    • Chiao P-C, Ficaro EP, Dayanikli F, Rogers WL, Schwaiger M. Compartmental analysis of technetium-99m-teboroxime kinetics employing fast dynamic SPECT at rest and stress. J Nucl Med 1994;35:1256-73.
    • (1994) J. Nucl. Med , vol.35 , pp. 1256-1273
    • Chiao, P.-C.1    Ficaro, E.P.2    Dayanikli, F.3    Rogers, W.L.4    Schwaiger, M.5
  • 6
    • 0029995088 scopus 로고    scopus 로고
    • Experimental verification of technetium 99m-labeled teboroxime kinetic parameters in the myocardium with dynamic single-photon emission computed tomography: Reproducibility, correlation to flow, and susceptibility to extravascular contamination
    • Smith AM, Gullberg GT, Christian PE. Experimental verification of technetium 99m-labeled teboroxime kinetic parameters in the myocardium with dynamic single-photon emission computed tomography: reproducibility, correlation to flow, and susceptibility to extravascular contamination. J Nucl Cardiol 1996;3:130-42.
    • (1996) J. Nucl. Cardiol , vol.3 , pp. 130-142
    • Smith, A.M.1    Gullberg, G.T.2    Christian, P.E.3
  • 8
    • 0025740824 scopus 로고
    • Technetium-99m teboroxime scintigraphy. Clinical experience in patients referred for myocardial perfusion evaluation
    • Bontemps L, Geronicola-Trapali X, Sayegh Y, Delmas O, Itti R, Andre X. Technetium-99m teboroxime scintigraphy. Clinical experience in patients referred for myocardial perfusion evaluation. Eur J Nucl Med 1991;18:732-39.
    • (1991) Eur. J. Nucl. Med , vol.18 , pp. 732-739
    • Bontemps, L.1    Geronicola-Trapali, X.2    Sayegh, Y.3    Delmas, O.4    Itti, R.5    Andre, X.6
  • 9
    • 0027291647 scopus 로고
    • Rapid back to back adenosine stress/rest technetium-99m teboroxime myocardial perfusion SPECT using a triple-detector camera
    • Chua T, Kiat H, Germano G, Takemoto K, Fernandez G, Baisio Y, et al. Rapid back to back adenosine stress/rest technetium-99m teboroxime myocardial perfusion SPECT using a triple-detector camera. J Nucl Med 1993;34:1485-93.
    • (1993) J. Nucl. Med , vol.34 , pp. 1485-1493
    • Chua, T.1    Kiat, H.2    Germano, G.3    Takemoto, K.4    Fernandez, G.5    Baisio, Y.6
  • 11
    • 0027234406 scopus 로고
    • A statistical model for the determination of an optimal metric in factor analysis of medical sequences (FAMIS)
    • Benali H, Buvat I, Frouin F, Bazin JP, Di Paola R. A statistical model for the determination of an optimal metric in factor analysis of medical sequences (FAMIS). Phys Med Biol 1993; 38:1065-82.
    • (1993) Phys. Med. Biol , vol.38 , pp. 1065-1082
    • Benali, H.1    Buvat, I.2    Frouin, F.3    Bazin, J.P.4    Di Paola, R.5
  • 12
    • 0033804685 scopus 로고    scopus 로고
    • Factor analysis with a priori knowledge-application in dynamic cardiac SPECT
    • Sitek A, Di Bella EVR, Gullberg GT. Factor analysis with a priori knowledge-application in dynamic cardiac SPECT. Phys Med Biol 2000;45:2619-38.
    • (2000) Phys. Med. Biol , vol.45 , pp. 2619-2638
    • Sitek, A.1    Di Bella, E.V.R.2    Gullberg, G.T.3
  • 13
    • 0034593783 scopus 로고    scopus 로고
    • Correction for ambiguous solutions in factor analysis using a penalized least squares objective
    • 2000 IEEE Nuclear Science Symposium and Medical Imaging Conference Record. Lyon, France: October 15-20
    • Sitek A, Gullberg GT, Huesman RH. Correction for ambiguous solutions in factor analysis using a penalized least squares objective. In: 2000 IEEE Nuclear Science Symposium and Medical Imaging Conference Record. Lyon, France: October 15-20, 2000. p. 2292-6.
    • (2000) , pp. 2292-2296
    • Sitek, A.1    Gullberg, G.T.2    Huesman, R.H.3
  • 15
    • 0034529901 scopus 로고    scopus 로고
    • Performance of the dynamic single photon emission computed tomography (dSPECT) method for decreasing or increasing activity changes
    • Celler A, Farncombe T, Bever JM, Noll D, Maeght J, Harrop R, et al. Performance of the dynamic single photon emission computed tomography (dSPECT) method for decreasing or increasing activity changes. Phys Med Biol 2000;45:3525-43.
    • (2000) Phys. Med. Biol , vol.45 , pp. 3525-3543
    • Celler, A.1    Farncombe, T.2    Bever, J.M.3    Noll, D.4    Maeght, J.5    Harrop, R.6
  • 16
    • 84947419641 scopus 로고    scopus 로고
    • Reconstruction from slow rotation dynamic SPECT using a factor model
    • Kuba A, Samal M, Todd-Pokropek A, eds. Lecture notes in computer science 1613. Information processing in medical imaging. proceedings of the 16th international conference. Springer: Berlin
    • Sitek A, Di Bella EVR, Gullberg GT. Reconstruction from slow rotation dynamic SPECT using a factor model. In: Kuba A, Samal M, Todd-Pokropek A, eds. Lecture notes in computer science 1613. Information processing in medical imaging. proceedings of the 16th international conference. Springer: Berlin, 1999. p. 436-41.
    • (1999) , pp. 436-441
    • Sitek, A.1    Di Bella, E.V.R.2    Gullberg, G.T.3
  • 17
    • 0035212751 scopus 로고    scopus 로고
    • Reconstruction of dynamic renal tomographic data acquired by slow rotation
    • Sitek A, Gullberg GT, Di Bella EVR, Celler A. Reconstruction of dynamic renal tomographic data acquired by slow rotation. J Nucl Med 2001;42:1704-12.
    • (2001) J. Nucl. Med , vol.42 , pp. 1704-1712
    • Sitek, A.1    Gullberg, G.T.2    Di Bella, E.V.R.3    Celler, A.4
  • 18
    • 0036489379 scopus 로고    scopus 로고
    • Correction for ambiguous solutions in factor analysis using a penalized least squares objective
    • (In press.)
    • Sitek A, Gullberg GT, Huesman RH. Correction for ambiguous solutions in factor analysis using a penalized least squares objective. IEEE Trans Med Imaging 2002. (In press.)
    • (2002) IEEE Trans. Med. Imaging
    • Sitek, A.1    Gullberg, G.T.2    Huesman, R.H.3
  • 19
    • 0027842861 scopus 로고
    • Evaluation of cardiac cone-beam SPECT using observer performance experiments and ROC analysis
    • (In press)
    • Tsui BMW, Terry JA, Gullberg GT. Evaluation of cardiac cone-beam SPECT using observer performance experiments and ROC analysis (In press). Invest Radiol 1993;28:1101-28.
    • (1993) Invest. Radiol , vol.28 , pp. 1101-1128
    • Tsui, B.M.W.1    Terry, J.A.2    Gullberg, G.T.3
  • 20
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • (In press)
    • Shepp LA, Vardi Y. Maximum likelihood reconstruction for emission tomography (In press). IEEE Trans Med Imaging 1982;1: 113-22.
    • (1982) IEEE Trans. Med. Imaging , vol.1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 21
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • (In press)
    • Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data (In press). IEEE Trans Med Imaging 1994;13:601-9.
    • (1994) IEEE Trans. Med. Imaging , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.