메뉴 건너뛰기




Volumn 42, Issue 3, 2002, Pages 375-379

Response to vWF-coated beads and soluble p-selectin to characterize apheresis platelets: A comparison of three cell separators

Author keywords

[No Author keywords available]

Indexed keywords

MICROSPHERE; PADGEM PROTEIN; VON WILLEBRAND FACTOR;

EID: 0036516518     PISSN: 00411132     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1537-2995.2002.00041.x     Document Type: Article
Times cited : (5)

References (20)
  • 1
    • 0026539488 scopus 로고
    • Effects of prestorage white cell‐reduction of apheresis platelets on platelet glycoprotein Ib and von Willebrand factor.
    • 1 Garcia GI, Fitzpatrick JE, Hoernig LA, et al. Effects of prestorage white cell‐reduction of apheresis platelets on platelet glycoprotein Ib and von Willebrand factor. Transfusion 1992 ; 32: 148 ‐ 51.
    • (1992) Transfusion , vol.32 , pp. 148-51
    • Garcia, GI1    Fitzpatrick, JE2    Hoernig, LA3
  • 2
    • 0027370973 scopus 로고
    • Effect of prestorage leukocyte reduction on proteins of platelets obtained by apheresis.
    • 2 Sarraj‐Reguieg A, Tissot JD, Hochstrasser DF, et al. Effect of prestorage leukocyte reduction on proteins of platelets obtained by apheresis. Vox Sang 1993 ; 65: 279 ‐ 85.
    • (1993) Vox Sang , vol.65 , pp. 279-85
    • Sarraj‐Reguieg, A1    Tissot, JD2    Hochstrasser, DF3
  • 3
    • 0027204762 scopus 로고
    • Storage of single‐donor platelet concentrates: metabolic and functional changes.
    • 3 Bock M, Glaser A, Pfosser A, et al. Storage of single‐donor platelet concentrates: metabolic and functional changes. Transfusion 1993 ; 33: 311 ‐ 5.
    • (1993) Transfusion , vol.33 , pp. 311-5
    • Bock, M1    Glaser, A2    Pfosser, A3
  • 4
    • 0032446831 scopus 로고    scopus 로고
    • A method for the quantitative assessment of platelet‐induced clot retraction and clot strength in fresh and stored platelets.
    • 4 Reid TJ, Snider R, Hartman K, et al. A method for the quantitative assessment of platelet‐induced clot retraction and clot strength in fresh and stored platelets. Vox Sang 1998 ; 75: 270 ‐ 7.
    • (1998) Vox Sang , vol.75 , pp. 270-7
    • Reid, TJ1    Snider, R2    Hartman, K3
  • 5
    • 0035103078 scopus 로고    scopus 로고
    • Effect of gamma radiation on the in vitro aggregability of WBC‐reduced apheresis platelets.
    • 5 Zimmermann R, Schmidt S, Zingsem J, et al. Effect of gamma radiation on the in vitro aggregability of WBC‐reduced apheresis platelets. Transfusion 2001 ; 41: 236 ‐ 42.
    • (2001) Transfusion , vol.41 , pp. 236-42
    • Zimmermann, R1    Schmidt, S2    Zingsem, J3
  • 6
    • 0030473089 scopus 로고    scopus 로고
    • Detection of platelet adhesion/aggregation to immobilized ligands on microbeads by an aggregometer.
    • 6 Minamoto Y, Hato T, Nakatani S, Fujita S. Detection of platelet adhesion/aggregation to immobilized ligands on microbeads by an aggregometer. Thromb Haemost 1996 ; 76: 1072 ‐ 9.
    • (1996) Thromb Haemost , vol.76 , pp. 1072-9
    • Minamoto, Y1    Hato, T2    Nakatani, S3    Fujita, S4
  • 7
    • 0030923355 scopus 로고    scopus 로고
    • Platelet activation by a novel solid‐phase agonist: effects of VWF immobilized on polystrene beads.
    • 7 Stewart MW, Etches WS, Boshkov LK, et al. Platelet activation by a novel solid‐phase agonist: effects of VWF immobilized on polystrene beads. Br J Haematol 1997 ; 97: 321 ‐ 9.
    • (1997) Br J Haematol , vol.97 , pp. 321-9
    • Stewart, MW1    Etches, WS2    Boshkov, LK3
  • 8
    • 0025724038 scopus 로고
    • Von Willebrand factor binding to platelet GpIb initiates signals for platelet activation.
    • 8 Kroll MH, Harris TS, Moake JL, et al. Von Willebrand factor binding to platelet GpIb initiates signals for platelet activation. J Clin Invest 1991 ; 88: 1568 ‐ 73.
    • (1991) J Clin Invest , vol.88 , pp. 1568-73
    • Kroll, MH1    Harris, TS2    Moake, JL3
  • 9
    • 0034283493 scopus 로고    scopus 로고
    • Inhibitory activity of aspirin on von Willebrand factor‐induced platelet aggregation.
    • 9 Homoncik M, Jilma B, Eichelberger B, Panzer S. Inhibitory activity of aspirin on von Willebrand factor‐induced platelet aggregation. Thromb Res 2000 ; 99: 461 ‐ 6.
    • (2000) Thromb Res , vol.99 , pp. 461-6
    • Homoncik, M1    Jilma, B2    Eichelberger, B3    Panzer, S4
  • 10
    • 0030470608 scopus 로고    scopus 로고
    • Soluble P‐selectin as parameter for platelet activation during storage.
    • 10 Kostelijk EH, Fijnheer R, Nieuwenhuis HK, et al. Soluble P‐selectin as parameter for platelet activation during storage. Thromb Haemost 1996 ; 76: 1086 ‐ 9.
    • (1996) Thromb Haemost , vol.76 , pp. 1086-9
    • Kostelijk, EH1    Fijnheer, R2    Nieuwenhuis, HK3
  • 11
    • 0031936856 scopus 로고    scopus 로고
    • Differential induction of P‐selectin expression on platelets by two cell separators during plateletpheresis and effect of gender on the release of soluble P‐selectin.
    • 11 Stohlawetz P, Hergovich N, Stiegler G, et al. Differential induction of P‐selectin expression on platelets by two cell separators during plateletpheresis and effect of gender on the release of soluble P‐selectin. Transfusion 1998 ; 38: 24 ‐ 30.
    • (1998) Transfusion , vol.38 , pp. 24-30
    • Stohlawetz, P1    Hergovich, N2    Stiegler, G3
  • 12
    • 0033051307 scopus 로고    scopus 로고
    • Is soluble P‐selectin determination a more reliable marker of in vivo platelet activation than CD62P flow cytometric analysis.
    • 12 Ferroni P, Pulcinelli FM, Lenti L, Gazzaniga PP. Is soluble P‐selectin determination a more reliable marker of in vivo platelet activation than CD62P flow cytometric analysis. Thromb Haemost 1999 ; 81: 472 ‐ 3.
    • (1999) Thromb Haemost , vol.81 , pp. 472-3
    • Ferroni, P1    Pulcinelli, FM2    Lenti, L3    Gazzaniga, PP4
  • 13
    • 0032776112 scopus 로고    scopus 로고
    • Platelet surface p‐selectin, platelet‐granulocyte heterotypic aggregates, and plasma‐soluble p‐selectin during plateletpheresis.
    • 13 Barnard MR, MacGregor H, Mercier R, et al. Platelet surface p‐selectin, platelet‐granulocyte heterotypic aggregates, and plasma‐soluble p‐selectin during plateletpheresis. Transfusion 1999 ; 39: 735 ‐ 41.
    • (1999) Transfusion , vol.39 , pp. 735-41
    • Barnard, MR1    MacGregor, H2    Mercier, R3
  • 14
    • 85120588532 scopus 로고    scopus 로고
    • 14 Guide to the preparation, use, and quality control of blood components, 7th ed. Strasbourg: Council of Europe Publishing; 2001.
  • 15
    • 0031014767 scopus 로고    scopus 로고
    • The expression of p‐selectin during, collection, processing, and storage of platelet concentrates: relationship to loss of in vivo viability.
    • 15 Holme S, Sweeney JD, Sawyer S, Elfath MD. The expression of p‐selectin during, collection, processing, and storage of platelet concentrates: relationship to loss of in vivo viability. Transfusion 1997 ; 37: 12 ‐ 7.
    • (1997) Transfusion , vol.37 , pp. 12-7
    • Holme, S1    Sweeney, JD2    Sawyer, S3    Elfath, MD4
  • 16
    • 0033970369 scopus 로고    scopus 로고
    • Apheresis‐induced platelet activation: comparison of three types of cell separators.
    • 16 Hagberg IA, Akkok CA, Lyberg T, Kjeldsen‐Kragh J. Apheresis‐induced platelet activation: comparison of three types of cell separators. Transfusion 2000 ; 40: 182 ‐ 92.
    • (2000) Transfusion , vol.40 , pp. 182-92
    • Hagberg, IA1    Akkok, CA2    Lyberg, T3    Kjeldsen‐Kragh, J4
  • 17
    • 0027402598 scopus 로고
    • Activation in stored platelet concentrates: correlation between membrane expression of P‐selectin, glycoprotein IIb/IIIa and β‐thromboglobulin release.
    • 17 Rinder HM, Synder EL, Bonan JI, et al. Activation in stored platelet concentrates: correlation between membrane expression of P‐selectin, glycoprotein IIb/IIIa and β‐thromboglobulin release. Transfusion 1993 ; 33: 25 ‐ 9 ; erratum in Transfusion 1993;33:275.
    • (1993) Transfusion , vol.33 , pp. 25-9
    • Rinder, HM1    Synder, EL2    Bonan, JI3
  • 18
    • 0029973981 scopus 로고    scopus 로고
    • In vivo tracking of platelets: circulating degranulated platelets rapidly lose surface p‐selectin but continue to circulate and function.
    • 18 Michelson AD, Barnard MR, Hechtmann HB, et al. In vivo tracking of platelets: circulating degranulated platelets rapidly lose surface p‐selectin but continue to circulate and function. Proc Natl Acad Sci U S A 1996 ; 93: 11877 ‐ 82.
    • (1996) Proc Natl Acad Sci U S A , vol.93 , pp. 11877-82
    • Michelson, AD1    Barnard, MR2    Hechtmann, HB3
  • 19
    • 0032400835 scopus 로고    scopus 로고
    • P‐selectin and platelet clearance.
    • 19 Berger G, Hartwell DW, Wagner DD. P‐selectin and platelet clearance. Blood 1998 ; 92: 4446 ‐ 52.
    • (1998) Blood , vol.92 , pp. 4446-52
    • Berger, G1    Hartwell, DW2    Wagner, DD3
  • 20
    • 0032926801 scopus 로고    scopus 로고
    • Effects of nitric oxide on platelet activation during plateletpheresis and in vivo tracking of biotinylated platelets in humans.
    • 20 Stohlawetz P, Horvath M, Pernerstorfer T, et al. Effects of nitric oxide on platelet activation during plateletpheresis and in vivo tracking of biotinylated platelets in humans. Transfusion 1999 ; 39: 506 ‐ 14.
    • (1999) Transfusion , vol.39 , pp. 506-14
    • Stohlawetz, P1    Horvath, M2    Pernerstorfer, T3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.