메뉴 건너뛰기




Volumn 32, Issue 3, 2002, Pages 379-385

Defect dynamics of cement mortar under repeated loading, studied by electrical resistivity measurement

Author keywords

Electrical Properties; Microcracking; Microstructure; Mortar; Strain effect

Indexed keywords

CRYSTAL DEFECTS; ELECTRIC CONDUCTIVITY; MICROCRACKING; MICROSTRUCTURE; MORTAR; SILICA;

EID: 0036499350     PISSN: 00088846     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0008-8846(01)00686-X     Document Type: Article
Times cited : (11)

References (36)
  • 1
    • 0035477344 scopus 로고    scopus 로고
    • Defect dynamics of cement paste under repeated compression, studied by electrical resistivity measurement
    • (2001) Cem. Concr. Res. , vol.31 , Issue.10 , pp. 1515-1518
    • Wen, S.1    Chung, D.D.L.2
  • 16
    • 0033352635 scopus 로고    scopus 로고
    • High performance cement: A solution for next millennium
    • (1999) Mater. Technol. , vol.14 , Issue.4 , pp. 191-193
  • 27
    • 0032651064 scopus 로고    scopus 로고
    • Effects of ultra-fine materials on workability and strength of concrete containing alkali-activated slag as the binder
    • (1999) Cem. Concr. Res. , vol.29 , Issue.3 , pp. 459-462
    • Collins, F.1    Sanjayan, J.G.2
  • 29
    • 0032658038 scopus 로고    scopus 로고
    • Effect of silica fume and steel fiber on the dynamic mechanical performance of high-strength concrete
    • (1999) Cem. Concr. Res. , vol.29 , Issue.3 , pp. 423-426
    • Yan, H.1    Sun, W.2    Chen, H.3
  • 31
    • 0032677131 scopus 로고    scopus 로고
    • Experimental investigation and theoretical modeling of silica fume activity in concrete
    • (1999) Cem. Concr. Res. , vol.29 , Issue.1 , pp. 79-86
    • Papadakis, V.G.1
  • 32
    • 0033078563 scopus 로고    scopus 로고
    • Durability of reactive powder composites: Influence of silica fume on the leaching properties of very low water/binder pastes
    • (1999) Cem. Concr. Compos. , vol.21 , Issue.1 , pp. 1-9
    • Matte, V.1    Moranville, M.2
  • 35
    • 0001373193 scopus 로고    scopus 로고
    • Uniaxial compression in carbon fiber reinforced cement sensed by electrical resistivity measurement in longitudinal and transverse directions
    • (2001) Cem. Concr. Res. , vol.31 , Issue.2 , pp. 297-301
    • Wen, S.1    Chung, D.D.L.2
  • 36
    • 0034243264 scopus 로고    scopus 로고
    • Uniaxial tension in carbon fiber reinforced cement, sensed by electrical resistivity measurement in longitudinal and transverse directions
    • (2000) Cem. Concr. Res. , vol.30 , Issue.8 , pp. 1289-1294
    • Wen, S.1    Chung, D.D.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.