Volumn 23, Issue 5, 2002, Pages 1283-1293

Mechanical and in vivo performance of hydroxyapatite implants with controlled architectures

Author keywords

Architecture; Hydroxyapatite; In vivo; Mechanical

Indexed keywords

BONE; COMPRESSIVE STRENGTH; HYDROXYAPATITE; POROSITY; POROUS MATERIALS;

EID: 0036498046     PISSN: 01429612     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0142-9612(01)00243-5     Document Type: Article
Times cited : (525)

References (34)
  • 1
    • 0026650338 scopus 로고
    • The critical role of geometry of porous hydroxyapatite delivery system of bone by osteogenin, a bone morphogenic protein
    • (1992) Matrix , vol.12 , pp. 202-212
    • Ripamonti, U.1    Ma, S.2    Reddi, A.3
  • 8
    • 0030104991 scopus 로고    scopus 로고
    • Control of pore geometry on influencing the mechanical property of porous hydroxyapatite bioceramic
    • (1996) J Mater Sci Lett , vol.15 , pp. 419-421
    • Liu, D.1
  • 9
    • 0030783566 scopus 로고    scopus 로고
    • Influence of porosity and pore size on the compressive strength of porous hydroxyapatite ceramic
    • (1997) Ceram Int , vol.23 , pp. 135-139
    • Liu, D.-M.1
  • 12
  • 31
    • 0002692231 scopus 로고
    • The biological profile of hydroxyapatite ceramic with respect to the celluar dynamics of animal and human soft tissue and mineralized tissue under unloaded and loaded conditions
    • Barbosa MA, editor. New York: Elsevier Science Publishers
    • (1991) Biomaterials degradation , pp. 185-225
    • Osborn, J.F.1