Volumn 108 PART 2, Issue , 2002, Pages 1097-1103

Measurement of thermal comfort and local discomfort by a thermal manikin

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; CONTROL SYSTEM ANALYSIS; HEAT LOSSES; HEAT TRANSFER; HEATING EQUIPMENT;

EID: 0036457958     PISSN: 00012505     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (10)

References (13)
  • 2
    • 0010213876 scopus 로고    scopus 로고
    • Dispersal of exhaled air and personal exposure in displacement ventilated rooms
    • Bjoern, E., and P.V. Nielsen. 2001. Dispersal of exhaled air and personal exposure in displacement ventilated rooms. Accepted for publication in Indoor Air 2001.
    • (2001) Indoor Air 2001
    • Bjoern, E.1    Nielsen, P.V.2
  • 4
    • 0004037722 scopus 로고    scopus 로고
    • Malabar, Fla.: Robert E. Krieger Publishing Company
    • Fanger, P.O. 1982. Thermal comfort. Malabar, Fla.: Robert E. Krieger Publishing Company.
    • Thermal comfort , pp. 1982
    • Fanger, P.O.1
  • 5
    • 0012067547 scopus 로고
    • Interinvidual differences in ambient temperature preferred by seated persons
    • Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc
    • Fanger, P.O., and G. Langkilde. 1975. Interinvidual differences in ambient temperature preferred by seated persons. ASHRAE Transactions 81(2):140-47. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • (1975) ASHRAE Transactions , vol.81 , Issue.2 , pp. 140-147
    • Fanger, P.O.1    Langkilde, G.2
  • 10
    • 0012033837 scopus 로고
    • Vertical air temperature differences and comfort
    • P.O. Fanger and O. Valbjoern, eds., Copenhagen: Danish Building Research Institute
    • Olesen, B.W., M. Scholer, and P.O. Fanger. 1979. Vertical air temperature differences and comfort. In Indoor climate, P.O. Fanger and O. Valbjoern, eds., pp. 561-79. Copenhagen: Danish Building Research Institute.
    • (1979) Indoor climate , pp. 561-579
    • Olesen, B.W.1    Scholer, M.2    Fanger, P.O.3
  • 11
    • 0028698624 scopus 로고
    • Evaluating thermal environments by using a thermal manikin with controlled skin surface temperature
    • Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc
    • Tanabe, S., E.E.A. Arens, F.S. Bauman, H. Zhang, and T.L. Madsen. 1994. Evaluating thermal environments by using a thermal manikin with controlled skin surface temperature. ASHRAE Transactions 100 (1): 39-48. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • (1994) ASHRAE Transactions , vol.100 , Issue.1 , pp. 39-48
    • Tanabe, S.1    Arens, E.E.A.2    Bauman, F.S.3    Zhang, H.4    Madsen, T.L.5
  • 12
    • 77953588964 scopus 로고    scopus 로고
    • Effect of airflow direction on human perception of draught
    • Brussels
    • Toftum, J., G. Zhou, and A. Melikov. 1997. Effect of airflow direction on human perception of draught. Clima 2000, Brussels.
    • (1997) Clima 2000
    • Toftum, J.1    Zhou, G.2    Melikov, A.3
  • 13
    • 0003370732 scopus 로고    scopus 로고
    • The impact of airflow directions on the human perception of draught (in Danish)
    • June
    • Toftum, J., A. Melikov, and Z. Genhong. 1999. The impact of airflow directions on the human perception of draught (in Danish). VVS Denmark, June, Vol. 35, No. 8.
    • (1999) VVS Denmark , vol.35 , Issue.8
    • Toftum, J.1    Melikov, A.2    Genhong, Z.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.