메뉴 건너뛰기




Volumn 63, Issue 6, 2002, Pages 739-745

Biaxial flex-fatigue and viral penetration of natural rubber latex gloves before and after artificial aging

Author keywords

Accelerated aging; Fatigue; Flexing; Latex; Viral penetration

Indexed keywords

AGING OF MATERIALS; DEFORMATION; FATIGUE OF MATERIALS; LATEXES; RUBBER; VISCOELASTICITY;

EID: 0036435291     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/jbm.10467     Document Type: Article
Times cited : (17)

References (21)
  • 3
    • 0028495009 scopus 로고
    • A differential air deflation quality assurance test for surgical gloves
    • Carey RF. A differential air deflation quality assurance test for surgical gloves. J Testing Eval 1994;22:442-448.
    • (1994) J Testing Eval , vol.22 , pp. 442-448
    • Carey, R.F.1
  • 4
    • 2242479672 scopus 로고    scopus 로고
    • More stringent testing necessary for medical gloves?
    • Carey RF, Lytle CD. More stringent testing necessary for medical gloves? Rubber Asia 1997;11:69-70.
    • (1997) Rubber Asia , vol.11 , pp. 69-70
    • Carey, R.F.1    Lytle, C.D.2
  • 5
    • 0001925118 scopus 로고
    • Permeability of stressed, surgical latex gloves to HIV
    • Regnault WF, editor. Rockville, MD: U.S. Department of Health and Human Services
    • Goldstein AS, Fleming W, Stokes K. Permeability of stressed, surgical latex gloves to HIV. In: Regnault WF, editor. Latex as a Barrier Material Conference Proceedings. Rockville, MD: U.S. Department of Health and Human Services; 1992. pp 175-184.
    • (1992) Latex as a Barrier Material Conference Proceedings , pp. 175-184
    • Goldstein, A.S.1    Fleming, W.2    Stokes, K.3
  • 6
    • 0025686965 scopus 로고
    • Permeation of cancer chemotherapeutic drugs through glove materials under static and flexed conditions
    • Colligan SA, Horstman SW. Permeation of cancer chemotherapeutic drugs through glove materials under static and flexed conditions. Appl Occup Environ Hyg 1990;5:848-852.
    • (1990) Appl Occup Environ Hyg , vol.5 , pp. 848-852
    • Colligan, S.A.1    Horstman, S.W.2
  • 7
    • 0031117954 scopus 로고    scopus 로고
    • Permeability and material characteristics of vulcanized latex film during and following cyclic fatigue in a saline environment
    • Dillon JG, Schroeder LW. Permeability and material characteristics of vulcanized latex film during and following cyclic fatigue in a saline environment. J Appl Polym Sci 1997;64:553-566.
    • (1997) J Appl Polym Sci , vol.64 , pp. 553-566
    • Dillon, J.G.1    Schroeder, L.W.2
  • 8
    • 0030900730 scopus 로고    scopus 로고
    • The effect of glove flexure on permeation parameters
    • Perkins JL, Rainey KC. The effect of glove flexure on permeation parameters. Appl Occup Environ Hyg 1997;12:206-210.
    • (1997) Appl Occup Environ Hyg , vol.12 , pp. 206-210
    • Perkins, J.L.1    Rainey, K.C.2
  • 10
    • 0000174320 scopus 로고    scopus 로고
    • Ability of a viral penetration test (ASTM F1671-95) to detect small holes
    • Lytle CD, Baker KH. Ability of a viral penetration test (ASTM F1671-95) to detect small holes. J Testing Eval 1999;27:231-233.
    • (1999) J Testing Eval , vol.27 , pp. 231-233
    • Lytle, C.D.1    Baker, K.H.2
  • 12
    • 0000743565 scopus 로고    scopus 로고
    • Modification of ASTM F1671-97a, resistance of materials to penetration by blood-borne pathogens, for use with elastomeric materials
    • Kisielewski RW, Routson LB, Chaput MP, Lytle CD. Modification of ASTM F1671-97a, resistance of materials to penetration by blood-borne pathogens, for use with elastomeric materials. J Testing Eval 2000;28:136-138.
    • (2000) J Testing Eval , vol.28 , pp. 136-138
    • Kisielewski, R.W.1    Routson, L.B.2    Chaput, M.P.3    Lytle, C.D.4
  • 13
    • 0035501155 scopus 로고    scopus 로고
    • An experimental technique for determining biaxial fatigue life-times in biomedical elastomers
    • Long MC, Kisielewski RW, Richardson DC, Schroeder, LW. An experimental technique for determining biaxial fatigue life-times in biomedical elastomers. Int J Fatigue 2001;23:911-916.
    • (2001) Int J Fatigue , vol.23 , pp. 911-916
    • Long, M.C.1    Kisielewski, R.W.2    Richardson, D.C.3    Schroeder, L.W.4
  • 15
    • 0011574896 scopus 로고    scopus 로고
    • Environmental degradation of natural rubber latex gloves: The effects of elevated temperature on tensile strength
    • Walsh DL, Chwirut DJ, Kotz RM. Environmental degradation of natural rubber latex gloves: The effects of elevated temperature on tensile strength. J Testing Eval 1999;27:396-401.
    • (1999) J Testing Eval , vol.27 , pp. 396-401
    • Walsh, D.L.1    Chwirut, D.J.2    Kotz, R.M.3
  • 17
    • 0033648733 scopus 로고    scopus 로고
    • Efficacy of protection by latex gloves during orthodontic therapy
    • Doll GM, Zentner A, Balan R, Sergl HG. Efficacy of protection by latex gloves during orthodontic therapy. J Orofac Orthop 2000;61:80-90.
    • (2000) J Orofac Orthop , vol.61 , pp. 80-90
    • Doll, G.M.1    Zentner, A.2    Balan, R.3    Sergl, H.G.4
  • 21
    • 0003006351 scopus 로고    scopus 로고
    • Lack of latex porosity: A review of virus barrier tests
    • Lytle CD, Routson LB. Lack of latex porosity: A review of virus barrier tests. J Rubber Res 1999;2:29-39.
    • (1999) J Rubber Res , vol.2 , pp. 29-39
    • Lytle, C.D.1    Routson, L.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.