메뉴 건너뛰기




Volumn 4611, Issue , 2002, Pages 129-135

In-the-spectacle-lens telescopic device for low vision

Author keywords

Bioptic telescope; Optical visual aid; Visual multiplexing

Indexed keywords

COMPUTER SIMULATION; MIRRORS; MULTIPLEXING; OPTICAL INSTRUMENT LENSES; VISION AIDS;

EID: 0036401983     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.470586     Document Type: Conference Paper
Times cited : (6)

References (12)
  • 3
    • 0025718287 scopus 로고
    • The BITA telescope: A first impression
    • T. Harkins, "The BITA telescope: a first impression," JAOA; 62, pp. 28-31, 1991.
    • (1991) JAOA , vol.62 , pp. 28-31
    • Harkins, T.1
  • 4
    • 0024420322 scopus 로고
    • Behind the lens telescope: A new concept in bioptics
    • L. Spitzberg, R.T. Jose, and C.L. Kuether, "Behind the lens telescope: A new concept in bioptics," Optom Vis Sci; 66, pp. 616-620, 1989.
    • (1989) Optom Vis Sci , vol.66 , pp. 616-620
    • Spitzberg, L.1    Jose, R.T.2    Kuether, C.L.3
  • 5
    • 0025717532 scopus 로고
    • The Ocutech vision enhancing system (VES): Utilization and preference study
    • H.A. Greene and et al., "The Ocutech vision enhancing system (VES): Utilization and preference study," JAOA; 62, pp. 19-27, 1991.
    • (1991) JAOA , vol.62 , pp. 19-27
    • Greene, H.A.1
  • 6
    • 0000300201 scopus 로고
    • Clinical experience with the contact lens telescope
    • W.M. Ludlam, "Clinical experience with the contact lens telescope," Am J Optom; 37, pp. 363-372, 1960.
    • (1960) Am J Optom , vol.37 , pp. 363-372
    • Ludlam, W.M.1
  • 7
    • 0024917652 scopus 로고
    • Preliminary evaluation of the Koziol-Peyman teledioptric system for age-related macular degeneration
    • T.R. Willis and V. Portney, "Preliminary evaluation of the Koziol-Peyman teledioptric system for age-related macular degeneration," European Journal of Implant Refractive Surgery; 1, pp. 271-276, 1989.
    • (1989) European Journal of Implant Refractive Surgery , vol.1 , pp. 271-276
    • Willis, T.R.1    Portney, V.2
  • 8
    • 0001192208 scopus 로고
    • The contact lens for subnormal visual acuity
    • L. Moore, "The contact lens for subnormal visual acuity," British Journal of Physiological Optics; 21, pp. 203-204, 1964.
    • (1964) British Journal of Physiological Optics , vol.21 , pp. 203-204
    • Moore, L.1
  • 9
    • 0002714385 scopus 로고    scopus 로고
    • Implantable miniaturized telescope (IMT) for low vision
    • Stuen C., Arditi A., Horowitz A., Lang M.A., Rosenthal B., Seidman K., eds. Swets & Zeitlinger, Lisse
    • E. Peli, I. Lipshitz, and G. Dotan. "Implantable miniaturized telescope (IMT) for low vision." In: Vision Rehabilitation: Assessment, Intervention and Outcomes. Stuen C., Arditi A., Horowitz A., Lang M.A., Rosenthal B., Seidman K., eds. pp. 200-203, Swets & Zeitlinger, Lisse, 2000.
    • (2000) Vision Rehabilitation: Assessment, Intervention and Outcomes , pp. 200-203
    • Peli, E.1    Lipshitz, I.2    Dotan, G.3
  • 10
    • 0011017935 scopus 로고
    • Nondispersive prisms
    • Bass M., van Stryland E.W., Williams D.R., Wolfe WI, eds., McGraw Hill, New York
    • W.B. Wolfe. "Nondispersive Prisms", In: The Handbook of Optics. Bass M., van Stryland E.W., Williams D.R., Wolfe WI, eds. vol II), pp. 4.1-29, McGraw Hill, New York, 1994.
    • (1994) The Handbook of Optics , vol.2 , pp. 41-29
    • Wolfe, W.B.1
  • 11
    • 0035001265 scopus 로고    scopus 로고
    • Vision multiplexing: An engineering approach to vision rehabilitation device development
    • E. Peli, "Vision multiplexing: an engineering approach to vision rehabilitation device development," Optom Vis Sci; 78, pp. 304-15., 2001.
    • (2001) Optom Vis Sci , vol.78 , pp. 304-315
    • Peli, E.1
  • 12
    • 0011058568 scopus 로고
    • Edwards Optical Corporation
    • BITA Reference Manual. Edwards Optical Corporation, 1989.
    • (1989) BITA Reference Manual


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.