메뉴 건너뛰기




Volumn 48, Issue 9-10, 2002, Pages 535-540

The measurement of theophylline in human serum or plasma using gas chromatography and isotope dilution-mass spectrometry (GC-IDMS) taking other substituted xanthines into consideration

Author keywords

Caffeine; Gas chromatography; Human serum; Isotope dilution; Mass spectrometry; Paraxanthine; Theobromine; Theophylline; Xanthines

Indexed keywords

1,3 DIMETHYL 7 (2 HYDROXYETHYL) XANTHINE; ACETAMIDE DERIVATIVE; BETA HYDROXY THEOPHYLLINE; CAFFEINE; N METHYL N TRIMETHYLSILYL TRIFLUOROACETAMIDE; PARAXANTHINE; THEOBROMINE; THEOPHYLLINE; THEOPHYLLINE DERIVATIVE; UNCLASSIFIED DRUG; XANTHINE DERIVATIVE;

EID: 0036398572     PISSN: 14336510     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (8)
  • 1
    • 0001572240 scopus 로고    scopus 로고
    • Richtlinie der Bundesärztekammer zur Qualitätssicherung quantitativer laboratoriumsmedizinischer Untersuchungen - Beschluss des Vorstands der Bundesärztekammer vom 24
    • August 2001
    • Richtlinie der Bundesärztekammer zur Qualitätssicherung quantitativer laboratoriumsmedizinischer Untersuchungen - Beschluss des Vorstands der Bundesärztekammer vom 24. August 2001. Deutsches Ärzteblatt 98; 2001: B2356-67
    • (2001) Deutsches Ärzteblatt , vol.98
  • 2
    • 0003179886 scopus 로고
    • Neue Richtlinien der Bundesärztekammer
    • Qualitätssicherung der quantitativen Bestimmungen im Laboratorium
    • Qualitätssicherung der quantitativen Bestimmungen im Laboratorium. Neue Richtlinien der Bundesärztekammer. Deutsches Ärzteblatt 85; 1988: A697-712
    • (1988) Deutsches Ärzteblatt , vol.85
  • 3
    • 0036400039 scopus 로고    scopus 로고
    • Determination of Theophylline by HPLC and GC-IDMS, the Effect of Chemically Similar Xanthine Derivastes on the Specificity of the Method and the Possibility of Paracetamol as Interfering Substance
    • Kress M, Meissner D, Hanke R, Wood WG. Determination of Theophylline by HPLC and GC-IDMS, the Effect of Chemically Similar Xanthine Derivastes on the Specificity of the Method and the Possibility of Paracetamol as Interfering Substance. Clin Lab. 2002;48:541-551
    • (2002) Clin. Lab , vol.48 , pp. 541-551
    • Kress, M.1    Meissner, D.2    Hanke, R.3    Wood, W.G.4
  • 4
    • 0021742378 scopus 로고
    • Automated theophylline assay using gas chromatography and a mass-selective detector
    • Desage M, Soubeyrand J, Soun A, Brazier JL, Georges Y. Automated theophylline assay using gas chromatography and a mass-selective detector. J Chromatogr. 33; 1984: 285-91
    • (1984) J. Chromatogr , vol.33 , pp. 285-291
    • Desage, M.1    Soubeyrand, J.2    Soun, A.3    Brazier, J.L.4    Georges, Y.5
  • 5
    • 0028141441 scopus 로고
    • Candidate reference method for determining serum theophylline applied to target-setting in external quality assessment and routine method evaluation
    • Thienpont LM, van Neuwenhove B, Stöckl D, de Leenheer AP. Candidate reference method for determining serum theophylline applied to target-setting in external quality assessment and routine method evaluation. Clin Chem. 40; 1994: 1503-11
    • (1994) Clin. Chem , vol.40 , pp. 1503-1511
    • Thienpont, L.M.1    van Neuwenhove, B.2    Stöckl, D.3    de Leenheer, A.P.4
  • 6
    • 0029846261 scopus 로고    scopus 로고
    • Determination of reference method values by isotope dilution gas-chromatography/mass spectrometry: A five years' experience of two European Reference Laboratories
    • Thienpont LM, van Neuwenhove B, Stöckl D, Reinauer H, de Leenheer AP. Determination of reference method values by isotope dilution gas-chromatography/mass spectrometry: a five years' experience of two European Reference Laboratories. Eur J Clin Chem Clin Biochem. 34; 1996: 853-60
    • (1996) Eur. J. Clin. Chem. Clin. Biochem , vol.34 , pp. 853-860
    • Thienpont, L.M.1    van Neuwenhove, B.2    Stöckl, D.3    Reinauer, H.4    de Leenheer, A.P.5
  • 7
  • 8
    • 0022637561 scopus 로고
    • Comparison between theophylline analysis by nephelometric inhibition immunoassay and high performance liquid chromatography
    • Mordelet-Dambrine M, Baglin JY, Roux A, Dusser D, Flouvat B, Huchon G. Comparison between theophylline analysis by nephelometric inhibition immunoassay and high performance liquid chromatography. Ther Drug Monit. 8; 1986: 106-110
    • (1986) Ther. Drug Monit , vol.8 , pp. 106-110
    • Mordelet-Dambrine, M.1    Baglin, J.Y.2    Roux, A.3    Dusser, D.4    Flouvat, B.5    Huchon, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.