메뉴 건너뛰기




Volumn 63, Issue 5, 2002, Pages 664-670

The electrochemical behavior of Ti-6Al-7Nb alloy with and without plasma-sprayed hydroxyapatite coating in Hank's solution

Author keywords

Biomaterial; Corrosion; Dental implant; Hydroxyapatite; Titanium alloy

Indexed keywords

COATINGS; CURRENT DENSITY; POLARIZATION; SALTS;

EID: 0036381599     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/jbm.10351     Document Type: Article
Times cited : (50)

References (15)
  • 1
    • 0032212195 scopus 로고    scopus 로고
    • Interfacial characterization of plasma-spray coated calcium phosphate on Ti-6Al-4V
    • Park E, Condrate Sr. R A, Hoelzer DT, Fischman GS. Interfacial characterization of plasma-spray coated calcium phosphate on Ti-6Al-4V. J Mater Sci Mater Med 1998;9:643-649.
    • (1998) J Mater Sci Mater Med , vol.9 , pp. 643-649
    • Park, E.1    Condrate R.A., Sr.2    Hoelzer, D.T.3    Fischman, G.S.4
  • 2
    • 0031104959 scopus 로고    scopus 로고
    • Mechanical and chemical consequences of the residual stresses in plasma sprayed hydroxyapatite coatings
    • Sergo V, Sbaizero O, Clarke DR. Mechanical and chemical consequences of the residual stresses in plasma sprayed hydroxyapatite coatings. Biomaterials 1997;18:477-482.
    • (1997) Biomaterials , vol.18 , pp. 477-482
    • Sergo, V.1    Sbaizero, O.2    Clarke, D.R.3
  • 3
    • 0035097585 scopus 로고    scopus 로고
    • A study of histological responses from Ti-6Al-7Nb alloy dental implants with and without plasma-sprayed hydroxyapatite coating in dogs
    • Lavos-Valereto IC, König Jr. B, Rossa Jr. C, Marcantonio Jr. E, Zavaglia AC. A study of histological responses from Ti-6Al-7Nb alloy dental implants with and without plasma-sprayed hydroxyapatite coating in dogs. J Mater Sci Mater Med 2001;12:273-276.
    • (2001) J Mater Sci Mater Med , vol.12 , pp. 273-276
    • Lavos-Valereto, I.C.1    König B., Jr.2    Rossa C., Jr.3    Marcantonio E., Jr.4    Zavaglia, A.C.5
  • 4
    • 0031359947 scopus 로고    scopus 로고
    • Electrochemical behaviour of hydroxyapatite-coated stainless steel implants
    • Sridhar TM, Arumugam TK, Rajeswari S, Subbaiyan M. Electrochemical behaviour of hydroxyapatite-coated stainless steel implants. J Mater Sci Lett 1997;16:1964-1966.
    • (1997) J Mater Sci Lett , vol.16 , pp. 1964-1966
    • Sridhar, T.M.1    Arumugam, T.K.2    Rajeswari, S.3    Subbaiyan, M.4
  • 5
    • 0025315707 scopus 로고
    • Calcium phosphate ceramic coatings on porous titanium: Effect of structure and composition on electrophoretic deposition, vacuum sintering and in vitro dissolution
    • Ducheyne P, Radin S, Heughebaert M, Heughebaert JC. Calcium phosphate ceramic coatings on porous titanium: Effect of structure and composition on electrophoretic deposition, vacuum sintering and in vitro dissolution. Biomaterials 1990;11:244-254.
    • (1990) Biomaterials , vol.11 , pp. 244-254
    • Ducheyne, P.1    Radin, S.2    Heughebaert, M.3    Heughebaert, J.C.4
  • 7
    • 0030087995 scopus 로고    scopus 로고
    • The effect of hydroxyapatite thickness on metal ion release from Ti6Al4V substrates
    • Sousa SR, Barbosa MA. The effect of hydroxyapatite thickness on metal ion release from Ti6Al4V substrates. Biomaterials 1996;17:397-404.
    • (1996) Biomaterials , vol.17 , pp. 397-404
    • Sousa, S.R.1    Barbosa, M.A.2
  • 8
    • 0031172803 scopus 로고    scopus 로고
    • Effect of different surface finishing and of hydroxyapatite coatings on passive and corrosion current of Ti6Al4V alloy in simulated physiological solution
    • Cabrini M, Cigada A, Rondelli G, Vicentini B. Effect of different surface finishing and of hydroxyapatite coatings on passive and corrosion current of Ti6Al4V alloy in simulated physiological solution. Biomaterials 1997;18:783-787.
    • (1997) Biomaterials , vol.18 , pp. 783-787
    • Cabrini, M.1    Cigada, A.2    Rondelli, G.3    Vicentini, B.4
  • 9
    • 0031080821 scopus 로고    scopus 로고
    • Investigation of the dissolution of the bioceramic hydroxyapatite in the presence of titanium ions using ToF-SIMS and XPS
    • Leadley SR, Davies MC, Ribeiro CC, Barbosa MA, Paul AJ, Watts JF. Investigation of the dissolution of the bioceramic hydroxyapatite in the presence of titanium ions using ToF-SIMS and XPS. Biomaterials 1997;18:311-316.
    • (1997) Biomaterials , vol.18 , pp. 311-316
    • Leadley, S.R.1    Davies, M.C.2    Ribeiro, C.C.3    Barbosa, M.A.4    Paul, A.J.5    Watts, J.F.6
  • 10
    • 0345504724 scopus 로고    scopus 로고
    • Study of the corrosion behavior of titanium and some of its alloys for biomedical and dental implant applications
    • González JEG, Mirza-Rosca JC. Study of the corrosion behavior of titanium and some of its alloys for biomedical and dental implant applications. J Electroanal Chem 1999;471:109-115.
    • (1999) J Electroanal Chem , vol.471 , pp. 109-115
    • González, J.E.G.1    Mirza-Rosca, J.C.2
  • 11
    • 0035178251 scopus 로고    scopus 로고
    • In vitro and in vivo biocompatibility testing of Ti-6Al-7Nb alloy with and without plasma-sprayed hydroxyapatite coating
    • Lavos-Valereto IC, Wolynec S, Deboni MCZ, König Jr. B. In vitro and in vivo biocompatibility testing of Ti-6Al-7Nb alloy with and without plasma-sprayed hydroxyapatite coating. J Biomed Mater Res 2001;58:727-733.
    • (2001) J Biomed Mater Res , vol.58 , pp. 727-733
    • Lavos-Valereto, I.C.1    Wolynec, S.2    Deboni, M.C.Z.3    König B., Jr.4
  • 12
    • 0020128343 scopus 로고
    • Electrochemical behavior of passive layers on titanium
    • El-Basiouny MS, Mazhar AA. Electrochemical behavior of passive layers on titanium. Corrosion 1982;38:237-240.
    • (1982) Corrosion , vol.38 , pp. 237-240
    • El-Basiouny, M.S.1    Mazhar, A.A.2
  • 13
    • 0031226075 scopus 로고    scopus 로고
    • Passive film growth on titanium alloys: Physicochemical and biologic considerations
    • Eliades T. Passive film growth on titanium alloys: Physicochemical and biologic considerations. Int J Oral Maxillofac Implants 1997;12:621-627.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 621-627
    • Eliades, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.