Volumn 3, Issue 1, 2002, Pages 49-56

The Quality of Reconstructed 3D Images in Multidetector-Row Helical CT: Experimental Study Involving Scan Parameters

Author keywords

Computed tomography (CT), experimental study; Computed tomography (CT), helical; Computed tomography (CT), three dimensional

Indexed keywords

ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; HUMAN; IMAGE PROCESSING; THREE DIMENSIONAL IMAGING;

EID: 0036371837     PISSN: 12296929     EISSN: None     Source Type: Journal    
DOI: 10.3348/kjr.2002.3.1.49     Document Type: Article
Times cited : (9)

References (18)
  • 1
    • 0025351273 scopus 로고
    • Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation
    • Kalender WA, Seissler W, Klotz E, Vock P. Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. Radiology 1990;176:181-183
    • (1990) Radiology , vol.176 , pp. 181-183
    • Kalender, W.A.1    Seissler, W.2    Klotz, E.3    Vock, P.4
  • 2
    • 0025221610 scopus 로고
    • Computed tomography scanning with simultaneous patient translation
    • Crawford CR, King KF. Computed tomography scanning with simultaneous patient translation. Med Phys 1990;17:967-982
    • (1990) Med Phys , vol.17 , pp. 967-982
    • Crawford, C.R.1    King, K.F.2
  • 4
    • 0026048199 scopus 로고
    • Physical performance characteristics of spiral CT scanning
    • Kalender WA, Polacin A. Physical performance characteristics of spiral CT scanning. Med Phys 1991;18:910-915
    • (1991) Med Phys , vol.18 , pp. 910-915
    • Kalender, W.A.1    Polacin, A.2
  • 5
    • 0030066343 scopus 로고    scopus 로고
    • Dual-slice spiral versus single-slice spiral scanning: Comparison of the physical performance of two computed tomography scanners
    • Liang Y, Kruger RA. Dual-slice spiral versus single-slice spiral scanning: comparison of the physical performance of two computed tomography scanners. Med Phys 1996;23:205-220
    • (1996) Med Phys , vol.23 , pp. 205-220
    • Liang, Y.1    Kruger, R.A.2
  • 6
    • 0031757970 scopus 로고    scopus 로고
    • Liver lesions: Improved detection with dual-detector-array CT and routine 2.5-mm thin collimation
    • Weg N, Scheer MR, Gabor MP. Liver lesions: improved detection with dual-detector-array CT and routine 2.5-mm thin collimation. Radiology 1998;209:417-426
    • (1998) Radiology , vol.209 , pp. 417-426
    • Weg, N.1    Scheer, M.R.2    Gabor, M.P.3
  • 7
    • 0032924568 scopus 로고    scopus 로고
    • Multi-slice helical CT: Scan and reconstruction
    • Hu H. Multi-slice helical CT: scan and reconstruction. Med Phys 1999;26:5-18
    • (1999) Med Phys , vol.26 , pp. 5-18
    • Hu, H.1
  • 8
    • 0031956821 scopus 로고    scopus 로고
    • Algorithm for image reconstruction in multi-slice helical CT
    • Taguchi K. Aradate H. Algorithm for image reconstruction in multi-slice helical CT. Med Phys 1998;25:550-561
    • (1998) Med Phys , vol.25 , pp. 550-561
    • Taguchi, K.1    Aradate, H.2
  • 9
    • 0034069213 scopus 로고    scopus 로고
    • Multidetector-row helical CT: Image quality and volume coverage speed
    • Hu H, He HD, Foley WD, Fox SH. Multidetector-row helical CT: image quality and volume coverage speed. Radiology 2000;215:55-62
    • (2000) Radiology , vol.215 , pp. 55-62
    • Hu, H.1    He, H.D.2    Foley, W.D.3    Fox, S.H.4
  • 10
    • 0026055122 scopus 로고
    • Three-dimensional volumetric display of CT data: Effect of scan parameters upon image quality
    • Ney DR, Fishman EK, Magid D, Robertson DD, Kawashima A. Three-dimensional volumetric display of CT data: effect of scan parameters upon image quality. J Comput Assist Tomogr 1991;15:875-885
    • (1991) J Comput Assist Tomogr , vol.15 , pp. 875-885
    • Ney, D.R.1    Fishman, E.K.2    Magid, D.3    Robertson, D.D.4    Kawashima, A.5
  • 11
    • 0026457176 scopus 로고
    • Comparison of helical and serial CT with regard to three-dimensional imaging of musculoskeletal anatomy
    • Ney DR, Fishman EK, Kawashima A, Robertson DD Jr, Scott WW. Comparison of helical and serial CT with regard to three-dimensional imaging of musculoskeletal anatomy. Radiology 1992;185:865-869
    • (1992) Radiology , vol.185 , pp. 865-869
    • Ney, D.R.1    Fishman, E.K.2    Kawashima, A.3    Robertson Jr., D.D.4    Scott, W.W.5
  • 12
    • 0028912092 scopus 로고
    • Reconstructed helical CT scans: Improvement in z-axis resolution compared with overlapped and nonoverlapped conventional CT scans
    • Kasales CJ, Hopper KD, Ariola DN, et al. Reconstructed helical CT scans: improvement in z-axis resolution compared with overlapped and nonoverlapped conventional CT scans. AJR 1995;164:1281-1284
    • (1995) AJR , vol.164 , pp. 1281-1284
    • Kasales, C.J.1    Hopper, K.D.2    Ariola, D.N.3
  • 13
    • 0031028774 scopus 로고    scopus 로고
    • Multiplanar image reconstruction and 3D imaging using a musculoskeletal phantom: Conventional versus helical CT
    • Kasales CJ, Mauger DT, Sefczek RJ, et al. Multiplanar image reconstruction and 3D imaging using a musculoskeletal phantom: conventional versus helical CT. J Comput Assist Tomogr 1997;21:162-169
    • (1997) J Comput Assist Tomogr , vol.21 , pp. 162-169
    • Kasales, C.J.1    Mauger, D.T.2    Sefczek, R.J.3
  • 14
    • 9544238085 scopus 로고    scopus 로고
    • The quality of 3D reconstructions from 1.0 and 1.5 pitch helical and conventional CT
    • Hopper KD, Pierantozzi D, Potok PS, et al. The quality of 3D reconstructions from 1.0 and 1.5 pitch helical and conventional CT. J Comput Assist Tomogr 1996;20:841-847
    • (1996) J Comput Assist Tomogr , vol.20 , pp. 841-847
    • Hopper, K.D.1    Pierantozzi, D.2    Potok, P.S.3
  • 15
    • 0028298099 scopus 로고
    • A comparison of conventional and spiral CT: An experimental study on the detection of spherical lesions
    • Kalender WA, Polacin A, Suss C. A comparison of conventional and spiral CT: an experimental study on the detection of spherical lesions. J Comput Assist Tomogr 1994;18:167-176
    • (1994) J Comput Assist Tomogr , vol.18 , pp. 167-176
    • Kalender, W.A.1    Polacin, A.2    Suss, C.3
  • 16
    • 0028124280 scopus 로고
    • Comparison of spiral computed tomography versus conventional computed tomography multiplanar reconstructions of a fracture displacement phantom
    • McEnery KW, Wilson AJ, Murphy WA Jr. Comparison of spiral computed tomography versus conventional computed tomography multiplanar reconstructions of a fracture displacement phantom. Invest Radiol 1994;29:665-670
    • (1994) Invest Radiol , vol.29 , pp. 665-670
    • McEnery, K.W.1    Wilson, A.J.2    Murphy Jr., W.A.3
  • 17
    • 0034989937 scopus 로고    scopus 로고
    • Multislice helical CT of focal and diffuse lung disease: Comprehensive diagnosis with reconstruction of contiguous and high-resolution CT sections from a single thin-collimation scan
    • Schoepf UJ, Bruening RD, Hong C, et al. Multislice helical CT of focal and diffuse lung disease: comprehensive diagnosis with reconstruction of contiguous and high-resolution CT sections from a single thin-collimation scan. AJR 2001;177:179-184
    • (2001) AJR , vol.177 , pp. 179-184
    • Schoepf, U.J.1    Bruening, R.D.2    Hong, C.3
  • 18
    • 0035459697 scopus 로고    scopus 로고
    • Multi-detector row CT of thoracic disease with emphasis on 3D volume rendering and CT angiography
    • Lawler LP, Fishman EK. Multi-detector row CT of thoracic disease with emphasis on 3D volume rendering and CT angiography. RadioGraphics 2001;21:1257-1273
    • (2001) RadioGraphics , vol.21 , pp. 1257-1273
    • Lawler, L.P.1    Fishman, E.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.