Volumn 68, Issue 6, 2002, Pages 2711-2715
|
Negative effect of high pH on biocidal efficacy of copper and silver ions in controlling Legionella pneumophila
a a a a |
Author keywords
[No Author keywords available]
|
Indexed keywords
COPPER;
HOSPITALS;
HOT WATER DISTRIBUTION SYSTEMS;
IONIZATION;
PH EFFECTS;
POSITIVE IONS;
SILVER;
BIOCIDAL EFFICACY;
WATER QUALITY;
BICARBONATE;
CALCIUM ION;
CARBON;
COPPER ION;
DISSOLVED ORGANIC MATTER;
HOT WATER;
MAGNESIUM;
SILVER;
MICROBIOLOGY;
ALKALINITY;
ARTICLE;
BACTERICIDAL ACTIVITY;
COLONY FORMING UNIT;
COMPLEX FORMATION;
CONCENTRATION RESPONSE;
CONTROLLED STUDY;
HOSPITAL;
HOSPITAL INFECTION;
INFECTION CONTROL;
IONIZATION;
LEGIONELLA PNEUMOPHILA;
NONHUMAN;
PH;
REDUCTION;
WATER HARDNESS;
WATER QUALITY;
BICARBONATES;
CHLORIDES;
COPPER;
HYDROGEN-ION CONCENTRATION;
LEGIONELLA PNEUMOPHILA;
MICROBIAL SENSITIVITY TESTS;
MODELS, BIOLOGICAL;
SILVER;
LEGIONELLA;
LEGIONELLA PNEUMOPHILA;
NEGIBACTERIA;
|
EID: 0036273107
PISSN: 00992240
EISSN: None
Source Type: Journal
DOI: 10.1128/AEM.68.6.2711-2715.2002 Document Type: Article |
Times cited : (93)
|
References (14)
|