-
1
-
-
0023000308
-
Closed-chest atrioventricular junction ablation by high-frequency energy transcatheter desiccation
-
(1986)
Lancet
, vol.2
, pp. 858-859
-
-
Lavergne, T.1
-
4
-
-
0030966403
-
Subendacardial and intramural temperature response during radiofrequency catheter ablation in chronic myocardial infarction and normal myacardium
-
(1997)
Circulation
, vol.95
, pp. 2155-2161
-
-
Kottkamp, H.1
-
5
-
-
0025793953
-
Catheter ablation of atrioventricular junction using radiofrequency current in 17 patients. Comparison of standard and large-tip catheter electrodes
-
(1991)
Circulation
, vol.83
, pp. 1562-1576
-
-
Jackman, W.M.1
-
8
-
-
0028240838
-
Effects of radiofrequency catheter ablation on regional myocardial blood flaw. Possible mechanism far late electrophysiogical outcome
-
(1994)
Circulation
, vol.89
, pp. 2667-2672
-
-
Nath, S.1
-
9
-
-
15444359497
-
Why a large tip electrode makes a deeper radiofrequency lesion: Effects of increase in electrode coolling and electrode-tissue interface areo
-
(1998)
J Cordiovasc Electrophysiol
, vol.9
, pp. 47-54
-
-
Otomo, K.1
-
10
-
-
0030686445
-
Non-uniform heating during radiofrequency catheter ablation with long electrodes. Monitoring the edge effect
-
(1997)
Circulation
, vol.96
, pp. 4057-4064
-
-
McRury, I.D.1
-
11
-
-
0008906791
-
Ablation of typical flutter. Is the cooled electrode superior to the 4 mm and the 8 mm ablation electrode
-
(2001)
PACE
, vol.24
, pp. 724
-
-
Weismueller, P.1
-
13
-
-
0028942447
-
Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation
-
(1995)
Circulation
, vol.91
, pp. 2264-2273
-
-
Nakagawa, H.1
-
14
-
-
0008933422
-
Highly sensitive impedance monitoring may predict electrode contact pressure and lesion size during radiofrequency ablation using a saline irrigated catheter
-
(2001)
PACE
, vol.24
, pp. 610
-
-
Matsudera, K.1
-
15
-
-
0034700269
-
Efficacy and safety of an irrigated-tip catheter far the ablation of accessory pathways resistant to conventional radiofrequency ablation
-
(2000)
Circulation
, vol.102
, pp. 2565-2568
-
-
Yamane, T.1
-
16
-
-
0035836538
-
Saline-cooled versus standard radiofrequency catheter ablation for infarct-related ventricular tachycardias
-
(2001)
Circulation
, vol.103
, pp. 1858-1862
-
-
Soejima, K.1
-
17
-
-
0032483049
-
Inverse relationship between electrode size and lesion size during radiofrequency ablation with active electrode coaling
-
(1998)
Circulation
, vol.98
, pp. 458-465
-
-
Nakagawa, H.1
-
18
-
-
0008957623
-
Assessment of electrophysiologic endpoints during phased radiofrequency lineor catheter ablation
-
(2001)
PACE
, vol.24
, pp. 691
-
-
Sanchez, J.E.1
-
19
-
-
4243414207
-
Pulsed radiofrequency energy and multi-electrode catheters: Comparison of two different monitoring modes for ablation of porcine right atrium
-
(2001)
Eur Heart J
, vol.37
-
-
Kongsgoord, E.1
-
20
-
-
4243617236
-
Prospective randomized comparison of pulsed and continuous energy delivery in catheter oblation of common atrial flutter
-
(2001)
Eur Heart J
, vol.37
-
-
Erdogan, A.1
-
21
-
-
0032480265
-
Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins
-
(1998)
N Engl J Med
, vol.339
, pp. 659-666
-
-
Haïssaguerre, M.1
-
22
-
-
0008952631
-
Safety of a curvilinear irrigated ablation catheter
-
(2000)
PACE
, vol.23
-
-
Lavergne, T.1
-
23
-
-
0008936071
-
A novel expendoble mesh electrodes for mapping and radiofrequency oblation of pulmonary vein ostia
-
(2000)
PACE
, vol.24
, pp. 633
-
-
Arruda, M.S.1
-
24
-
-
0008886205
-
Circumferential ablation in vivo in cardiac tissue with a new microporus balloon catheter
-
(2001)
PACE 2001
, pp. 542
-
-
Arentz, T.1
-
27
-
-
0026342042
-
Catheter ablation of the atrioventricular junction using a helical microwave antenna: A novel means of coupling energy to the endocardium
-
(1991)
Pacing Clin Electrophysiol
, vol.14
, pp. 2105-2113
-
-
Langberg, J.J.1
-
28
-
-
0029088427
-
Application of ultrasound energy for intracardiac ablation of arrhythmias
-
(1995)
Eur Heart J
, vol.16
, pp. 961-966
-
-
He, D.S.1
-
29
-
-
0008952633
-
Feasibility, and safety of using a larger balloon catheter and higher power for ultrasound ablation of pulmonary vein ostia
-
(2001)
PACE
, vol.24
, pp. 633
-
-
Arruda, M.S.1
-
30
-
-
0034680347
-
First human experience with pulmonary vein isolation using a through-the-balloon circumferential ultrasound ablation system for recurrent atrial fibrillation
-
(2000)
Circulation
, vol.102
, pp. 1879-1882
-
-
Natale, A.1
-
31
-
-
0021998737
-
Laser catheter-induced atrioventricular nodal delays and atrioventricular block in dogs: Acute and chronic observations
-
(1985)
J Am Coll Cardiol
, vol.5
, pp. 259-267
-
-
Narula, O.S.1
-
32
-
-
4243390409
-
Fiberoptic balloon catheter ablation of pulmonary vein ostia in pigs using phatonic energy delivery with diode laser
-
(2001)
Eur Heart J
, vol.37
-
-
Lemery, R.1
-
36
-
-
0034610437
-
Cryothermal ablation of the slow pathway for the elimination of atrioventricular nodal reentrant tachycardia
-
(2000)
Circulation
, vol.102
, pp. 2856-2860
-
-
Skanes, A.C.1
-
37
-
-
0008942745
-
New cryo balloon technology for the electrical isolation of the pulmonary veins
-
(2001)
PACE
, vol.24
, pp. 542
-
-
Avitall, B.1
-
38
-
-
0001555601
-
New cryo technology for creation of long contiguous linear lesions: Comparison with radiofrequency ablation on left atrial mechanics and lesion morphology
-
(2001)
PACE
, vol.24
, pp. 610
-
-
Avitall, B.1
|