메뉴 건너뛰기




Volumn 124, Issue 1, 2002, Pages 47-55

Performance evaluation of a window room air conditioner with microchannel condensers

Author keywords

[No Author keywords available]

Indexed keywords

CALORIMETERS; COMPUTER SIMULATION; CONDENSERS (LIQUEFIERS); ENERGY EFFICIENCY; HEAT EXCHANGERS; HEAT TRANSFER; MATHEMATICAL MODELS; PRESSURE DROP; REFRIGERANTS; TEMPERATURE;

EID: 0036233470     PISSN: 01950738     EISSN: None     Source Type: Journal    
DOI: 10.1115/1.1446072     Document Type: Article
Times cited : (42)

References (18)
  • 6
    • 0032667327 scopus 로고    scopus 로고
    • Effect of strip location on the air-side pressure drop and heat transfer in strip fin-and-tube heat exchangers
    • (1999) Int. J. Refrig. , vol.22 , pp. 302-312
    • Kang, H.C.1    Kim, M.H.2
  • 11
    • 0004332092 scopus 로고    scopus 로고
    • Modeling, design, testing of a microchannel split-system air conditioner
    • ACRC TR-49, University of Illinois at Urbana-Champaign
    • (1999)
    • Kirkwood, A.C.1    Bullard, C.W.2
  • 14
    • 0003501549 scopus 로고
    • Computer modeling and prediction of performance of an air source heat pump with a capillary tube
    • Ph.D. thesis, The Catholic University of America, Washington, DC
    • (1982)
    • Domanski, P.A.1