메뉴 건너뛰기




Volumn 7, Issue 4, 2002, Pages 271-278

Staging of regional nodes in AJCC stage I and II melanoma: 18FDG PET imaging versus sentinel node detection

Author keywords

18FDG PET; Cutaneous melanoma; Lymphatic mapping; Sentinel node

Indexed keywords

FLUORODEOXYGLUCOSE F 18; LYMPHOSCINT; TECHNETIUM SULFUR COLLOID TC 99M;

EID: 0036058601     PISSN: 10837159     EISSN: None     Source Type: Journal    
DOI: 10.1634/theoncologist.7-4-271     Document Type: Article
Times cited : (89)

References (41)
  • 3
    • 0023861022 scopus 로고
    • The role of elective lymph node dissection in melanoma: Rationale, results, and controversies
    • (1988) J Clin Oncol , vol.6 , pp. 163-172
    • Balch, C.M.1
  • 7
    • 0033497863 scopus 로고    scopus 로고
    • Validation of the accuracy of intraoperative lymphatic mapping and sentinel lymphadenectomy for early-stage melanoma: A multicenter trial
    • Multicenter Selective Lymphadenectomy Trial Group
    • (1999) Ann Surg , vol.230 , pp. 453-463
    • Morton, D.L.1    Thompson, J.F.2    Essner, R.3
  • 8
    • 0034662291 scopus 로고    scopus 로고
    • The Augsburg Consensus. Techniques of lymphatic mapping, sentinel lymphadenectomy, and completion lymphadenectomy in cutaneous malignancies
    • (2000) Cancer , vol.89 , pp. 236-241
    • Cochran, A.J.1    Balda, B.R.2    Starz, H.3
  • 9
    • 0034778751 scopus 로고    scopus 로고
    • Lymphatic mapping and sentinel lymphadenectomy for melanoma: Past, present, and future
    • (2001) Ann Surg Oncol , vol.8 , Issue.SUPPL. 9
    • Morton, D.L.1
  • 11
  • 12
    • 0032962081 scopus 로고    scopus 로고
    • Oncological applications of FDG PET imaging: Brain tumors, colorectal cancer, lymphoma and melanoma
    • (1999) J Nucl Med , vol.40 , pp. 591-603
    • Delbeke, D.1
  • 21
    • 0035873999 scopus 로고    scopus 로고
    • Comparison of positron emission tomography scanning and sentinel node biopsy in the detection of micrometastases of primary cutaneous malignant melanoma
    • (2001) J Clin Oncol , vol.19 , pp. 2674-2678
    • Acland, K.M.1    Healy, C.2    Calonje, E.3
  • 36
    • 0035659519 scopus 로고    scopus 로고
    • New developments in PET instrumentation: Quo vadis PET?
    • (2001) J Nucl Med , vol.42 , pp. 1831-1832
    • Knesaurek, K.1
  • 38
    • 0034753439 scopus 로고    scopus 로고
    • Scatter modelling and correction strategies in fully 3-D PET
    • (2001) Nucl Med Commun , vol.22 , pp. 1181-1184
    • Zaidi, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.