메뉴 건너뛰기




Volumn 14, Issue 4, 2002, Pages 225-237

Spline™ implant prospective multicenter study: Interim report on prosthetic screw stability in partially edentulous patients

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CLINICAL TRIAL; DENTURE; EDENTULOUSNESS; FEMALE; HUMAN; INSTRUMENTATION; MALE; MULTICENTER STUDY; PROSPECTIVE STUDY; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 0036043961     PISSN: 14964155     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1708-8240.2002.tb00168.x     Document Type: Article
Times cited : (10)

References (54)
  • 1
    • 0017564248 scopus 로고
    • Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
    • Brånemark P-I, Hansson BO, Adell R, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg 1977; 111(Suppl):1-132.
    • (1977) Scand J Plast Reconstr Surg , vol.111 , pp. 1-132
    • Brånemark, P.-I.1    Hansson, B.O.2    Adell, R.3
  • 3
    • 29644438642 scopus 로고    scopus 로고
    • Improving dental care through mechanical engineering
    • Leary JC, Daher S. Improving dental care through mechanical engineering. Dent Surg Products 1997; 11:30-32.
    • (1997) Dent Surg Products , vol.11 , pp. 30-32
    • Leary, J.C.1    Daher, S.2
  • 4
    • 0031088970 scopus 로고    scopus 로고
    • Comparison of screw retention of nine abutment systems: A pilot study
    • Schulte JK, Coffey J. Comparison of screw retention of nine abutment systems: a pilot study. Implant Dent 1997; 6:28-31.
    • (1997) Implant Dent , vol.6 , pp. 28-31
    • Schulte, J.K.1    Coffey, J.2
  • 5
    • 0026218667 scopus 로고
    • Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup
    • Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 1991; 6:270-276.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 270-276
    • Jemt, T.1
  • 6
    • 0026832538 scopus 로고
    • Failures and complications in 127 consecutively placed fixed partial prostheses supported by Brånemark implants: From prosthetic treatment to first annual checkup
    • Jemt T, Lindén B, Lekholm U. Failures and complications in 127 consecutively placed fixed partial prostheses supported by Brånemark implants: from prosthetic treatment to first annual checkup. Int J Oral Maxillofac Implants 1992; 7:40-44.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 40-44
    • Jemt, T.1    Lindén, B.2    Lekholm, U.3
  • 7
    • 0033302107 scopus 로고    scopus 로고
    • Complications in partially edentulous implant patients: A 5-year retrospective follow-up study of 133 patients supplied with unilateral maxillary prostheses
    • Wennerberg A, Jemt T. Complications in partially edentulous implant patients: a 5-year retrospective follow-up study of 133 patients supplied with unilateral maxillary prostheses. Clin Implant Dent Relat Res 1999; 1:49-56.
    • (1999) Clin Implant Dent Relat Res , vol.1 , pp. 49-56
    • Wennerberg, A.1    Jemt, T.2
  • 8
    • 0031184319 scopus 로고    scopus 로고
    • Implant reconstruction in the posterior mandible: A long-term retrospective study
    • Parein AM, Eckert SE, Wollan PC, Keller EE. Implant reconstruction in the posterior mandible: a long-term retrospective study. J Prosthet Dent 1997; 78:34-42.
    • (1997) J Prosthet Dent , vol.78 , pp. 34-42
    • Parein, A.M.1    Eckert, S.E.2    Wollan, P.C.3    Keller, E.E.4
  • 9
    • 0031254176 scopus 로고    scopus 로고
    • Professional hygiene care, adjustments and complications of mandibular implant-retained overdentures: A three-year retrospective study
    • Den Dunnen ACL, Slagter AP, De Baat C, Kalk W. Professional hygiene care, adjustments and complications of mandibular implant-retained overdentures: a three-year retrospective study. J Prosthet Dent 1997; 78:387-390.
    • (1997) J Prosthet Dent , vol.78 , pp. 387-390
    • Den Dunnen, A.C.L.1    Slagter, A.P.2    De Baat, C.3    Kalk, W.4
  • 10
    • 0028390422 scopus 로고
    • Complications and maintenance requirements for fixed prostheses and overdentures in the edentulous mandible: A 5-year report
    • Hemmings KW, Schmitt A, Zarb GA. Complications and maintenance requirements for fixed prostheses and overdentures in the edentulous mandible: a 5-year report. Int J Oral Maxillofac Implants 1994; 9:191-194.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 191-194
    • Hemmings, K.W.1    Schmitt, A.2    Zarb, G.A.3
  • 11
    • 0027015903 scopus 로고
    • A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects
    • Naert I, Quirynen M, van Steenberghe D, Darius P. A study of 589 consecutive implants supporting complete fixed prostheses. Part II: prosthetic aspects. J Prosthet Dent 1992; 68:949-956.
    • (1992) J Prosthet Dent , vol.68 , pp. 949-956
    • Naert, I.1    Quirynen, M.2    Van Steenberghe, D.3    Darius, P.4
  • 12
    • 0033193655 scopus 로고    scopus 로고
    • Survival of the Brånemark implant in partially edentulous jaws: A 10-year prospective multicenter study
    • Lekholm U, Gunne J, Henry P, et al. Survival of the Brånemark implant in partially edentulous jaws: a 10-year prospective multicenter study. Int J Oral Maxillofac Implants 1999; 14:639-645.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 639-645
    • Lekholm, U.1    Gunne, J.2    Henry, P.3
  • 13
    • 0032040167 scopus 로고    scopus 로고
    • Retrospective review of 1170 endosseous implants placed in partially edentulous jaws
    • Eckert SE, Wollan PC. Retrospective review of 1170 endosseous implants placed in partially edentulous jaws. J Prosthet Dent 1998; 79:415-421.
    • (1998) J Prosthet Dent , vol.79 , pp. 415-421
    • Eckert, S.E.1    Wollan, P.C.2
  • 14
    • 0034220576 scopus 로고    scopus 로고
    • Five-year results with fixed complete-arch mandibular prostheses supported by 4 implants
    • Eliasson A, Palmqvist S, Svenson B, Sondell K. Five-year results with fixed complete-arch mandibular prostheses supported by 4 implants. Int J Oral Maxillofac Implants 2000; 15:505-510.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 505-510
    • Eliasson, A.1    Palmqvist, S.2    Svenson, B.3    Sondell, K.4
  • 15
    • 0028950513 scopus 로고
    • Reconstruction of the severely atrophic edentulous mandible with endosseous implants: A 10-year longitudinal study
    • Keller EE. Reconstruction of the severely atrophic edentulous mandible with endosseous implants: a 10-year longitudinal study. J Oral Maxillofac Surg 1985; 53:305-320.
    • (1985) J Oral Maxillofac Surg , vol.53 , pp. 305-320
    • Keller, E.E.1
  • 16
    • 0025493944 scopus 로고
    • Applicability of osseointegrated oral implants in the rehabilitation of partial edentulism: A prospective multicenter study on 558 fixtures
    • van Steenberghe D, Lekholm U, Bolender C, et al. Applicability of osseointegrated oral implants in the rehabilitation of partial edentulism: a prospective multicenter study on 558 fixtures. Int J Oral Maxillofac Implants 1990; 5:272-281.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 272-281
    • Van Steenberghe, D.1    Lekholm, U.2    Bolender, C.3
  • 17
    • 0031230778 scopus 로고    scopus 로고
    • The DIA abutment system and telescopic prosthesis: A clinical report
    • Prieskel HW, Tsolka P. The DIA abutment system and telescopic prosthesis: a clinical report. Int J Oral Maxillofac Implants 1997; 12:628-633.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 628-633
    • Prieskel, H.W.1    Tsolka, P.2
  • 20
    • 0029268937 scopus 로고
    • Evaluation of machining accuracy and consistency of selected implants, standard abutments, and laboratory analogs
    • Binon PP. Evaluation of machining accuracy and consistency of selected implants, standard abutments, and laboratory analogs. Int J Prosthodont 1995; 8:162-178.
    • (1995) Int J Prosthodont , vol.8 , pp. 162-178
    • Binon, P.P.1
  • 21
    • 0029377916 scopus 로고
    • Comparison of screw loosening, rotation, and deflection among three implants designs
    • Dixon DI, Breeding LC, Sadler JP, McKay ML. Comparison of screw loosening, rotation, and deflection among three implants designs. J Prosthet Dent 1995; 74:270-278.
    • (1995) J Prosthet Dent , vol.74 , pp. 270-278
    • Dixon, D.I.1    Breeding, L.C.2    Sadler, J.P.3    McKay, M.L.4
  • 23
    • 0038843139 scopus 로고
    • A comparison of three mechanical properties of four implant designs
    • Nicholls JI, Basten CH-J. A comparison of three mechanical properties of four implant designs. Postgrad Dent 1995; 2:4-12.
    • (1995) Postgrad Dent , vol.2 , pp. 4-12
    • Nicholls, J.I.1    Basten, C.-J.2
  • 24
    • 0141737437 scopus 로고    scopus 로고
    • The evolution and evaluation of two interference-fit implant interfaces
    • Binon PP. The evolution and evaluation of two interference-fit implant interfaces. Postgrad Dent 1996; 3:3-13.
    • (1996) Postgrad Dent , vol.3 , pp. 3-13
    • Binon, P.P.1
  • 25
    • 0031134265 scopus 로고    scopus 로고
    • Load factor control for implants in the posterior partially edentulous segment
    • Rangert BR, Sullivan RM, Jemt TM. Load factor control for implants in the posterior partially edentulous segment. Int J Oral Maxillofac Implants 1997; 12:360-370.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 360-370
    • Rangert, B.R.1    Sullivan, R.M.2    Jemt, T.M.3
  • 26
    • 0027829234 scopus 로고
    • Nonlinear finite element contact analysis of dental implant components
    • Sakaguchi RL, Borgensen SE. Nonlinear finite element contact analysis of dental implant components. Int J Oral Maxillofac Implants 1993; 8:655-661.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 655-661
    • Sakaguchi, R.L.1    Borgensen, S.E.2
  • 28
    • 0024150129 scopus 로고
    • Single tooth rehabilitation using osseointegration. A modified surgical and prosthodontic approach
    • Öhrnell L-O, Hirsch J, Ericsson I, Brånemark P-I. Single tooth rehabilitation using osseointegration. A modified surgical and prosthodontic approach. Quintessence Int 1988; 19:871-876.
    • (1988) Quintessence Int , vol.19 , pp. 871-876
    • Öhrnell, L.-O.1    Hirsch, J.2    Ericsson, I.3    Brånemark, P.-I.4
  • 30
    • 0029267535 scopus 로고
    • Reverse torque failure of screw-shape implants in baboons: Baseline data for abutment torque application
    • Carr AB, Larsen PE, Papazoglou E, McGlumphy E. Reverse torque failure of screw-shape implants in baboons: baseline data for abutment torque application. Int J Oral Maxillofac Implants 1995; 10:167-174.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 167-174
    • Carr, A.B.1    Larsen, P.E.2    Papazoglou, E.3    McGlumphy, E.4
  • 31
    • 0026829920 scopus 로고
    • Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants
    • Patterson EA, Johns RB. Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants. Int J Oral Maxillofac Implants 1992; 7:26-34.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 26-34
    • Patterson, E.A.1    Johns, R.B.2
  • 32
    • 0026921977 scopus 로고
    • Loads and designs of screw joints for single crowns supported by osseointegrated implants
    • Jörnéus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992; 7:353-359.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 353-359
    • Jörnéus, L.1    Jemt, T.2    Carlsson, L.3
  • 33
    • 0028390316 scopus 로고
    • Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years
    • Kallus T, Bessing C. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 1994; 9:169-178.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 169-178
    • Kallus, T.1    Bessing, C.2
  • 34
    • 0030227099 scopus 로고    scopus 로고
    • The spline implant: Design, engineering, and evaluation
    • Binon PP. The spline implant: design, engineering, and evaluation. Int J Prosthodont 1996; 9:419-433.
    • (1996) Int J Prosthodont , vol.9 , pp. 419-433
    • Binon, P.P.1
  • 35
    • 0024773086 scopus 로고
    • Recognition of malignancy and dysplasia in the dental implant patient
    • Smith RA, Silverman S Jr, Auclert O. Recognition of malignancy and dysplasia in the dental implant patient. J Oral Implantol 1989; 15:255-258.
    • (1989) J Oral Implantol , vol.15 , pp. 255-258
    • Smith, R.A.1    Silverman, S.2    Auclert, O.3
  • 36
    • 0021233997 scopus 로고
    • The effect of cigarette smoking on skin-flap survival in the face lift patient
    • Rees TD, Liverett DM, Guy CL. The effect of cigarette smoking on skin-flap survival in the face lift patient. Plast Reconstr Surg 1984; 73:911-915.
    • (1984) Plast Reconstr Surg , vol.73 , pp. 911-915
    • Rees, T.D.1    Liverett, D.M.2    Guy, C.L.3
  • 37
    • 0028431622 scopus 로고
    • Tobacco as a risk factor
    • Bergström J, Preber H. Tobacco as a risk factor. J Periodontol 1994; 65(Suppl):545-550.
    • (1994) J Periodontol , vol.65 , pp. 545-550
    • Bergström, J.1    Preber, H.2
  • 38
    • 0031136203 scopus 로고    scopus 로고
    • Effects of smoking and smoking cessation on healing after mechanical periodontal therapy
    • Grossi SG, Zambon J, Machtei EE, et al. Effects of smoking and smoking cessation on healing after mechanical periodontal therapy. J Am Dent Assoc 1997; 128:599-607.
    • (1997) J Am Dent Assoc , vol.128 , pp. 599-607
    • Grossi, S.G.1    Zambon, J.2    Machtei, E.E.3
  • 39
    • 0030344819 scopus 로고    scopus 로고
    • The relationship of smoking on peri-implant tissue: A retrospective study
    • Haas R, Haimböck W, Mailath G, Watzek G. The relationship of smoking on peri-implant tissue: a retrospective study. J Prosthet Dent 1996; 76:592-596.
    • (1996) J Prosthet Dent , vol.76 , pp. 592-596
    • Haas, R.1    Haimböck, W.2    Mailath, G.3    Watzek, G.4
  • 40
    • 0027792944 scopus 로고
    • The association between the failure of dental implants and cigarette smoking
    • Bain CA, Moy PK. The association between the failure of dental implants and cigarette smoking. Int J Oral Maxillofac Implants 1993; 8:609-615.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 609-615
    • Bain, C.A.1    Moy, P.K.2
  • 41
    • 0028506482 scopus 로고
    • The effect of smoking on implant survival at second-stage surgery: DICRG Interim Report No. 5
    • Gorman LM, Lambert PM, Morris HF, Ochi S, Winkler S. The effect of smoking on implant survival at second-stage surgery: DICRG Interim Report No. 5. Implant Dent 1994; 3:165-168.
    • (1994) Implant Dent , vol.3 , pp. 165-168
    • Gorman, L.M.1    Lambert, P.M.2    Morris, H.F.3    Ochi, S.4    Winkler, S.5
  • 42
    • 0028685928 scopus 로고
    • The effect of smoking on early implant failure
    • De Bruyn H, Collaert B. The effect of smoking on early implant failure. Clin Oral Implants Res 1994; 5:260-264.
    • (1994) Clin Oral Implants Res , vol.5 , pp. 260-264
    • De Bruyn, H.1    Collaert, B.2
  • 43
    • 0030277222 scopus 로고    scopus 로고
    • Smoking and implant failure: A smoking cessation protocol
    • Bain CA. Smoking and implant failure: a smoking cessation protocol. Int J Oral Maxillofac Implants 1996; 11:756-759.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 756-759
    • Bain, C.A.1
  • 44
    • 0347855737 scopus 로고
    • Diagnosis, treatment planning, and the sequencing of treatment for implant reconstructive procedures
    • Schnitman PA. Diagnosis, treatment planning, and the sequencing of treatment for implant reconstructive procedures. Alpha Omegan 1987; 80:32-35.
    • (1987) Alpha Omegan , vol.80 , pp. 32-35
    • Schnitman, P.A.1
  • 45
    • 0029417992 scopus 로고
    • Radiographic modalities for diagnosis and treatment planning in implant dentistry
    • Garg AK, Vicari A. Radiographic modalities for diagnosis and treatment planning in implant dentistry. Implant Soc 1995; 5:7-11.
    • (1995) Implant Soc , vol.5 , pp. 7-11
    • Garg, A.K.1    Vicari, A.2
  • 46
    • 0020776467 scopus 로고
    • Biomechanical considerations in osseointegrated prostheses
    • Skalak R. Biomechanical considerations in osseointegrated prostheses. J Prosthet Dent 1983; 49:843-848.
    • (1983) J Prosthet Dent , vol.49 , pp. 843-848
    • Skalak, R.1
  • 48
    • 0027563662 scopus 로고
    • Full-arch implant framework casting accuracy. Preliminary in vitro observation for in vivo testing
    • Carr AB, Stewart RB. Full-arch implant framework casting accuracy. Preliminary in vitro observation for in vivo testing. J Prosthodont 1992; 2:2-8.
    • (1992) J Prosthodont , vol.2 , pp. 2-8
    • Carr, A.B.1    Stewart, R.B.2
  • 49
    • 0031301642 scopus 로고    scopus 로고
    • Fit of implant frameworks fabricated by different techniques
    • Riedy SJ, Lang BR, Lang BE. Fit of implant frameworks fabricated by different techniques. J Prosthet Dent 1997; 78:596-604.
    • (1997) J Prosthet Dent , vol.78 , pp. 596-604
    • Riedy, S.J.1    Lang, B.R.2    Lang, B.E.3
  • 50
    • 0346664512 scopus 로고
    • Accuracy of fixed partial dentures made by various soldering techniques and one-piece castings
    • Fusayama T, Wakumoto S, Hosada H. Accuracy of fixed partial dentures made by various soldering techniques and one-piece castings. J Prosthet Dent 1964; 14:334-342.
    • (1964) J Prosthet Dent , vol.14 , pp. 334-342
    • Fusayama, T.1    Wakumoto, S.2    Hosada, H.3
  • 51
    • 0033628712 scopus 로고    scopus 로고
    • Implants and components: Entering the new millennium
    • Binon PP. Implants and components: entering the new millennium. Int Oral Maxillofac Implants 2000; 15:76-94.
    • (2000) Int Oral Maxillofac Implants , vol.15 , pp. 76-94
    • Binon, P.P.1
  • 52
    • 0033106741 scopus 로고    scopus 로고
    • A technique for compensating for the loose CeraOne screw
    • Krumholz ML. A technique for compensating for the loose CeraOne screw. Int J Periodontics Restorative Dent 1999; 19:183-187.
    • (1999) Int J Periodontics Restorative Dent , vol.19 , pp. 183-187
    • Krumholz, M.L.1
  • 53
    • 0027357731 scopus 로고
    • The biomechanics of force distribution in implant-supported prostheses
    • Weinberg LA. The biomechanics of force distribution in implant-supported prostheses. Int J Oral Maxillofac Implants 1993; 8:19-31.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 19-31
    • Weinberg, L.A.1
  • 54
    • 0029366883 scopus 로고
    • A comparison of implant/prosthesis loading with four clinical variables
    • Weinberg LA, Kruger B. A comparison of implant/prosthesis loading with four clinical variables. Int J Prosthodont 1995; 8:421-433.
    • (1995) Int J Prosthodont , vol.8 , pp. 421-433
    • Weinberg, L.A.1    Kruger, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.