메뉴 건너뛰기




Volumn 4684 I, Issue , 2002, Pages 167-178

Segmentation of 830 nm and 1310 nm lasik corneal optical coherence tomography images

Author keywords

Active contour model; Deconvolution; Image segmentation; Morphological operation; Optical coherence tomography; Speckle suppression

Indexed keywords

ALGORITHMS; COHERENT LIGHT; LIGHT ABSORPTION; MATHEMATICAL MODELS; TISSUE; TOMOGRAPHY;

EID: 0036035475     PISSN: 0277786X     EISSN: None     Source Type: Journal    
DOI: 10.1117/12.467123     Document Type: Article
Times cited : (16)

References (23)
  • 1
    • 0026254046 scopus 로고
    • Optical coherence tomography
    • D. Huang, E.A. Swanson, et al., "Optical coherence tomography," Science, 254(5035): pp1178-1181, 1991.
    • (1991) Science , vol.254 , Issue.5035 , pp. 1178-1181
    • Huang, D.1    Swanson, E.A.2
  • 2
    • 0027985314 scopus 로고
    • Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography
    • J.A. Izatt, M.R. Hee, et al., "Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography," Arch Ophthalmol 112(12): pp1584-1589, 1994.
    • (1994) Arch Ophthalmol , vol.112 , Issue.12 , pp. 1584-1589
    • Izatt, J.A.1    Hee, M.R.2
  • 3
    • 0345515978 scopus 로고    scopus 로고
    • Regression after LASIK for the treatment of myopia: The role of the corneal epithelium
    • C.P. Lohmann, J.L. Guell, "Regression after LASIK for the treatment of myopia: the role of the corneal epithelium." Semin Ophthalmol, 13(2): pp79-82, 1998.
    • (1998) Semin Ophthalmol , vol.13 , Issue.2 , pp. 79-82
    • Lohmann, C.P.1    Guell, J.L.2
  • 4
    • 0033959899 scopus 로고    scopus 로고
    • Evaluation of corneal flap dimensions and cut quality using the automated corneal shaper microkeratome
    • A. Behrens, B. Seitz, et al., "Evaluation of corneal flap dimensions and cut quality using the Automated Corneal Shaper microkeratome." J Refract Surg, 16(1): pp83-89, 2000.
    • (2000) J Refract Surg , vol.16 , Issue.1 , pp. 83-89
    • Behrens, A.1    Seitz, B.2
  • 5
    • 0033504309 scopus 로고    scopus 로고
    • Very high-frequency ultrasound corneal analysis identifies anatomic correlates of optical complications of lamellar refractive surgery: Anatomic diagnosis in lamellar surgery
    • D.Z. Reinstein, R.H. Silverman, et al., "Very high-frequency ultrasound corneal analysis identifies anatomic correlates of optical complications of lamellar refractive surgery: anatomic diagnosis in lamellar surgery," Ophthalmology, 106(3): pp474-82, 1999.
    • (1999) Ophthalmology , vol.106 , Issue.3 , pp. 474-482
    • Reinstein, D.Z.1    Silverman, R.H.2
  • 6
    • 0031779852 scopus 로고    scopus 로고
    • Iatrogenic keratectasia after laser in situ keratomileusis
    • T. Seiler, K. Koufala, et al., "Iatrogenic keratectasia after laser in situ keratomileusis," J Refract Surg, 14(3): pp312-317, 1998.
    • (1998) J Refract Surg , vol.14 , Issue.3 , pp. 312-317
    • Seiler, T.1    Koufala, K.2
  • 7
    • 0031813262 scopus 로고    scopus 로고
    • Iatrogenic keratectasia after LASIK in a case of forme fruste keratoconus
    • T. Seiler, A.W. Quurke, "Iatrogenic keratectasia after LASIK in a case of forme fruste keratoconus," J Cataract Refract Surg, 24(7): pp1007-1009, 1998.
    • (1998) J Cataract Refract Surg , vol.24 , Issue.7 , pp. 1007-1009
    • Seiler, T.1    Quurke, A.W.2
  • 8
    • 0034038860 scopus 로고    scopus 로고
    • Optical coherence tomography evaluation of the corneal cap and stromal bed features after laser in situ keratomileusis for high myopia and astigmatism
    • discussion pp88
    • M.J. Maldonado, L. Ruiz-Oblitas, et al., "Optical coherence tomography evaluation of the corneal cap and stromal bed features after laser in situ keratomileusis for high myopia and astigmatism," Ophthalmology, 107(1): pp81-7; discussion pp88, 2000.
    • (2000) Ophthalmology , vol.107 , Issue.1 , pp. 81-87
    • Maldonado, M.J.1    Ruiz-Oblitas, L.2
  • 10
    • 0031915674 scopus 로고    scopus 로고
    • Investigation of dispersion effects in ocular media by multiple wavelength partial coherence interferometry
    • W. Drexler, C.K. Hitzenberger, et al., "Investigation of dispersion effects in ocular media by multiple wavelength partial coherence interferometry," Exp Eye Res, 66, pp. 25-33, 1998.
    • (1998) Exp Eye Res , vol.66 , pp. 25-33
    • Drexler, W.1    Hitzenberger, C.K.2
  • 11
    • 4043126029 scopus 로고    scopus 로고
    • In vivo video rate optical coherence tomography
    • A.M. Rollins, M.D. Kulkarni, et al., "In vivo video rate optical coherence tomography," Opt Express, 3, pp. 219-229, 1998.
    • (1998) Opt Express , vol.3 , pp. 219-229
    • Rollins, A.M.1    Kulkarni, M.D.2
  • 12
    • 0000150646 scopus 로고    scopus 로고
    • Optimal interferometer designs for optical coherence tomography
    • A.M. Rollins, J.A. Izatt, "Optimal interferometer designs for optical coherence tomography," Opt Lett., 24, pp. 1484-1486, 1999.
    • (1999) Opt Lett. , vol.24 , pp. 1484-1486
    • Rollins, A.M.1    Izatt, J.A.2
  • 13
    • 0034899732 scopus 로고    scopus 로고
    • Real-time optical coherence tomography of the anterior segment at 1310 nm
    • S. Radhakrishnan, A.M. Rollins, "Real-time optical coherence tomography of the anterior segment at 1310nm," Arch Ophthalmol., 119, pp. 1179-1185, 2001.
    • (2001) Arch Ophthalmol. , vol.119 , pp. 1179-1185
    • Radhakrishnan, S.1    Rollins, A.M.2
  • 14
    • 0003492957 scopus 로고    scopus 로고
    • ANSI Z 136.1-2000. Orlando, Fla: Laser Institute of America
    • American National Standards Institute. American National Standard for Safe use of Lasers, ANSI Z 136.1-2000. Orlando, Fla: Laser Institute of America, pp. 45-49, 2000.
    • (2000) American National Standard for Safe use of Lasers , pp. 45-49
  • 15
    • 0027699308 scopus 로고
    • In vivo retinal imaging by optical coherence tomography
    • E.A. Swanson, J.A. Izatt, et al., "In vivo retinal imaging by optical coherence tomography," Optics Letters, 18, pp. 1864-1866, 1993.
    • (1993) Optics Letters , vol.18 , pp. 1864-1866
    • Swanson, E.A.1    Izatt, J.A.2
  • 17
    • 0031675860 scopus 로고    scopus 로고
    • Restoration of optical coherence images of living tissue using the CLEAN algorithm
    • J.M. Schmitt, "Restoration of optical coherence images of living tissue using the CLEAN algorithm," Journal of Biomedical Optics, 3, pp. 66-75, 1998.
    • (1998) Journal of Biomedical Optics , vol.3 , pp. 66-75
    • Schmitt, J.M.1
  • 18
    • 0002757556 scopus 로고    scopus 로고
    • Deconvolution and enhancement of optical coherence tomograms
    • J.M. Schmitt, Z. Liang, "Deconvolution and enhancement of optical coherence tomograms," SPIE, vol. 2981, pp. 46-57, 1997.
    • (1997) SPIE , vol.2981 , pp. 46-57
    • Schmitt, J.M.1    Liang, Z.2
  • 22
    • 0031191150 scopus 로고    scopus 로고
    • Image enhancement in optical coherence tomography using deconvolution
    • M.D. Kulkarni, C.W. Thomas, J.A. Izatt, "Image enhancement in optical coherence tomography using deconvolution," Electronics Letters, 33, pp. 1365-1367, 1997.
    • (1997) Electronics Letters , vol.33 , pp. 1365-1367
    • Kulkarni, M.D.1    Thomas, C.W.2    Izatt, J.A.3
  • 23
    • 0010704125 scopus 로고
    • Image processing of images from peripheral-artery digital subtraction angiography studies
    • Bellingham, Washionton
    • D.L. Wilson, L.R. Tarbox LR, et al., "Image processing of images from peripheral-artery digital subtraction angiography studies," In proceedings of SPIE Medical Imaging II, Bellingham, Washionton, pp. 765-771, 1988.
    • (1988) Proceedings of SPIE Medical Imaging II , pp. 765-771
    • Wilson, D.L.1    Tarbox, L.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.