메뉴 건너뛰기




Volumn 4684 I, Issue , 2002, Pages 237-248

Effects of uncertainty in camera geometry on three-dimensional catheter reconstruction from biplane fluoroscopic images

Author keywords

3 D reconstruction; Biplane images; Camera geometry; Uncertainty

Indexed keywords

CATHETERS; COMPUTER SIMULATION; ELECTRODES; PARAMETER ESTIMATION; X RAY ANALYSIS; X RAYS;

EID: 0036033754     PISSN: 0277786X     EISSN: None     Source Type: Journal    
DOI: 10.1117/12.467163     Document Type: Article
Times cited : (5)

References (11)
  • 1
    • 0033746345 scopus 로고    scopus 로고
    • Online geometrical calibration of a mobile C-arm using external sensors
    • Medical Imaging 2000: Image Display and Visualization, Seong K. Mun, Editor
    • Mitschke M.M., Navab N., and Schutz O., "Online geometrical calibration of a mobile C-arm using external sensors," Medical Imaging 2000: Image Display and Visualization, Seong K. Mun, Editor, Proceedings of SPIE Vol. 3976, pp. 580-587, 2000.
    • (2000) Proceedings of SPIE , vol.3976 , pp. 580-587
    • Mitschke, M.M.1    Navab, N.2    Schutz, O.3
  • 3
    • 0027637986 scopus 로고
    • Geometrical calibration of x-ray imaging chains for three-dimensional reconstruction
    • Rougee A., Picard C., Ponchut C., and Trousset Y., "Geometrical calibration of x-ray imaging chains for three-dimensional reconstruction," Computerized Medical Imaging and Graphics, Vol. 17, Nos. 4/5, pp. 295-300, 1993.
    • (1993) Computerized Medical Imaging and Graphics , vol.17 , Issue.4-5 , pp. 295-300
    • Rougee, A.1    Picard, C.2    Ponchut, C.3    Trousset, Y.4
  • 4
    • 0013177078 scopus 로고    scopus 로고
    • Machine precision assessment for 3-D/2-D digital subtracted angiography images registration
    • SPIE conference on Image Processing
    • Kerrien E., Vaillant R., Launay L., Berger M., Maurincomme E., and Picard L., "Machine precision assessment for 3-D/2-D digital subtracted angiography images registration," SPIE conference on Image Processing, SPIE Vol. 3338, pp. 39-49, 1998.
    • (1998) SPIE , vol.3338 , pp. 39-49
    • Kerrien, E.1    Vaillant, R.2    Launay, L.3    Berger, M.4    Maurincomme, E.5    Picard, L.6
  • 5
    • 0025245537 scopus 로고
    • Propagation and reduction of error in three-dimensional structure determined from biplane views of unknown orientation
    • Fencil L.E., and Metz C.E., "Propagation and reduction of error in three-dimensional structure determined from biplane views of unknown orientation," Med. Phys. 17 (6), pp. 951-961, 1990.
    • (1990) Med. Phys. , vol.17 , Issue.6 , pp. 951-961
    • Fencil, L.E.1    Metz, C.E.2
  • 6
    • 0029089471 scopus 로고
    • Determination of 3-D imaging geometry and object configurations from two biplane views: An enhancement of the metz-fencil technique
    • Hoffman K.R., Metz C.E., and Chen Y., "Determination of 3-D imaging geometry and object configurations from two biplane views: an enhancement of the Metz-Fencil technique," Med. Phys. 22 (8), pp. 1219-1227, 1995.
    • (1995) Med. Phys. , vol.22 , Issue.8 , pp. 1219-1227
    • Hoffman, K.R.1    Metz, C.E.2    Chen, Y.3
  • 7
    • 0029327157 scopus 로고
    • Assessment of diffuse coronary artery disease by quantitative analysis of coronary morphology based upon 3-D reconstruction from biplane angiograms
    • Wahle A., Wellnhofer E., Mugargu I., Saiuer H.U., Oswald H., and Fleck E., "Assessment of diffuse coronary artery disease by quantitative analysis of coronary morphology based upon 3-D reconstruction from biplane angiograms," IEEE Transactions on Medical Imaging, Vol. 14, No. 2, pp. 230-241, 1995.
    • (1995) IEEE Transactions on Medical Imaging , vol.14 , Issue.2 , pp. 230-241
    • Wahle, A.1    Wellnhofer, E.2    Mugargu, I.3    Saiuer, H.U.4    Oswald, H.5    Fleck, E.6
  • 9
    • 0022712534 scopus 로고
    • Mathematical tools for spatial computations with biplane isocentric x-ray equipment
    • Wollschlager H., Lee P., Zeiher A., Solzbach U., Bonzel T., and Just H., "Mathematical tools for spatial computations with biplane isocentric x-ray equipment," Biomed. Technik, 31, pp. 101-106, 1986.
    • (1986) Biomed. Technik , vol.31 , pp. 101-106
    • Wollschlager, H.1    Lee, P.2    Zeiher, A.3    Solzbach, U.4    Bonzel, T.5    Just, H.6
  • 10
    • 0029463591 scopus 로고
    • Correction of image intensifier distortion for three-dimensional x-ray angiography
    • Schueler B., and Hu X. "Correction of image intensifier distortion for three-dimensional x-ray angiography," SPIE, Vol. 2432, 1995, pp. 272-279.
    • (1995) SPIE , vol.2432 , pp. 272-279
    • Schueler, B.1    Hu, X.2
  • 11
    • 0025907199 scopus 로고
    • Analysis and correction of imperfections in the image intensifier-TV-digitizer imaging chain
    • Boone J.M., Seibert J.A., Barrett W.A., and Blood E.A. "Analysis and correction of imperfections in the image intensifier-TV-digitizer imaging chain," Med. Phys. 18 (2), 1991, pp. 236-242.
    • (1991) Med. Phys. , vol.18 , Issue.2 , pp. 236-242
    • Boone, J.M.1    Seibert, J.A.2    Barrett, W.A.3    Blood, E.A.4