Volumn 4682, Issue , 2002, Pages 755-763

Development of x-ray detector for Multislice CT with 0.5 mm slice thickness and 0.5 second revolution

Author keywords

Detectors; Multi slice CT; Scintillators

Indexed keywords

COMPUTERIZED TOMOGRAPHY; LIGHT TRANSMISSION; PHOSPHORS; RADIATION DAMAGE; X RAYS;

EID: 0036033617     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.465624     Document Type: Conference Paper
Times cited : (3)

References (12)
  • 2
    • 0001839273 scopus 로고    scopus 로고
    • Multislice X-ray CT scanner
    • Y. Saito, "Multislice X-ray CT Scanner," Medical Review, 66, pp. 1-8, 1998.
    • (1998) Medical Review , vol.66 , pp. 1-8
    • Saito, Y.1
  • 4
    • 0005113371 scopus 로고    scopus 로고
    • Jpn. Patent Disclosure S58-204088, 1983 (Appl. May 21 1982)
    • K. Yokota, Jpn. Patent Disclosure S58-204088, 1983 (Appl. May 21 1982); N. Matsuda, K. Yokota, and M. Tamatani, "Praseodymium-doped gadolinium oxysulfide ceramics prepared by the hot isostatic pressing process," Electrochem. Soc. Fall Meeting, Honolulu, Abstr. No. 1870RNP, 1987.
    • Yokota, K.1
  • 5
    • 0005157016 scopus 로고
    • Praseodymium-doped gadolinium oxysulfide ceramics prepared by the hot isostatic pressing process
    • Honolulu, Abstr. No. 1870RNP
    • K. Yokota, Jpn. Patent Disclosure S58-204088, 1983 (Appl. May 21 1982); N. Matsuda, K. Yokota, and M. Tamatani, "Praseodymium-doped gadolinium oxysulfide ceramics prepared by the hot isostatic pressing process," Electrochem. Soc. Fall Meeting, Honolulu, Abstr. No. 1870RNP, 1987.
    • (1987) Electrochem. Soc. Fall Meeting
    • Matsuda, N.1    Yokota, K.2    Tamatani, M.3
  • 7
    • 0041894868 scopus 로고    scopus 로고
    • Properties and application of gadolinium oxysulfide based ceramic scintillators
    • Boston, Abstr. No. 879
    • W. Rossner and M. Ostertag, "Properties and application of gadolinium oxysulfide based ceramic scintillators," Electrochem., Soc. Fall Meeting, Boston, Abstr. No. 879, 1998.
    • (1998) Electrochem., Soc. Fall Meeting
    • Rossner, W.1    Ostertag, M.2
  • 10
    • 0005191238 scopus 로고    scopus 로고
    • Evaluation of low contrast resolution using contrast-to-noise ratio in CT
    • Y. Mizuno, "Evaluation of Low Contrast Resolution Using Contrast-to-noise Ratio in CT," Jpn. J. Radiol. Technol., 55 p. 778. 1999.
    • (1999) Jpn. J. Radiol. Technol. , vol.55 , pp. 778
    • Mizuno, Y.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.